12

 

 

4.  The open dialog box will pop up.  Navigate to the zip file 

containing the new sounds.  Note:  Only a file name with 

matching serial number is compatible with the connected 

device.  Select the file and click open. 

5.  The files are extracted and saved to the device.  Large libraries 

will take longer to download than short ones.  This step may 

take some time to complete. 

6.  Once the sounds are downloaded a pop-up message will 

appear.  Click okay.  The new sound or sounds will be 

permanently visible in the Library pane and ready for use. 

SimScope Wi-Fi Configuration 

SimScope with Wi-Fi capability require information regarding the wireless 

environment before use.  The default settings that come preloaded from 

factory (see Figure 2) are common to most networks except for the 

SSID, pass phrase and possibly the security/authentication setting.  In 

some cases, it may be easier to refer the Wi-Fi setup to a network 

administrator.  Obtain the SSID and pass phrase of the wireless network 

before proceeding.  Note:  A SimScope supplied with a Bionic Hybrid 

Simulator system is already configured to work with the Bionic Hybrid 

Simulator.  No setup is necessary. 

1.  Run the SimScope PC application on a computer connected to 

the network. 

2.  Connect the SimScope to the PC using the USB cable. 
3.  After the PC application displays “SimScope ready” click the 

 icon to display the Wi-Fi configuration window. 

Only fill in the network settings located under the SimScope Wi-Fi 

Configuration heading (right column).  Refer to Table 2 on page 13 for 

explanations on each setting.  In some cases, updating the SSID and 

pass phrase first while leaving the rest of the settings to default is the 

best approach.  Refer to Figure 2 on page 13 as an example. 

4.  Make sure that the check box “Enable Wi-Fi Module” is 

checked.  Click the “Save” button to save settings. 

5.  Click the “Test” button to test the Wi-Fi settings.  A message will 

appear in the bottom-left corner indicating pass or fail.  If the 

test fails, verify the settings and try again. 

Summary of Contents for SimScope

Page 1: ......

Page 2: ...he SimScope with new sounds 11 SimScope Wi Fi Configuration 12 Wi Fi Configuration Window SimScope 13 Wi Fi Configuration Window PC Application 17 Standardized Patient SAM PAT Basic Manikins 18 SimShi...

Page 3: ...e ear tips for secure fit Do not use if missing or loose Place patches on healthy skin Do not place over sores or cuts Excessive body hair may make removal uncomfortable Use only AAA alkaline batterie...

Page 4: ...ulator To get up and running quickly perform the following steps Software Installation Software supplied is designed to work with Microsoft Windows 7 and newer operating systems If the purchase is sup...

Page 5: ...r for each USB port on the computer If the wizard does not appear skip to step 6 2 Click No not at this time and click next 3 Click install auto 4 Click finished 5 If asked to restart click Later 6 De...

Page 6: ...he sound assigned to that site is played For controls there are two volume buttons located on the chest piece labeled plus and minus Turning On and Off To turn the SimScope on press any volume key loc...

Page 7: ...e useful for verifying correct tag placements on a standardized patient or learning the different heart locations on a manikin If desired this feature can be disabled through the SimScope PC software...

Page 8: ...h Pack for approximately 12 hours When the batteries are near completion the Tech Pack will blink red The batteries can be recharged using the Cardionics supplied charger When the Tech Pack is connect...

Page 9: ...r to connect with a Wi Fi access point or an access point of a Bionic Hybrid Simulator SimScope Drop Down Box Displays the current device serial number Clicking the drop down arrow lists other devices...

Page 10: ...at takes place in the PC App Stop Log Stops recording activity to the log file Insert Note Allows the user to insert notes into an active log file Clicking the logo will open the Cardionics On Line Le...

Page 11: ...lay sounds defined by the patch rather than sounds assigned by the user Patches are typically special ordered and tailored per customer specifications During power up the SimScope will play the voice...

Page 12: ...me access point or Wi Fi network Includes friendly name of the device playing status IP address and current battery voltage Status Bar Bottom left displays the status of the PC App Provides informatio...

Page 13: ...network administrator Obtain the SSID and pass phrase of the wireless network before proceeding Note A SimScope supplied with a Bionic Hybrid Simulator system is already configured to work with the B...

Page 14: ...ation Functions Name Function Band Frequency band or spectrum Two options available are 2 4 GHz and 5 GHz Not all computers or networks support the 5 GHz band Operation Mode Wi Fi security Mode Client...

Page 15: ...S It is automatically populated PSK Type Used to set the Pre Shared Key to join WPA WPA2 PSK enabled access points This field is not available for edit Default is 1 Enable Wi Fi Module Enable Disable...

Page 16: ...is infrastructure Feature Bitmap Configures different sub features in the SimScope Wi Fi module Not available for edit Mode 5 Pin USB Default value of 0 Configures the fifth pin on the USB connector...

Page 17: ...ured in the user configuration file of the Radius Server for the User Identity Visible only for Enterprise security Certificate Task Selects the type of certificate to load After selecting a task a fi...

Page 18: ...nection Parameters Name Function Registration Table Table that contains the friendly name and serial number of all wireless devices recognized by the PC application Name Column within the registration...

Page 19: ...e versatile Standardized patient interaction and assessment requires a standardized patient actor or manikin location patches SimScope and a PC with the SimScope software 1 Run the PC Application and...

Page 20: ...assigned in step 2 will begin playing Figure 3 Patch Placement for Standardized Patient Manikin Anterior Side 1 Aortic 2 Pulmonic 3 Tricuspid 4 Mitral Anterior Side 5 Lung Right Lower 6 Lung Right Up...

Page 21: ...n Do not bleach Do not machine dry Do not wring Remove the pulse pump system before laundering the Bionic Hybrid Simulator model Machine wash cool with gentle cycle Line dry only SimScope and Bionic H...

Page 22: ...ranty Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you 4 This warranty is limited to repair of the product or replacement thereo...

Page 23: ...22 3 Damage resulting from use of non Cardionics approved accessories...

Page 24: ...Revision C 014 3410...

Reviews: