Page 28
Menu-Nr. 7
Set offset (sensitivity) for learned opening force
Attention:
The learning power limit is set automatically.Only change it if necessary (error No. 17).
Always test the max. allowed operating forces according to EN 12445 and EN 12453!
1.
Nr. 7 blinks.
2.
Use + or - to change offset.
Deactivated:
1
minimum offset:
2
maximum offset:
16
Possible Settings:
3.
Press P to store and go to Menu-Nr. 8.
Menu-Nr. 8
Set offset (sensitivity) for learned closing force
Attention:
The learning power limit is set automatically.Only change it if necessary (error No. 17).
Always test the max. allowed operating forces according to EN 12445 and EN 12453!
1.
Nr. 8 blinks.
2.
Use + or - to change offset.
Deactivated:
1
minimum offset:
2
maximum offset:
16
Possible Settings:
3.
Press P to store and go to Menu-Nr. 9.
11. Advanced settings
Page 17
9.4
Operator Programming - Basic Settings
Menu Overview:
1.
Set door OPEN position
2.
Set door CLOSED position
3.
Program hand transmitter
To Set Up The Operator:
Attention:
Make sure the internal receiver is installed (see page 13).
Press transmitter button once before you start with operator programming – basic settings
Menu-Nr. 1:
Set door open position
Operator is in normal operating mode.
1.
Press P for 3 seconds until Nr. 1 blinks.
2.
Release P when Nr. 1 blinks.
3.
To move the garage door to desired fully open position press AND hold the + (open) button until
desired door open position is reached. For fine-tuning use the + (open) and - (close) buttons.
Advice:
The reference point has to be passed 1x. All LED segments will switch OFF for 1sec. when limit switch is
activated WHILE in programming mode. Refer to Chapter 9.1 when motor is in operational mode.
4.
Once door position is correct press P to store and go to Menu-Nr. 2.
Menu-Nr. 2:
Set door close position
1.
Nr. 2 blinks.
2.
To move the garage door to desired fully CLOSED position press & hold the - until desired door close
position is reached.
For fine-tuning use the - (close) and + (open) buttons.
Advice:
The reference point has to be passed 1x. All LED segments will switch OFF for 1sec. when limit switch is
activated WHILE in programming mode. Refer to Chapter 9.1 when motor is in operational mode.
3.
Once door position is correct press P to store and go to Menu-Nr. 3.
9.