28 Instruction manual C775G, C750G, C768G
Please keep this instruction manual for future reference
G A S A D J U S T M E N T
Neglect of this mark may result in severe personal injury or death.
Danger/Warning
Neglect of this mark may result in minor personal injury or
property damage.
No naked flames
No Access
Must Do
DANGER
If gas appears to be leaking, take the following actions:
-
Do not turn on the light.
-
Do not switch any electrical appliance on or off and do not touch any electric plug.
-
Do not use a telephone.
1 Stop using the product and close the middle valve.
2 Open the window to ventilate.
3 Contact our service centre or gas supplier by using a phone outside.
* The gas contains mercaptan, so that you can smell the gas leak (smell of rotten garlic or egg) even where only
1/1000 of the gas is in the air.
WARNING SYMBOLS
Caution
Take precautions on the operations and adjustments to be carried our when converting
from one gas to another.
All work must be carried out by a qualified technician.
Before you begin, turn off the gas and electricity supply to the appliance.
C H A N G E T H E I N J E C TO R O F T H E B U R N E R S
Remove the pan support, Burner lid and Flame spreader.
Unscrew the injector using a 7mm box spanner and replace it
with the stipulated injector for new gas supply.
Carefully reassemble the all components.
After injectors are replaced, it is advisable to strongly tighten
the injector in place.
Remove the pan support, Burner lid and Flame spreader.
Unscrew the injector using a 7mm box spanner and replace it with the
stipulated injector for new gas supply.
Carefully reassemble the all components.
After injectors are replaced, it is advisable to strongly tighten the injector
in place.
Injector
Control handle
Tap
Sealing ring
Tap
by-pass screw
G A S A D J U S T M E N T
Take precautions on the operations and adjustments to be carried our when converting from
one gas to another.
All work must be carried out by a qualified technician.
Before you begin, turn off the gas and electricity supply to the appliance.
CHANGE THE INJECTOR OF THE BURNERS
Do not dismantle the tap shaft: in the event of a malfunction, change the whole tap.
Before placing the burners back on top, make sure the injector is not blocked.
A full operational test and a test for possible leakages must be carried out after the gas
conversion (such as soap water or a gas detector).
After completing the conversion, a qualified technician or installer must mark ‘V’ next
to the correct gas category to match with the setting on the Rating Label. Make sure to
remove the previous ‘V’ mark.
CHANGE THE INJECTOR OF THE BURNERS
1. Turn the taps down to minimum.
2. Remove the knob from the tap and place a small bladed
screwdriver in the centre of the tap shaft.
3. The correct adjustment is obtained when the flame has a length
of about 3-4mm.
- For butane/propane gas, the adjusting screw must be tightly
screwed in.
- Refit the control knob.
- Make sure that the flame does not go out by quickly turning
from maximum flow to minimum flow. If it does, then remove the
control knob and make further adjustments to the gas flow, testing it
again once the adjustment has been made.
4. Repeat this process for each one of the gas taps.