background image

USER MANUAL 

Revision 1.0

X11SDV-16C/-12C/-8C-TP8F

Summary of Contents for MBD-X11SDV-4C-TP8F-B

Page 1: ...USER MANUAL Revision 1 0 X11SDV 16C 12C 8C TP8F ...

Page 2: ...n a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful interference with radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case you will be required to correct the interference at your...

Page 3: ...d an NVMe connection Please note that this motherboard is intended to be installed and serviced by professional technicians only For processor memory updates please refer to our website at http www supermicro com products Conventions Used in the Manual Special attention should be given to the following symbols for proper installation and to prevent damage done to the components or injury to yourse...

Page 4: ... V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermicro nl Customer Support Website www supermicro nl Asia Pacific Address Super Micro Computer Inc 3F No 150 Jian 1st Rd Zhonghe Dist New Taipei City 235 Taiwan R O C Tel 886 2 8226 3990 Fax 886 2 8226 3...

Page 5: ... Environmental Temperature Control 19 System Resource Alert 19 1 5 ACPI Features 19 1 6 Power Supply 20 1 7 Serial Port 20 Chapter 2 Installation 2 1 Static Sensitive Devices 21 Precautions 21 Unpacking 21 2 2 Motherboard Installation 22 Tools Needed 22 Location of Mounting Holes 22 Installing the Motherboard 23 2 3 Memory Support and Installation 24 Memory Support 24 DIMM Module Population Config...

Page 6: ...ystem s Setup Configuration 58 When the System Becomes Unstable 58 3 2 Technical Support Procedures 60 3 3 Frequently Asked Questions 61 3 4 Battery Removal and Installation 62 Battery Removal 62 Proper Battery Disposal 62 Battery Installation 62 3 5 Returning Merchandise for Service 63 Chapter 4 BIOS 4 1 Introduction 64 Starting the Setup Utility 64 4 2 Main Setup 65 4 3 Advanced 67 4 4 Event Log...

Page 7: ...Installation B 1 Installing Software Programs 112 Appendix C Standardized Warning Statements Battery Handling 114 Product Disposal 116 Appendix D UEFI BIOS Recovery Appendix E Dual Boot Block BIOS Boot Block 122 BIOS Boot Block Corruption Occurrence 122 ...

Page 8: ...ith the motherboard are listed below If anything listed is damaged or missing please contact your retailer 1 1 Checklist Important Links For your system to work properly please follow the links below to download all necessary drivers utilities and the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities ftp ftp supermicro co...

Page 9: ...9 Chapter 1 Introduction Figure 1 1 X11SDV 16C TP8F Motherboard Image ...

Page 10: ...PUSB1 LEDM1 LEDT4 A C LEDT2 A C JMP1 JLANLED1 CPU SLOT6 PCI E 3 0 X16 JL1 JPW1 JPI2C1 JTPM1 JBT1 JPG1 JNS1 JTGLED2 JTGLED1 JIPMB1 COM1 JSD1 JF1 16 JD1 FANB FANA FAN4 FAN3 FAN1 FAN2 JMP1_SRW1 JMP1_SRW2 LEDPWR I SATA4 7 I SATA0 3 M 2 H PCI E 3 0 X2 S SATA4 CPU UID VGA DIMMB1 DIMME1 USB 0 1 USB 2 3 DIMMD1 DIMMA1 PCI E 3 0 X1 CPU SLOT6 PCI E 3 0 X16 CPU SLOT7 PCI E 3 0 X8 2 3 DISABLE 1 2 ENABLE JPB1 d...

Page 11: ...DOM PWR ON OH FF X RST NIC1 NIC2 JF1 PWR LED LED HDD 2 3 DISABLE 1 2 ENABLE JPL1 LAN1 2 3 4 LAN 1 2 LAN 7 8 LAN 5 6 LAN 3 4 IPMI_LAN USB 4 5 3 0 S SGPIO1 JGP1 JSTBY1 JNVI2C1 Notes See Chapter 2 for detailed information on jumpers I O ports and JF1 front panel connec tions Jumpers LED indicators not indicated are used for testing only indicates the location of Pin 1 When JLED1 Onboard Power LED ind...

Page 12: ... 3 00 GHz 3 00 GHz 3 00 GHz SoC Max TDP 80 W 85 W 100 W Number of Memory Channels 4 4 4 Maximum Memory Speed 2133 MHz 2133 MHz 2400 MHz Intel Turbo Boost Technology 2 00 2 00 2 00 Embedded Options Available Yes Yes Yes Integrated Intel QuickAssist Technology Yes Yes No Intel Virtualization Technology VT x Yes Yes Yes Intel Virtualization Technology for Directed I O VT d Yes Yes Yes Intel TSX NI Ye...

Page 13: ... Fail or Fan Fail LEDM1 BMC Heartbeat Blinking Green BMC Normal Connector Description BT1 Onboard Battery COM1 COM Header FAN1 FAN4 FANA FANB System CPU Fan Headers IPMI_LAN Dedicated IPMI LAN Port I SATA0 3 I SATA4 7 Eight Intel PCH SATA 3 0 Ports or Two NVMe U 2 Ports See jumper JNS1 setting JD1 PWR LED Buzzer Header Pins 1 4 PWR LED Pins 5 7 Buzzer JF1 Front Control Panel Header JGP1 General Pu...

Page 14: ...port JSMB1 System Management Bus Header JSTBY1 5V Standby Power Header JTGLED1 LAN7 LAN8 Activity LED Header JTGLED2 LAN5 LAN6 Activity LED Header JTPM1 Trusted Platform Module TPM Port 80 Connector LAN1 LAN4 1GbE RJ45 LAN Ports LAN5 LAN6 10GbE RJ45 LAN Ports LAN7 LAN8 10G SFP LAN Ports S SATA0 S SATA3 SATA 3 0 Ports S SGPIO1 Serial General Purpose I O Header for S SATA0 3 SLOT6 CPU PCI E 3 0 x16 ...

Page 15: ... PCI E 3 0 x2 slot Network Intel SoC integrated 10G Controller Baseboard Management Controller BMC ASpeed AST2500 Graphics Graphics controller via ASpeed AST2500 I O Devices Serial COM Header One 1 front accessible serial header COM1 SATA 3 0 Twelve 12 SATA 3 0 ports two additional via the M 2 connector RAID PCH RAID 0 1 5 and 10 Peripheral Devices Four 4 front accessible USB 2 0 headers USB0 1 US...

Page 16: ...stem Management PECI Platform Environment Control Interface 3 1 support Intel Node Manager IPMI 2 0 with KVM support SuperDoctor 5 Watch Dog NMI Chassis Intrusion header and detection Power supply monitoring LED Indicators CPU system overheat LED Power suspend state indicator LED Fan failed LED UID Remote UID HDD activity LED LAN activity LED Other RoHS Dimensions Flex ATX form factor 9 x 7 25 228...

