POSITIONING (C768G)
-
An oven must have forced ventilation to install a hob above it.
-
Check the dimensions of the oven in the installation manual.
-
The cut out size must be as shown in the drawing relevent to the model being installed.
45 mm
> The edges of the hob must be a minimum distance of 60mm from a side or rear wall.
> 700mm between the highest point of the hob surface (including the burners) and the underside of any horizontal
surface directly above it.
> 400mm between the hob surfaces, providing that the underside of the horizontal surface is in line with the
outer edge of the hob. If the underside of the horizontal surface is lower than 400mm, then it must be
at least
50mm away from the outer edges of the hob.
> 50mm clearance around the appliance and between the hob surface and any combustible materials.
> You must have a gap of at least 25mm and at most 74mm between the underneath of the appliance and any
surface that is below it.
This appliance is to be built into a kitchen unit or 600mm worktop, providing the following minimum distances are allowed:
CLEARANCES REQUIRED
WHEN FITTING THE HOB WITH A COOKER HOOD ABOVE
400mm
560mm
490mm
400mm
7
200mm
Min.
CLEARANCES REQUIRED
WHEN FITTING THE HOB WITHOUT A COOKER HOOD ABOVE
400mm
490mm
400mm
60mm
60mm
750mm
560mm
00mm
700mm
200mm
Min.
› An oven must have forced ventilation to install a hob above it.
› Check the dimensions of the oven in the installation manual.
› The cut out size must be as shown in the drawing relevent to the model being installed.