Version 08.05.2019
MIB-Entry-5inch (180514)
CI-RL5-MIB2-E
P
a
g
e
9
2.3.2.
Connection - 50pin ribbon cables
Fold upwards the black hinge of the factory ribbon cable base to unlock the original
brown colored 50pin ribbon cable of the factory PCB.
Carefully pull out the original 50pin ribbon cable in arrow direction.
Note: The original short ribbon cable is made by stiff material. To avoid any breakage it
mustn’t be folded back to much, either while the installation nor with the final assembly.
Connect the daughter PCB’s 50pin ribbon cable
„CAR-IN“
to the previously become
free 50pin ribbon cable base of the factory PCB. Make sure that the connector pins
are faced to the platinum.
After a check of its perfect position, close the ribbon cable base’s lock by folding
downwards the black hinge, to fix the connection again.