Page 17: ...le I O 16 JPCIE2 SLOT6 PCIE 3 0 x16 PCIE 3 0 x16 JPCIE1 SLOT7 PCIE 3 0 x8 PCIE 3 0 x8 Flexible I O 18 25 Flexible I O 12 15 Flexible I O 10 DDR 3 BMC AST2500 PHY RTL8211F VGA CONN IPMI LAN SPI FLASH PCIE 3 0 x1 Flexible I O 11 VGA USB3 0 10G LAN SFP 3rd LAN SFP PCIE 3 0 x4 JLAN1 I350 AM4 JLAN2 M 2 M key CONN PCIE 3 0 x4 SATA3 0 5 Flexible I O 8 9 MINI SAS HD U 2 PCIE 3 0 x8 SATA GEN3 x8 SATA3 0 0 ...

Page 18: ...el Rapid Storage Technology Intel Virtualization Technology for Directed I O Intel VT d 1 3 Special Features This section describes the health monitoring features of the X11SDV 16C 12C 8C TP8F motherboard The motherboard has an onboard System Hardware Monitor chip that supports system health monitoring Recovery from AC Power Loss The Basic I O System BIOS provides a setting that determines how the...

Page 19: ...e Alert This feature is available when used with SuperDoctor 5 in the Windows OS or in the Linux environment SuperDoctor is used to notify the user of certain system events For example you can configure SuperDoctor to provide you with warnings when the system temperature CPU temperatures voltages and fan speeds go beyond a predefined range 1 5 ACPI Features ACPI stands for Advanced Configuration a...

Page 20: ...e It is recommended that you also install a power surge protector to help avoid problems caused by power surges Note 1 The X11SDV 16C 12C 8C TP8F motherboard alternatively supports an 8 pin 12V DC input power supply for embedded applications The 12V DC input is limited to a 36A design It provides up to 432W power input to the motherboard Keep onboard power use within the power limits specified abo...

Page 21: ...ges only do not touch its components peripheral chips memory modules or gold contacts When handling chips or modules avoid touching their pins Put the motherboard and peripherals back into their antistatic bags when not in use For grounding purposes make sure your computer chassis provides excellent conductivity between the power supply the case the mounting fasteners and the motherboard Use only ...

Page 22: ...C2 JF1 PWR LED LED HDD 2 3 DISABLE 1 2 ENABLE JPL1 LAN1 2 3 4 LAN 1 2 LAN 7 8 LAN 5 6 LAN 3 4 IPMI_LAN USB 4 5 3 0 S SGPIO1 JGP1 JSTBY1 JNVI2C1 2 2 Motherboard Installation All motherboards have standard mounting holes to fit different types of chassis Make sure that the locations of all the mounting holes for both the motherboard and the chassis match Although a chassis may have both plastic and ...

Page 23: ...as needed 4 Install the motherboard into the chassis carefully to avoid damaging other motherboard components 5 Using the Phillips screwdriver insert a Phillips head 6 screw into a mounting hole on the motherboard and its matching mounting hole on the chassis 6 Repeat Step 5 to insert 6 screws into all mounting holes 7 Make sure that the motherboard is securely placed in the chassis Note Images di...

Page 24: ...Hz in four memory slots Populating these DIMM slots with memory modules of the same type and size will result in interleaved memory which will improve memory performance DIMM Module Population Configuration For optimal memory performance follow the table below when populating memory Memory Population Balanced DIMMA1 DIMMB1 DIMMD1 DIMME1 Total System Memory 4GB 4GB 8GB 4GB 4GB 4GB 4GB 16GB 8GB 8GB ...

Page 25: ...U SLOT6 PCI E 3 0 X16 CPU SLOT7 PCI E 3 0 X8 2 3 DISABLE 1 2 ENABLE JPB1 debug only PCI E 3 0 X4 S SATA5 JMD1 M 2 HC 1 3 PWR LED 4 7 SPEAKER SUPER DOM PWR ON OH FF X RST NIC1 NIC2 JF1 PWR LED LED HDD 2 3 DISABLE 1 2 ENABLE JPL1 LAN1 2 3 4 LAN 1 2 LAN 7 8 LAN 5 6 LAN 3 4 IPMI_LAN USB 4 5 3 0 S SGPIO1 JGP1 JSTBY1 JNVI2C1 DIMMB1 DIMMA1 DIMM Module Population Sequence When installing memory modules th...

Page 26: ...C1 NIC2 JF1 PWR LED LED HDD 2 3 DISABLE 1 2 ENABLE JPL1 LAN1 2 3 4 LAN 1 2 LAN 7 8 LAN 5 6 LAN 3 4 IPMI_LAN USB 4 5 3 0 S SGPIO1 JGP1 JSTBY1 JNVI2C1 DIMM Installation 1 Insert the desired number of DIMMs into the memory slots starting with DIMMB1 DIMMA1 DIMME1 DIMMD1 For best performance please use the memory modules of the same type and speed in the same bank 2 Push the release tabs outwards on b...

Page 27: ...3 0 X16 JL1 JPW1 JPI2C1 JTPM1 JBT1 JPG1 JNS1 JTGLED2 JTGLED1 JIPMB1 COM1 JSD1 JF1 16 JD1 FANB FANA FAN4 FAN3 FAN1 FAN2 JMP1_SRW1 JMP1_SRW2 LEDPWR I SATA4 7 I SATA0 3 M 2 H PCI E 3 0 X2 S SATA4 CPU UID VGA DIMMB1 DIMME1 USB 0 1 USB 2 3 DIMMD1 DIMMA1 PCI E 3 0 X1 CPU SLOT6 PCI E 3 0 X16 CPU SLOT7 PCI E 3 0 X8 2 3 DISABLE 1 2 ENABLE JPB1 debug only PCI E 3 0 X4 S SATA5 JMD1 M 2 HC 1 3 PWR LED 4 7 SPE...

Page 28: ...SATA4 7 I SATA0 3 M 2 H PCI E 3 0 X2 S SATA4 CPU UID VGA DIMMB1 DIMME1 USB 0 1 USB 2 3 DIMMD1 DIMMA1 PCI E 3 0 X1 CPU SLOT6 PCI E 3 0 X16 CPU SLOT7 PCI E 3 0 X8 2 3 DISABLE 1 2 ENABLE JPB1 debug only PCI E 3 0 X4 S SATA5 JMD1 M 2 HC 1 3 PWR LED 4 7 SPEAKER SUPER DOM PWR ON OH FF X RST NIC1 NIC2 JF1 PWR LED LED HDD 2 3 DISABLE 1 2 ENABLE JPL1 LAN1 2 3 4 LAN 1 2 LAN 7 8 LAN 5 6 LAN 3 4 IPMI_LAN USB ...

Page 29: ... JSIM1 G2 G3 G4 G1 S3 S5 S6 S1 S2 S4 S SATA0 S SATA1 S SATA3 S SATA2 LEDT1 C A LEDT3 A C LED3 A C LED1 A C LED2 A C JMD1_SRW1 JMD2_SRW1 PRESS FIT PRESS FIT JPH1 JMD2 2 JPV1 BT1 SFP1 PRESS FIT JSMB1 1 JI2C1 JPL1 JI2C2 JPME2 1 JWD1 JPUSB1 LEDM1 LEDT4 A C LEDT2 A C JMP1 JLANLED1 CPU SLOT6 PCI E 3 0 X16 JL1 JPW1 JPI2C1 JTPM1 JBT1 JPG1 JNS1 JTGLED2 JTGLED1 JIPMB1 COM1 JSD1 JF1 16 JD1 FANB FANA FAN4 FAN...

