Summary of Contents for FirstSave AED 3g

Page 1: ...Power heart G3 Manual Get an original copy of the Cardiac Science FirstSave Powerheart G3 Defibrillator Operators Guide for manufacturer information about service available accessories and how to use...

Page 2: ...WARNING Electric Shock and Fire Hazard Do not connect any telephones or unauthorized connectors to the socket on this equipment Instructions for Use...

Page 3: ...ormation page 23 AED DESCRIPTION The AED is a self testing battery operated automated external defibrillator AED After applying the AED s pads to the patient s chest the AED automatically analyzes the...

Page 4: ...odels They share a basic set of features and differences are noted throughout the manual The AED warranty for defects in materials or workmanship is 7 years from date of purchase For the full warranty...

Page 5: ...0C When this STATUS INDICATOR is GREEN the AED is RescueReady This indicates the AED self tests have verified the following Battery has an adequate charge Pads are properly connected and are functiona...

Page 6: ...lace the battery right away A new battery typically takes 10 seconds to charge the AED to maximum energy Output voltage 12VDC max Batteries are non rechargeable Lithium contents 9 2g max Check local r...

Page 7: ...THE PADS Self adhesive disposable pads Minimum combined surface area 228cm2 Extended length of lead wire 1 3m AUDIBLE MAINTENANCE INDICATOR For all Cardiac Science AEDs 9300 series When the daily wee...

Page 8: ...he patient to Advanced Life Support personnel prepare the AED for the next rescue 1 Retrieve the rescue data stored in the internal memory of the AED 2 Connect a new pair of pads to the AED 3 Close th...

Page 9: ...The AED when connected to the patient s chest by the pads can withstand the effects of an externally applied defibrillation shock CE Mark This equipment conforms to essential requirements of the Medic...

Page 10: ...equipped with Multiple Rescue software A red indicator with a BLACK X means the AED requires operator attention or maintenance and is not RescueReady Does not apply to 9300C A green indicator without...

Page 11: ...ing concentrated oxygen Upper and lower temperature limits Device model number battery model number Lot number Lithium sulfur dioxide Serial communication port Additional information is provided in th...

Page 12: ...Humidity 5 to 95 non condensing Pressure 57kPa 15 000ft to 103kPa 500ft SHIPMENT AND TRANSPORT ENVIRONMENTAL CONDITIONS for up to 1 week Atmosphere Condition Temperature 30 C to 65 C 22 F to 149 F Hu...

Page 13: ...22 2 No 601 1 M90 Electrical Construction Safety and Performance Electromagnetic Compatibility EMC IEC 60601 1 1998 Amendments 1 1991 2 1995 IEC 60601 2 4 2002 ANSI AAMI DF 39 1993 IEC 60601 1 2 2001...

Page 14: ...ection 36 202 2 6KV contact discharge 8KV air gap discharge ENVIRONMENTAL CONDITIONS Condition Standard or Compliance Free Fall Drop IEC 60068 2 32 1975 AM 2 1990 1 meter Bump IEC 60068 2 29 1987 40g...

Page 15: ...er 8 years of age or weighs less than 55lbs 25kg the AED should be used with the Pediatric Attenuated Defibrillation Pads Therapy should not be delayed to determine the patient s exact age or weight S...

Page 16: ...hest Ensure the skin site is clean and dry Dry the patient s chest and shave excessive hair if necessary STEP 3 PLACE PADS Tear open pad package and remove pads Peel one pad from plastic liner Place o...

Page 17: ...CK DELIVERED IT IS NOW SAFE TO TOUCH THE PATIENT For the Powerheart AED G3 Automatic 9300A The voice text prompts will guide you through DO NOT TOUCH PATIENT ANALYZING RHYTHM If a shockable rhythm is...

Page 18: ...tify potential hazards using symbols and words to explain what could potentially harm you the patient or the Cardiac Science AED G3 SAFETY TERMS AND DEFINITIONS The triangle attention symbol shown bel...

Page 19: ...the following Do not touch the patient unless performance of CPR is indicated Do not touch metal objects in contact with the patient Keep defibrillation pads clear of other pads or metal parts in con...

Page 20: ...fire and explosion hazard do not burn or incinerate the battery CAUTION Use only Manufacturer Approved Equipment Using batteries pads cables or optional equipment other than those approved by the man...

Page 21: ...e patient s cardiac rhythm Stop all motion or vibration before attempting a rescue CAUTION Systems Statement Equipment connected to the analog and digital interfaces must be certified to the respectiv...

Page 22: ...load The Biphasic Truncated Exponential BTE waveform uses variable energy The actual energy delivered will vary with the patient s impedance and the device will deliver a shock when impedance is betw...

Page 23: ...aveform Phase 1 Phase 2 Patient s Impedance Ohms Voltage Volts Duration ms Voltage Volts Duration ms Energy Joules 25 1393 3 3 743 3 2 145 196 50 1420 4 5 909 3 2 128 173 75 1430 5 8 973 3 2 116 156 1...

Page 24: ...e 1 Phase 2 Patient s Impedance Ohms Voltage Volts Duration ms Voltage Volts Duration ms Energy Joules 25 1609 3 3 858 3 2 193 260 50 1640 4 5 1050 3 2 170 230 75 1651 5 8 1124 3 2 155 209 100 1656 7...

Page 25: ...owable energy range Phase 1 Phase 2 Patient s Impedance Ohms Voltage Volts Duration ms Voltage Volts Duration ms Energy Joules 25 1869 3 3 997 3 2 260 351 50 1906 4 5 1220 3 2 230 311 75 1918 5 8 1306...

Page 26: ...othell WA 98021 U S A MDSS GmbH Schiffgraben 41 D 30175 Hannover Germany FirstSave Powerheart STAR IntelliSense RescueLink RescueReady and RHYTHMx are trademarks and registered trademarks of Cardiac S...

Page 27: ...P N 112 0036 401 Rev A...