Instruction manual C856i
Please keep this instruction manual for future reference
32
INSTALLATION
Selection of installation equipment
Cut out the work surface according to the sizes shown in the drawing. For the
purpose of installation and use, a minimum of 5 cm space shall be preserved
around the hole. Be sure the thickness of the work surface is at least 30mm. Please
select heat-resistant work surface material to avoid larger deformation caused by
the heat radiation from the hotplate. As shown below:
L (mm)
W (mm)
H (mm)
D (mm)
A (mm)
B (mm)
X (mm)
590
520
60
56
564
494
50
WARNING
Always ensure the hob is well ventilated and the air inlet and outlet are not
blocked. Ensure the induction hob is in good working order. As shown below
A (mm)
B (mm)
C (mm)
D
E
760
50
20
Air intake
Air exit (5mm)
NOTE:
The safety distance between the hob and the cupboard above should be at least
760mm.