Page 30: ...ns Color Status Blue On Unit Identified BAR CODE MADE IN USA X11SDV 8C TP8F REV 1 02 2 1 JSIM1 G2 G3 G4 G1 S3 S5 S6 S1 S2 S4 S SATA0 S SATA1 S SATA3 S SATA2 LEDT1 C A LEDT3 A C LED3 A C LED1 A C LED2 A C JMD1_SRW1 JMD2_SRW1 PRESS FIT PRESS FIT JPH1 JMD2 2 JPV1 BT1 SFP1 PRESS FIT JSMB1 1 JI2C1 JPL1 JI2C2 JPME2 1 JWD1 JPUSB1 LEDM1 LEDT4 A C LEDT2 A C JMP1 JLANLED1 CPU SLOT6 PCI E 3 0 X16 JL1 JPW1 JP...

Page 31: ...3 0 X16 CPU SLOT7 PCI E 3 0 X8 2 3 DISABLE 1 2 ENABLE JPB1 debug only PCI E 3 0 X4 S SATA5 JMD1 M 2 HC 1 3 PWR LED 4 7 SPEAKER SUPER DOM PWR ON OH FF X RST NIC1 NIC2 JF1 PWR LED LED HDD 2 3 DISABLE 1 2 ENABLE JPL1 LAN1 2 3 4 LAN 1 2 LAN 7 8 LAN 5 6 LAN 3 4 IPMI_LAN USB 4 5 3 0 S SGPIO1 JGP1 JSTBY1 JNVI2C1 Figure 2 2 JF1 Header Pins 2 5 Front Control Panel JF1 contains header pins for various butto...

Page 32: ...press the button for 4 seconds or longer Refer to the table below for pin definitions Power Button Pin Definitions JF1 Pin Definition 1 Signal 2 Ground Reset Button The Reset Button connection is located on pins 3 and 4 of JF1 Attach it to a hardware reset switch on the computer case Refer the table below for pin definitions Reset Button Pin Definitions JF1 Pin Definition 3 Reset 4 Ground Power Bu...

Page 33: ... Fan Fail Indicator Status State Definition Off Normal On Overheat Flashing Fan Fail OH Fan Fail LED Pin Definitions JF1 Pin Definition 7 Blue LED 8 OH Fan Fail LED 1 2 1 OH Fan Fail LED 2 NIC2 Activity LED 3 NIC1 Activity LED NIC1 NIC2 Activity LED The NIC Network Interface Controller LED connection for LAN port 1 is located on pins 11 and 12 of JF1 and the LED connection for LAN port 2 is on pin...

Page 34: ...initions HDD LED Pin Definitions JF1 Pin Definition 13 3 3V Stdby UID_SW 14 HDD Active 1 2 1 HDD LED 2 PWR LED Power LED The Power LED connection is located on pins 15 and 16 of JF1 See the table below for pin definitions Power LED Pin Definitions JF1 Pin Definition 15 3 3V 16 PWR LED Power Button OH Fan Fail LED NIC1 Activity LED Reset Button HDD LED PWR LED Reset PWR 3 3V Stby 3 3V Stby Ground 1...

Page 35: ...r to the table below for pin definitions PWR Fail LED Pin Definitions JF1 Pin Definition 5 3 3V 6 Power Fail Power Button OH Fan Fail LED NIC1 Activity LED Reset Button HDD LED PWR LED Reset PWR 3 3V Stby 3 3V Stby Ground 15 3 3V Stby 16 1 2 Ground NIC2 Activity LED PWR Fail LED UID 3 3V 3 3V 1 1 PWR Fail LED ...

Page 36: ...D3 A C LED1 A C LED2 A C JMD1_SRW1 JMD2_SRW1 PRESS FIT PRESS FIT JPH1 JMD2 2 JPV1 BT1 SFP1 PRESS FIT JSMB1 1 JI2C1 JPL1 JI2C2 JPME2 1 JWD1 JPUSB1 LEDM1 LEDT4 A C LEDT2 A C JMP1 JLANLED1 CPU SLOT6 PCI E 3 0 X16 JL1 JPW1 JPI2C1 JTPM1 JBT1 JPG1 JNS1 JTGLED2 JTGLED1 JIPMB1 COM1 JSD1 JF1 16 JD1 FANB FANA FAN4 FAN3 FAN1 FAN2 JMP1_SRW1 JMP1_SRW2 LEDPWR I SATA4 7 I SATA0 3 M 2 H PCI E 3 0 X2 S SATA4 CPU U...

Page 37: ...JLANLED1 CPU SLOT6 PCI E 3 0 X16 JL1 JPW1 JPI2C1 JTPM1 JBT1 JPG1 JNS1 JTGLED2 JTGLED1 JIPMB1 COM1 JSD1 JF1 16 JD1 FANB FANA FAN4 FAN3 FAN1 FAN2 JMP1_SRW1 JMP1_SRW2 LEDPWR I SATA4 7 I SATA0 3 M 2 H PCI E 3 0 X2 S SATA4 CPU UID VGA DIMMB1 DIMME1 USB 0 1 USB 2 3 DIMMD1 DIMMA1 PCI E 3 0 X1 CPU SLOT6 PCI E 3 0 X16 CPU SLOT7 PCI E 3 0 X8 2 3 DISABLE 1 2 ENABLE JPB1 debug only PCI E 3 0 X4 S SATA5 JMD1 M...

Page 38: ...y PCI E 3 0 X4 S SATA5 JMD1 M 2 HC 1 3 PWR LED 4 7 SPEAKER SUPER DOM PWR ON OH FF X RST NIC1 NIC2 JF1 PWR LED LED HDD 2 3 DISABLE 1 2 ENABLE JPL1 LAN1 2 3 4 LAN 1 2 LAN 7 8 LAN 5 6 LAN 3 4 IPMI_LAN USB 4 5 3 0 S SGPIO1 JGP1 JSTBY1 JNVI2C1 Headers 3 5 4 Fan Headers The X11SDV 16C 12C 8C TP8F has six 4 pin fan headers FAN1 FAN4 FANA FANB These headers are backwards compatible with the traditional 3 ...

Page 39: ... DIMMA1 PCI E 3 0 X1 CPU SLOT6 PCI E 3 0 X16 CPU SLOT7 PCI E 3 0 X8 2 3 DISABLE 1 2 ENABLE JPB1 debug only PCI E 3 0 X4 S SATA5 JMD1 M 2 HC 1 3 PWR LED 4 7 SPEAKER SUPER DOM PWR ON OH FF X RST NIC1 NIC2 JF1 PWR LED LED HDD 2 3 DISABLE 1 2 ENABLE JPL1 LAN1 2 3 4 LAN 1 2 LAN 7 8 LAN 5 6 LAN 3 4 IPMI_LAN USB 4 5 3 0 S SGPIO1 JGP1 JSTBY1 JNVI2C1 Chassis Intrusion A Chassis Intrusion header is located ...

