C
AREFREE OF
C
OLORADO
I
NSTALLATION
M
ANUAL
OEM
A
SCENT
SC
&
SS
052553-011r6
6
I
NSTALLING THE
D
EFLECTOR
-
O
PTION
2,
W
/
B
RACKETS
The following instructions reference the preliminary layout done previously. Refer to "Option 2 - Case
Mount w/ Brackets" on page 2.
Figure 7. Mounting the Deflector w/ Brackets.
1. Position the brackets on the room face as shown.
For rooms with box lengths
42" - 114", qty = 2; for lengths 115" - 197", qty = 3; for lengths 198" – 289",
qty = 4; for lengths 290 and longer, qty = 5.
2. Using a quality silicone sealant, coat the mounting surface of the bracket with particular attention
around the mounting holes.
3. Attach the bracket using five (5) #12 x 1 self-drilling screws each. The slot is not for a mounting screw.
4. (Detail A) Lift and set the groove in the back of the deflector onto the hook of the brackets.
5. Horizontally center the case over the room.
6. In the lowest screw groove, attach the deflector to the brackets using the #12 x 1/2 self-drilling TEK
screws (3 per bracket).
as011b
Bracket Cover
DETAIL
B
4" min, 12" max (typ)
Units Up to 114" - 2 Brackets
Units 290" and Longer - 5 Brackets
Evenly Space
Evenly Space
#12 x 1/2
Self Drilling Screw
(3 per bracket)
4" min, 12" max (typ)
#12 x 1
Self Drilling Screw
(5 per bracket)
4" min, 12" max (typ)
Units 115" thru 197" - 3 Brackets
4" min, 12" max (typ)
Units 198" thru 289" - 4 Brackets
Evenly Space
Screws Shown
Are Typical For
All Brackets
Do Not Use Slots
for Mounting Screws
Centerline of
Room
Centerline of
Room
1" (typ)
1" (typ)
1" (typ)
1" (typ)
Bracket (ref)
Deflector (ref)
DETAIL
A
7.5"-8.5"
(ref)