15
Electrical connection (fig. 1)
Before connecting the device to the mains make sure that:
- the voltage and frequency rated on the data plate conform to those of the mains supply;
- an all pole circuit breaker which leaves at least
3 mm
between the contacts has been installed between
the device and the mains;
- the high voltage
230V
wires pass through the holes marked "
A
" and are routed separately from the low
voltage wires which pass through the holes marked "
B
";
- the wires are fastened down using a cable clamp.
Caution
: only low voltage circuits may be wired to the external circuit binding posts 1…6.
1
Outer conductor for radio receiver antenna
2
Inner conductor for radio receiver antenna with a 17 cm piece of rigid wire (if an external antenna is
fitted use a coaxial type cable
RG58
with an impedance of
50Ω
)
3
Anemometer input
4
Common for all inputs
5
Closing button input (N.O.)
6
Opening button input (N.O.)
7
Motor output (closing)
8
Motor output (opening)
9
Motor output (neutral)
10-11 Power supply
230 Vac 50-60 Hz
12 Power supply earth connection
13 Motor output earth connection
2
3
4
5
6
DC0565
CS1488
1
F3.15A
ANEM
8
9
10 11
7
13
12
TA
M
CH.
COM
A
P.
c
230V~
4
3
2
1
ON
D1
P1
TC
L
N
B1
RF MODULE
CODES
M1
J1 J2 J3 J4
Pos.1 Pos.2
J1
J2
J3
J4
J5
B
B
A
COLLEGAMENTO RADIO RENO
Radio Reno S504
01-06-2016
DC0565
Description:
Product Code :
Date :
Drawing number :
P.J.Heath
CARDIN ELETTRONICA S.p.A
- 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
Draft :
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
L1
L2
1
Summary of Contents for RPQ S504 Series
Page 55: ...55 Notes...