Page 40: ... JNS1 JTGLED2 JTGLED1 JIPMB1 COM1 JSD1 JF1 16 JD1 FANB FANA FAN4 FAN3 FAN1 FAN2 JMP1_SRW1 JMP1_SRW2 LEDPWR I SATA4 7 I SATA0 3 M 2 H PCI E 3 0 X2 S SATA4 CPU UID VGA DIMMB1 DIMME1 USB 0 1 USB 2 3 DIMMD1 DIMMA1 PCI E 3 0 X1 CPU SLOT6 PCI E 3 0 X16 CPU SLOT7 PCI E 3 0 X8 2 3 DISABLE 1 2 ENABLE JPB1 debug only PCI E 3 0 X4 S SATA5 JMD1 M 2 HC 1 3 PWR LED 4 7 SPEAKER SUPER DOM PWR ON OH FF X RST NIC1 ...

Page 41: ... S SATA1 S SATA3 S SATA2 LEDT1 C A LEDT3 A C LED3 A C LED1 A C LED2 A C JMD1_SRW1 JMD2_SRW1 PRESS FIT PRESS FIT JPH1 JMD2 2 JPV1 BT1 SFP1 PRESS FIT JSMB1 1 JI2C1 JPL1 JI2C2 JPME2 1 JWD1 JPUSB1 LEDM1 LEDT4 A C LEDT2 A C JMP1 JLANLED1 CPU SLOT6 PCI E 3 0 X16 JL1 JPW1 JPI2C1 JTPM1 JBT1 JPG1 JNS1 JTGLED2 JTGLED1 JIPMB1 COM1 JSD1 JF1 16 JD1 FANB FANA FAN4 FAN3 FAN1 FAN2 JMP1_SRW1 JMP1_SRW2 LEDPWR I SAT...

Page 42: ... PCI E 3 0 X8 2 3 DISABLE 1 2 ENABLE JPB1 debug only PCI E 3 0 X4 S SATA5 JMD1 M 2 HC 1 3 PWR LED 4 7 SPEAKER SUPER DOM PWR ON OH FF X RST NIC1 NIC2 JF1 PWR LED LED HDD 2 3 DISABLE 1 2 ENABLE JPL1 LAN1 2 3 4 LAN 1 2 LAN 7 8 LAN 5 6 LAN 3 4 IPMI_LAN USB 4 5 3 0 S SGPIO1 JGP1 JSTBY1 JNVI2C1 1 2 1 SMBus Header 2 Power SMB I2 C Power SMB I2 C Header The Power System Management Bus I2 C connector JPI2 ...

Page 43: ... FAN1 FAN2 JMP1_SRW1 JMP1_SRW2 LEDPWR I SATA4 7 I SATA0 3 M 2 H PCI E 3 0 X2 S SATA4 CPU UID VGA DIMMB1 DIMME1 USB 0 1 USB 2 3 DIMMD1 DIMMA1 PCI E 3 0 X1 CPU SLOT6 PCI E 3 0 X16 CPU SLOT7 PCI E 3 0 X8 2 3 DISABLE 1 2 ENABLE JPB1 debug only PCI E 3 0 X4 S SATA5 JMD1 M 2 HC 1 3 PWR LED 4 7 SPEAKER SUPER DOM PWR ON OH FF X RST NIC1 NIC2 JF1 PWR LED LED HDD 2 3 DISABLE 1 2 ENABLE JPL1 LAN1 2 3 4 LAN 1...

Page 44: ... SATA0 3 M 2 H PCI E 3 0 X2 S SATA4 CPU UID VGA DIMMB1 DIMME1 USB 0 1 USB 2 3 DIMMD1 DIMMA1 PCI E 3 0 X1 CPU SLOT6 PCI E 3 0 X16 CPU SLOT7 PCI E 3 0 X8 2 3 DISABLE 1 2 ENABLE JPB1 debug only PCI E 3 0 X4 S SATA5 JMD1 M 2 HC 1 3 PWR LED 4 7 SPEAKER SUPER DOM PWR ON OH FF X RST NIC1 NIC2 JF1 PWR LED LED HDD 2 3 DISABLE 1 2 ENABLE JPL1 LAN1 2 3 4 LAN 1 2 LAN 7 8 LAN 5 6 LAN 3 4 IPMI_LAN USB 4 5 3 0 S...

Page 45: ... CPU SLOT7 PCI E 3 0 X8 2 3 DISABLE 1 2 ENABLE JPB1 debug only PCI E 3 0 X4 S SATA5 JMD1 M 2 HC 1 3 PWR LED 4 7 SPEAKER SUPER DOM PWR ON OH FF X RST NIC1 NIC2 JF1 PWR LED LED HDD 2 3 DISABLE 1 2 ENABLE JPL1 LAN1 2 3 4 LAN 1 2 LAN 7 8 LAN 5 6 LAN 3 4 IPMI_LAN USB 4 5 3 0 S SGPIO1 JGP1 JSTBY1 JNVI2C1 1 2 1 JLANLED1 Header 2 JTGLED1 Header 3 JTGLED2 Header LAN Activity LED Headers JTGLED1 is the acti...

Page 46: ... SLOT6 PCI E 3 0 X16 JL1 JPW1 JPI2C1 JTPM1 JBT1 JPG1 JNS1 JTGLED2 JTGLED1 JIPMB1 COM1 JSD1 JF1 16 JD1 FANB FANA FAN4 FAN3 FAN1 FAN2 JMP1_SRW1 JMP1_SRW2 LEDPWR I SATA4 7 I SATA0 3 M 2 H PCI E 3 0 X2 S SATA4 CPU UID VGA DIMMB1 DIMME1 USB 0 1 USB 2 3 DIMMD1 DIMMA1 PCI E 3 0 X1 CPU SLOT6 PCI E 3 0 X16 CPU SLOT7 PCI E 3 0 X8 2 3 DISABLE 1 2 ENABLE JPB1 debug only PCI E 3 0 X4 S SATA5 JMD1 M 2 HC 1 3 PW...

Page 47: ...SATA0 3 M 2 H PCI E 3 0 X2 S SATA4 CPU UID VGA DIMMB1 DIMME1 USB 0 1 USB 2 3 DIMMD1 DIMMA1 PCI E 3 0 X1 CPU SLOT6 PCI E 3 0 X16 CPU SLOT7 PCI E 3 0 X8 2 3 DISABLE 1 2 ENABLE JPB1 debug only PCI E 3 0 X4 S SATA5 JMD1 M 2 HC 1 3 PWR LED 4 7 SPEAKER SUPER DOM PWR ON OH FF X RST NIC1 NIC2 JF1 PWR LED LED HDD 2 3 DISABLE 1 2 ENABLE JPL1 LAN1 2 3 4 LAN 1 2 LAN 7 8 LAN 5 6 LAN 3 4 IPMI_LAN USB 4 5 3 0 S ...

Page 48: ...horts between two pins to change the function of the connector Pin 1 is identified with a square solder pad on the printed circuit board See the diagram below for an example of jumping pins 1 and 2 Refer to the motherboard layout page for jumper locations Note On two pin jumpers Closed means the jumper is on and Open means the jumper is off the pins Connector Pins Jumper Setting 3 2 1 3 2 1 ...

Page 49: ...LANLED1 CPU SLOT6 PCI E 3 0 X16 JL1 JPW1 JPI2C1 JTPM1 JBT1 JPG1 JNS1 JTGLED2 JTGLED1 JIPMB1 COM1 JSD1 JF1 16 JD1 FANB FANA FAN4 FAN3 FAN1 FAN2 JMP1_SRW1 JMP1_SRW2 LEDPWR I SATA4 7 I SATA0 3 M 2 H PCI E 3 0 X2 S SATA4 CPU UID VGA DIMMB1 DIMME1 USB 0 1 USB 2 3 DIMMD1 DIMMA1 PCI E 3 0 X1 CPU SLOT6 PCI E 3 0 X16 CPU SLOT7 PCI E 3 0 X8 2 3 DISABLE 1 2 ENABLE JPB1 debug only PCI E 3 0 X4 S SATA5 JMD1 M ...

Page 50: ... 1 JSIM1 G2 G3 G4 G1 S3 S5 S6 S1 S2 S4 S SATA0 S SATA1 S SATA3 S SATA2 LEDT1 C A LEDT3 A C LED3 A C LED1 A C LED2 A C JMD1_SRW1 JMD2_SRW1 PRESS FIT PRESS FIT JPH1 JMD2 2 JPV1 BT1 SFP1 PRESS FIT JSMB1 1 JI2C1 JPL1 JI2C2 JPME2 1 JWD1 JPUSB1 LEDM1 LEDT4 A C LEDT2 A C JMP1 JLANLED1 CPU SLOT6 PCI E 3 0 X16 JL1 JPW1 JPI2C1 JTPM1 JBT1 JPG1 JNS1 JTGLED2 JTGLED1 JIPMB1 COM1 JSD1 JF1 16 JD1 FANB FANA FAN4 F...

Page 51: ... PWR LED LED HDD 2 3 DISABLE 1 2 ENABLE JPL1 LAN1 2 3 4 LAN 1 2 LAN 7 8 LAN 5 6 LAN 3 4 IPMI_LAN USB 4 5 3 0 S SGPIO1 JGP1 JSTBY1 JNVI2C1 1 1 Watch Dog Timer 2 SMBus to PCI E Slots 2 SMBus to PCI E Slots Use jumpers JI2C1 and JI2C2 to enable PCI E SMB System Management Bus support to improve system management for the onboard PCI E slot SMBus to PCI E Slots Jumper Settings Jumper Setting Definition...

Page 52: ...LE JPB1 debug only PCI E 3 0 X4 S SATA5 JMD1 M 2 HC 1 3 PWR LED 4 7 SPEAKER SUPER DOM PWR ON OH FF X RST NIC1 NIC2 JF1 PWR LED LED HDD 2 3 DISABLE 1 2 ENABLE JPL1 LAN1 2 3 4 LAN 1 2 LAN 7 8 LAN 5 6 LAN 3 4 IPMI_LAN USB 4 5 3 0 S SGPIO1 JGP1 JSTBY1 JNVI2C1 1 1 Mini SAS Mode Select 2 USB Wake Up 2 USB Wake Up Use the JPUSB1 jumper to enable system wake up via a USB device This jumper allows you to w...

Page 53: ...LED3 A C LED1 A C LED2 A C JMD1_SRW1 JMD2_SRW1 PRESS FIT PRESS FIT JPH1 JMD2 2 JPV1 BT1 SFP1 PRESS FIT JSMB1 1 JI2C1 JPL1 JI2C2 JPME2 1 JWD1 JPUSB1 LEDM1 LEDT4 A C LEDT2 A C JMP1 JLANLED1 CPU SLOT6 PCI E 3 0 X16 JL1 JPW1 JPI2C1 JTPM1 JBT1 JPG1 JNS1 JTGLED2 JTGLED1 JIPMB1 COM1 JSD1 JF1 16 JD1 FANB FANA FAN4 FAN3 FAN1 FAN2 JMP1_SRW1 JMP1_SRW2 LEDPWR I SATA4 7 I SATA0 3 M 2 H PCI E 3 0 X2 S SATA4 CPU...

Page 54: ... 2 3 DISABLE 1 2 ENABLE JPB1 debug only PCI E 3 0 X4 S SATA5 JMD1 M 2 HC 1 3 PWR LED 4 7 SPEAKER SUPER DOM PWR ON OH FF X RST NIC1 NIC2 JF1 PWR LED LED HDD 2 3 DISABLE 1 2 ENABLE JPL1 LAN1 2 3 4 LAN 1 2 LAN 7 8 LAN 5 6 LAN 3 4 IPMI_LAN USB 4 5 3 0 S SGPIO1 JGP1 JSTBY1 JNVI2C1 1 1 Onboard PWR LED 2 BMC Heartbeat LED 2 BMC Heartbeat LED LEDM1 is the BMC heartbeat LED When the LED is blinking green B...

Page 55: ... JMP1_SRW1 JMP1_SRW2 LEDPWR I SATA4 7 I SATA0 3 M 2 H PCI E 3 0 X2 S SATA4 CPU UID VGA DIMMB1 DIMME1 USB 0 1 USB 2 3 DIMMD1 DIMMA1 PCI E 3 0 X1 CPU SLOT6 PCI E 3 0 X16 CPU SLOT7 PCI E 3 0 X8 2 3 DISABLE 1 2 ENABLE JPB1 debug only PCI E 3 0 X4 S SATA5 JMD1 M 2 HC 1 3 PWR LED 4 7 SPEAKER SUPER DOM PWR ON OH FF X RST NIC1 NIC2 JF1 PWR LED LED HDD 2 3 DISABLE 1 2 ENABLE JPL1 LAN1 2 3 4 LAN 1 2 LAN 7 8...

Page 56: ...luding those for the keyboard and mouse 3 Remove all add on cards 4 Install the CPU making sure it is fully seated and connect the front panel connectors to the motherboard No Power 1 Make sure that there are no short circuits between the motherboard and the chassis 2 Make sure that the ATX power connectors are properly connected 3 Check that the 115V 230V switch if available on the power supply i...

Page 57: ...stalled If the system boots check for bad DIMM modules or slots by following the Memory Errors Troubleshooting procedure in this chapter Memory Errors When a no memory beep code is issued by the system check the following 1 Make sure that the memory modules are compatible with the system and that the DIMMs are properly and fully installed Click on the Tested Memory List link on the motherboard pro...

Page 58: ...List link on the motherboard product page to see a list of supported memory 3 HDD support Make sure that all hard disk drives HDDs work properly Replace the bad HDDs with good ones 4 System cooling Check the system cooling to make sure that all heatsink fans and CPU system fans etc work properly Check the hardware monitoring settings in the IPMI to make sure that the CPU and system temperatures ar...

Page 59: ...f necessary remove a component in question from the chassis and test it in isolation to make sure that it works properly Replace a bad component with a good one 5 Check and change one component at a time instead of changing several items at the same time This will help isolate and identify the problem 6 To find out if a component is good swap this component with a new one to see if the system will...

Page 60: ...AQs on our website http www supermicro com FAQ index php before contacting Technical Support 2 BIOS upgrades can be downloaded from our website http www supermicro com ResourceApps BIOS_IPMI_Intel html 3 If you still cannot resolve the problem include the following information when contacting Supermicro for technical support Motherboard model and PCB revision number BIOS release date version This ...

Page 61: ...ormation on how to update your BIOS on our website Select your motherboard model and download the BIOS file to your computer Also check the current BIOS revision to make sure that it is newer than your BIOS before downloading You can choose from the zip file and the exe file If you choose the zip BIOS file please unzip the BIOS file onto a bootable USB device Run the batch file using the format FL...

Page 62: ... damage the battery in any way a damaged battery may release hazardous materials into the environment Do not discard a used battery in the garbage or a public landfill Please comply with the regulations set up by your local hazardous waste management agency to dispose of your used battery properly Battery Installation 1 To install an onboard battery follow steps 1 and 2 above and continue below 2 ...

Page 63: ...ently displayed on the outside of the shipping carton and mailed prepaid or hand carried Shipping and handling charges will be applied for all orders that must be mailed when service is complete For faster service RMA authorizations may be requested online http www supermicro com support rma This warranty only covers normal consumer use and does not cover damages incurred in shipping or from failu...

Page 64: ...sed such as F1 F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be configured The right frame displays the key legend Above the key legend is an area reserved for a text message When an option is selected in the left frame it is highlighted in white Often a...

Page 65: ...ht System Date or System Time using the arrow keys Enter new values using the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in MM DD YYYY format The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5 30 P M appears as 17 30 00 The date s default value is the BIOS build date after RTC reset Supermicro X11SDV 16C TP8...

Page 66: ...8F User s Manual 66 Memory Information Total Memory This feature displays the total size of memory available in the system Memory Speed This feature displays the default speed of the memory modules installed in the system ...

Page 67: ...play between POST messages or the OEM logo at bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the normal POST messages The options are Disabled and Enabled Option ROM Messages Use this feature to set the display mode for the Option ROM Select Keep Current to display the current AddOn ROM setting Select Force BIOS to use the Option ROM display s...

Page 68: ...n Select Enabled to enable the emulation of Port 61h bit 4 toggling in SMM System Management Mode The options are Disabled and Enabled Power Configuration Watch Dog Function If enabled the Watch Dog timer will allow the system to reboot when it is inactive for more than five minutes The options are Disabled and Enabled Power Button Function This feature controls how the system shuts down when the ...

Page 69: ... for Execute Disable Bit support which will allow the processor to designate areas in the system memory where an application code can execute and where it cannot thus preventing a worm or a virus from flooding illegal codes to overwhelm the processor or damaging the system during a virus attack The options are Disable and Enable Refer to Intel and Microsoft websites for more information Intel Virt...

Page 70: ...s are Disable and Enable DCU IP Prefetcher Available when supported by the CPU Select Enable for DCU Data Cache Unit IP Prefetcher support which will prefetch IP addresses to improve network connectivity and system performance The options are Enable and Disable LLC Prefetch If set to Enable the hardware prefetcher will prefetch streams of data and instructions from the main memory to the L3 cache ...

Page 71: ...ws the user to configure the following CPU power settings SpeedStep Pstates Intel SpeedStep Technology allows the system to automatically adjust processor volt age and core frequency to reduce power consumption and heat dissipation The options are Disable and Enable If this feature is set to Disabled the next two features are not available for configuration EIST PSD Funtion This feature allows the...

Page 72: ...ons are Disable and Enable This feature must be set to Disable to be able to configure the next two features CPU C6 Report Select Enable to allow the BIOS to report the CPU C6 State ACPI C3 to the operating system During the CPU C6 State the power to all cache is turned off The options are Disable Enable and Auto Enhanced Halt State C1E Select Enable to use Enhanced Halt State technology which wil...

Page 73: ...Feature Precedence to degrade Topol ogy The options are Topology Precedence and Feature Precedence Link L0p Enable Select Enable for the QPI to enter the L0p state for power saving The options are Dis able Enable and Auto Link L1 Enable Select Enable for the QPI to enter the L1 state for power saving The options are Dis able Enable and Auto IO Directory Cache IODC IO Directory Cache is an 8 entry ...

Page 74: ...n of Record to enforce POR restrictions on DDR4 frequency and volt age programming The options are POR and Disable Memory Frequency Use this feature to set the maximum memory frequency for onboard memory modules The options are Auto 2133 2400 and 2666 Data Scrambling for DDR4 Use this feature to enable or disable data scrambling for DDR4 memory The options are Auto Disable and Enable tCCD_L Relaxa...

Page 75: ... to indicate how many memory ranks to reserve in case of memory failure The options are One Rank and Two Rank Correctable Error Threshold Use this feature to specify the threshold value for correctable memory error logging which sets a limit on the maximum number of events that can be logged in the memory error log at a given time The default setting is 100 SDDC Single device data correction 1 SDD...

Page 76: ...d to enter a value from 0 24 The default setting is 24 IIO Configuration EV DFX Features When this feature is set to Enable the EV_DFX Lock Bits that are located on a proces sor will always remain clear during electric tuning The options are Disable and Enable CPU Configuration IOU0 II0 PCIe Br1 Use this feature configures the PCI E port Bifuraction setting for a PCI E port specified by the user T...

Page 77: ... GT s Gen 2 5GT s and Gen 3 GT s PCI E Port Link Status This feature shows the status of the device plugged into this slot PCI E Port Link Max This feature shows the status of the device plugged into this slot PCI E Port Link Speed This feature shows the status of the device plugged into this slot PCI E Port Max Payload Size Use this feature to select the maximum payload size for this port The opt...

Page 78: ...le and Disable If the feature above is set to Enable the five features below will be available for configuration Interrupt Remapping Use this feature to enable Interrupt Remapping support which detects and controls external interrupt requests The options are Enable and Disable PassThrough DMA Use this feature to allow devices such as network cards to access the system memory without using a proces...

Page 79: ... for PCIe root ports 1A 1D The options are Disable and Enable PCI E Completion Timeout Disable Use this feature to enable PCI E Completion Timeout support for electric tuning The options are Yes No and Per Port South Bridge Configuration The following South Bridge information will display USB Module Version USB Devices Legacy USB Support Select Enabled to support onboard legacy USB devices Select ...

Page 80: ...splays the following features SATA Controller This feature enables or disables the onboard SATA controller supported by the Intel PCH chip The options are Disable and Enable Configure SATA as Select AHCI to configure a SATA drive specified by the user as an AHCI drive Select RAID to configure a SATA drive specified by the user as a RAID drive The options are AHCI and RAID SATA HDD Unlock This feat...

Page 81: ...ting down the system The options are Disable and Enable Port 0 7 Spin Up Device On an edge detect from 0 to 1 set this feature to allow the PCH to initialize the device The options are Disable and Enable Port 0 7 SATA Device Type Use this feature to specify if the SATA port specified by the user should be connected to a Solid State drive or a Hard Disk Drive The options are Hard Disk Drive and Sol...

Page 82: ...and Enable sSATA RAID Option ROM UEFI Driver Select UEFI to load the EFI driver for system boot Select Legacy to load a legacy driver for system boot The options are Disable EFI and Legacy sSATA Port 0 Port 5 This feature displays the information detected on the installed sSATA drive on the particular sSATA port Model number of drive and capacity Software Preserve Support Port 0 Port 5 Hot Plug Se...

Page 83: ...lect the high memory size according to memory address mapping for the IO hub The options are 1G 4G 16G 64G 256G and 1024G Maximum Read Request Use this feature to select the Maximum Read Request size of the PCI Express device or select Auto to allow the System BIOS to determine the value The options are Auto 128 Bytes 256 Bytes 512 Bytes 1024 Bytes 2048 Bytes and 4096 Bytes MMCFG Base Use this fea...

Page 84: ...is feature to select which firmware type to be loaded for the add on card in this slot The options are Disabled Legacy and EFI PCI E 3 0 X1 OPROM Use this feature to select which firmware type to be loaded for the add on card in this slot The options are Disabled Legacy and EFI Onboard LAN Option ROM Type Use this feature to select which firmware type to be loaded for onboard LAN devices The optio...

Page 85: ...Ipv6 PXE Support Select Enabled to enable IPv6 PXE boot support The options are Disabled and Enabled Ipv6 HTTP Support Select Enabled to enable IPv6 HTTP boot support The options are Disabled and Enabled PXE Boot Wait Time Use this option to specify the wait time to press the ESC key to abort the PXE boot Press or on your keyboard to change the value The default setting is 0 Media Detect Count Use...

Page 86: ...s to display and only the Change Settings feature is available for configuration Device Settings This feature displays the base I O port address and the Interrupt Request address of a serial port specified by the user Change Settings This feature specifies the base I O port address and the Interrupt Request address of Serial Port 1 Select Auto for the BIOS to automatically assign the base I O and ...

Page 87: ... to detect data transmission errors Select Even if the parity bit is set to 0 and the number of 1 s in data bits is even Select Odd if the parity bit is set to 0 and the number of 1 s in data bits is odd Select None if you do not want to send a parity bit with your data bits in transmission Select Mark to add a mark as a parity bit to be sent along with the data bits Select Space to add a Space as...

Page 88: ... When set to BootLoader legacy console redirection is disabled before booting the OS When set to Always Enable legacy console redirection remains enabled when booting the OS The options are Always Enable and BootLoader SOL Console Redirection Select Enabled to use the SOL port for Console Redirection The options are Disabled and Enabled If the feature above is set to Enabled the following features...

Page 89: ...your data bits The options are None Even Odd Mark and Space Stop Bits A stop bit indicates the end of a serial data packet Select 1 Stop Bit for standard serial data communication Select 2 Stop Bits if slower devices are used The options are 1 and 2 Flow Control Use this feature to set the flow control for Console Redirection to prevent data loss caused by buffer overflow Send a Stop signal to sto...

Page 90: ...messages The options are COM1 and SOL Serial Port for Out of Band Management Windows Emergency Management Services EMS The submenu allows the user to configure Console Redirection settings to support Out of Band Serial Port management EMS Emergency Management Services Console Redirection Select Enabled to use a COM port selected by the user for EMS Console Redirection The options are Disabled and ...

Page 91: ... Send a Start signal to start sending data when the receiving buffer is empty The options are None Hardware RTS CTS and Software Xon Xoff Data Bits Parity Stop Bits ACPI Settings Use this feature to configure Advanced Configuration and Power Interface ACPI power management settings for your system WHEA Support Select Enabled to support the Windows Hardware Error Architecture WHEA platform and prov...

Page 92: ...urity device for system data integrity Your system will reboot to carry out a pending TPM operation The options are None and TPM Clear Note Your system will reboot to carry out a pending TPM operation Device Select Use this feature to select the TPM version TPM 1 2 will restrict support to TPM 1 2 devices TPM 2 0 will restrict support for TPM 2 0 devices Select Auto to enable support for both vers...

Page 93: ...res are available for configuration SHA256 PCR Bank Use this feature to disable or enable the SHA256 Platform Configuration Register PCR bank for the installed TPM device The options are Disabled and Enabled Pending operation Use this feature to schedule a TPM related operation to be performed by a security device for system data integrity Your system will reboot to carry out a pending TPM operati...

Page 94: ...tiality and integrity of data stored or created on the system Use this feature to enable or disable TXT Support The options are Disabled and Enabled iSCSI Configuration iSCSI Initiator Name This feature allows the user to enter the unique name of the iSCSI Initiator in IQN format Once the name of the iSCSI Initiator is entered into the system configure the proper settings for the following feature...

Page 95: ...nd Disabled Erasing Settings Erase Event Log Select Enabled to erase all error events in the SMBIOS System Management BIOS log before an event logging is initialized at bootup The options are No Yes Next reset and Yes Every reset When Log is Full Select Erase Immediately to immediately erase all errors in the SMBIOS event log when the event log is full Select Do Nothing for the system to do nothin...

Page 96: ...etween 1 to 255 The default setting is 1 METW Multiple Event Count Time Window This feature is used to determine how long in minutes should the multiple event counter wait before generating a new event log Enter a number between 0 to 99 The default setting is 60 Note Please reboot the system for the changes to take effect View SMBIOS Event Log This feature allows the user to view the event in the ...

Page 97: ...n your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Disabled and Enabled Erasing Settings Erase SEL Select Yes On next reset to erase all system event logs upon next system reboot Select Yes On every reset to erase all system event logs upon each system reboot Select No to keep all system event logs after ea...

Page 98: ...and Yes If the feature above is set to Yes the Configuration Address Source and VLAN features are available for configuration Configuration Address Source Use this feature to select the source of the IP address for this computer If Static is selected you will need to know the IP address of this computer and enter it to the system manually in the field If DHCP is selected the BIOS will search for a...

Page 99: ...Use this feature to enable IPV6 support The options are Enabled and Disabled Configuration Address Source Use this feature to select the source of the IP address for this computer If Static is selected you will need to know the IP address of this computer and enter it to the system manually in the field If DHCP is selected the BIOS will search for a DHCP Dynamic Host Configuration Protocol server ...

Page 100: ...rt for extended IPMI features The Disable option is for applications that require faster power on time wthout using Supermicro Update Manager SUM or extended IPMI features The BMC network configuration in the BIOS setup is also invalid when IPMI Function Support is disabled The general BMC function and motherboard health monitor such as fan control are still functioning even when this option is di...

Page 101: ...e password should be from 3 characters to 20 characters long Password Check Select Setup for the system to check for a password at Setup Select Always for the system to check for a password at bootup or upon entering the BIOS Setup utility The options are Setup and Always Secure Boot System Mode Vendor Keys Secure Boot Enable Select Enable for secure boot support to ensure system security at bootu...

Page 102: ...ures are available for configuration Restore Factory Keys Select Yes to restore all factory keys to the default settings The options are Yes and No Reset to Setup Mode Select Yes to delete all Secure Boot key databases and force the system to Setup Mode The options are Yes and No Export Secure Boot variables Use this feature to copy the NVRAM contents of the secure boot variables to a file Enroll ...

Page 103: ...w the details of the Key Exchange Key Export Select Yes to export a KEK from a file on an external media Update Select Yes to load a factory default KEK or No to load from a file on an external media Append Select Yes to add the KEK from the manufacturer s defaults list to the existing KEK Select No to load the KEK from a file The options are Yes and No Delete Select Ok to remove the KEK and then ...

Page 104: ...pend Select Yes to add the dbx from the manufacturer s defaults list to the existing dbx Select No to load the dbx from a file The options are Yes and No Delete Select Ok to remove the dbx and then the system will reset to Setup Audit Mode Authorized TimeStamps Details Select this feature to view the details of the dbt Export Select Yes to export a dbt from a file on an external media Update Selec...

Page 105: ... external media Update Select Yes to load a factory default dbr or No to load from a file on an external media Append Select Yes to add the dbr from the manufacturer s defaults list to the existing dbr Select No to load the dbr from a file The options are Yes and No Delete Select Ok to remove the dbr and then the system will reset to Setup Audit Mode ...

Page 106: ...o EFI Support Select Enabled to boot EFI OS support after Legacy boot order has failed The options are Disabled and Enabled Fixed BOOT ORDER Priorities This option prioritizes the order of bootable devices that the system to boot from Press Enter on each entry from top to bottom to select devices Boot Option 1 Boot Option 2 Boot Option 3 Boot Option 4 Boot Option 5 Boot Option 6 Boot Option 7 ...

Page 107: ...ture to select a boot device to delete from the boot priority list UEFI Application Boot Priorities Boot Option This feature sets the system boot order of detected devices The options are the list of detected boot device s and Disabled NETWORK Drive BBS Priorities Boot Option This feature sets the system boot order of detected devices The options are the list of detected boot device s and Disabled...

Page 108: ...ct Discard Changes and Exit from the Exit menu and press Enter Save Changes and Reset When you have completed the system configuration changes select this option to save all changes made and reset the system Save Changes When you have completed the system configuration changes select this option to save all changes made This will not reset reboot the system Discard Changes Select this option and p...

Page 109: ... from the Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Defaults from the Exit menu and press Enter Use this feature to retrieve user defined settings that were saved previously Boot Override Other boot options are listed in this section The system will boot to the selected boot opt...

Page 110: ...up If a fatal error occurs you should consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The table below lists some common errors and their corresponding beep codes encountered by users BIOS Beep POST Codes Beep Code Error Message Description 1 beep Refresh Circuits have been reset Ready to power up 5 short 1 lon...

Page 111: ...om support manuals AMI BIOS POST Codes User s Guide When BIOS performs the Power On Self Test it writes checkpoint codes to I O port 0080h If the computer cannot complete the boot process a diagnostic card can be attached to the computer to read I O port 0080h Supermicro p n AOM SPI80 V For information on AMI updates please refer to http www ami com products ...

Page 112: ...to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard here where you may download individual drivers and utilities After creating a CD DVD with the ISO files insert the disk into the CD DVD drive on your system and the following screen should appear Note 1 Click the icons showing a hand writing on paper to view the readme files for each item...

Page 113: ...nsumption and fan speed and provides alerts via email or the Simple Network Management Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With the SuperDoctor 5 Management Server SSM Server you can remotely control the power status and reset chassis intrusion for multiple systems with SuperDoctor 5 or IPMI ...

Page 114: ...icro com about policies safety_information cfm Battery Handling 電池の取り扱い 電池交換が正しく行われなかった場合 破裂の危険性があります 交換する電池はメーカーが推 奨する型 または同等のものを使用下さい 使用済電池は製造元の指示に従って処分して下さい 警告 电池更换不当会有爆炸危险 请只使用同类电池或制造商推荐的功能相当的电池更换原有电 池 请按制造商的说明处理废旧电池 警告 電池更換不當會有爆炸危險 請使用製造商建議之相同或功能相當的電池更換原有電池 請按 照製造商的說明指示處理廢棄舊電池 Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr Ersetzen Sie die Batterie nur durch den gleich...

Page 115: ...orden 경고 배터리가 올바르게 교체되지 않으면 폭발의 위험이 있습니다 기존 배터리와 동일하거나 제조사에서 권장하는 동등한 종류의 배터리로만 교체해야 합니다 제조사의 안내에 따라 사용된 배터리를 처리하여 주십시오 Advertencia Existe peligro de explosión si la batería se reemplaza de manera incorrecta Reemplazar la batería exclusivamente con el mismo tipo o el equivalente recomendado por el fabricante Desechar las baterías gastadas según las instrucciones del fabricante אזהרה להחליף יש תקינ...

Page 116: ... recyclage de ce produit sont généralement soumis à des lois et ou directives de respect de l environnement Renseignez vous auprès de l organisme compétent Waarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming met alle nationale wetten en reglementen 경고 이 제품은 해당 국가의 관련 법규 및 규정에 따라 폐기되어야 합니다 Warning Ultimate disposal of this product should be handled acco...

Page 117: ...onsists of a recovery BIOS block and a main BIOS block a main BIOS image The boot block contains critical BIOS codes including memory detection and recovery codes for the user to flash a new BIOS image if the original main BIOS image is corrupted When the system power is on the boot block codes execute first Once it is completed the main BIOS code will continue with system initialization and bootu...

Page 118: ...a USB attached device follow the instructions below 1 Using a different machine copy the Super ROM binary image file into the disc Root Directory of a USB device or a writeable CD DVD Note If you cannot locate the Super ROM file in your driver disk visit our website at www supermicro com to download the BIOS image into a USB flash device and rename it Super ROM for BIOS recovery use 2 Insert the U...

Page 119: ...ou want to start the BIOS recovery If you decide to proceed with BIOS recovery follow the procedures below 5 When the screen as shown above displays use the arrow keys to select the item Proceed with flash update and press the Enter key You will see the BIOS recovery progress as shown in the screen below Note Do not interrupt the BIOS flashing process until it has completed ...

Page 120: ...kage into a USB flash drive 8 Press Del continuously to enter the BIOS setup utility Set the item Boot Option 1 to UEFI AP UEFI Built in EFI Shell Press F4 to save the settings and exit the BIOS setup utility 6 After the BIOS recovery process is completed press any key to reboot the system ...

Page 121: ...upt this process until the BIOS flashing is complete 10 The screen above indicates that the BIOS update process is completed When you see the screen above unplug the AC power cable from the power supply clear CMOS and plug the AC power cable in the power supply again to power on the system 11 Press Del continuously to enter the BIOS setup utility 12 Press F3 to load the default settings 13 After l...

Page 122: ...ur due to a software tool issue see image below or an unexpected power outage during BIOS updates BIOS Boot Block Corruption Occurrence When a BIOS boot block is corrupted due to an unexpected power outage or a software tool malfunctioning during BIOS updates you can still reboot the system by closing pins 2 and 3 using a cap on jumper JBR1 When JBR1 is set to pins 2 and 3 the system will boot fro...

Page 123: ...mper JBR1 1 Power down the system 2 Close pins 2 3 on jumper JBR1 and power on the system 3 Follow the BIOS recovery SOP listed in the previous chapter Appendix D 4 After completing the steps above power down the system 5 Close pins 1 2 on jumper JBR1 and power on the system ...