Capital fireplaces Tucana 600 Inset Instructions Manual Download Page 6

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

Installation      

Key   Installation   Requirements   

 

We   recommend   that   this   stove   is   fitted   in   a   tiled   or   stone   frame,   or   a   suite.      It   is   possible   to   install   the   stove   directly   in   the   wall   using   high   temperature   render   
and   plaster,   however   even   this   can   show   hairline   cracks   due   to   the   high   temperatures   that   can   be   generated   above   the   stove.   

 

There   should   be   no   gaps   behind   or   to   the   side   of   the   stove   in   order   to   prevent   chimney   debris   collecting.   

 

If   there   is   a   gap   behind   the   stove   it   should   be   filled   with   vermiculite   granules   topped   with   mortar.      The   fire   should   have   an   absolutely   airtight   seal   against   the   
fireplace.    When    fitting    this    stove    with    a    trim,    a    gap    will    be    required    between    the    flange    and    back    panel    to    allow    the    trim    to    be    attached,    please    see    the   
relevant   trim   instructions   for   further   guidance.   

 

A   non-­‐combustible   base   should   be   created   for   the   stove   to   sit   upon.   

 

The    appliance    should    be    installed    on    floors    with    an    adequate    load-­‐bearing    capacity.        If    an    existing    construction    does    not    meet    this    pre-­‐requisite,    suitable   
measures   (e.g.   load   distributing   plate)   should   be   taken   to   achieve   it.   

Regarding   installations   in   rooms   with   extractor   fans:   
For   solid   fuel   appliances:   avoid   installing   extract   ventilation   in   the   same   room.   If   mechanical   extraction   is   unavoidable   then   seek   specialist   advice   to   ensure   the   installation   
is   tested   for   the   safe   operation   of   the   appliance.   

A   suitable   test   would   be   to   check   for   spillage   when   appliances   are   subjected   to   the   greatest   possible   depressurisation.   A   prerequisite   for   this   condition   is   that   all   external   
doors,   windows   and   other   adjustable   ventilators   to   outside   are   closed.   The   depressurisation   at   the   appliance   will   depend   on   the   particular   combination   of   fans   in   
operation   (fans   in   the   room   containing   the   appliance   and   fans   elsewhere   in   the   building)   and   the   pattern   of   open   internal   doors,   hatches   etc.   which   is   established   at   the   
time   of   the   test   (when   fans   should   be   on   their   maximum   useable   setting),   and   the   specific   combination   causing   the   greatest   depressurisation   at   the   appliance   depends   
upon   the   circumstances   in   each   case.   Several   tests   (which   should   include   a   test   with   the   door   leading   into   the   room   of   installation   closed   and   all   fans   in   that   room   
switched   on)   may   therefore   be   necessary   to   demonstrate   the   safe   operation   of   the   appliance   with   reasonable   certainty.   The   effect   of   ceiling   fans   should   be   checked   
during   the   tests.   Extra   ventilation   should   be   supplied   if   tests   show   that   this   is   necessary.   

   Fixing   Stove   in   Place   

A   clearance   of   at   least   600mm   in   width   is   required   to   fit   the   stove;   it   is   designed   
to   fit   under   most   lintels.   

The   flue   collar   is   secured   in   place   by   two   M6   nuts   that   can   be   accessed   from   the   
inside   of   the   stove.      The   collar   should   be   removed   before   the   stove   is   positioned   
and   then   re-­‐attached   (for   details   of   how   to   remove   stove   internals   to   access   flue   
collar   see   the   “Maintenance”   section   on   previous   page).   

It   is   the   responsibility   of   the   installer   to   confirm   if   a   flue   liner   is   required,   see   the   
“Your   Chimney”   section   on   previous   page   for   more   details.   

   

   

Some   suggested   methods   of   installation   are   detailed   below:            

   

   

   

Our   stove   designs   are   registered   at   the   UK   patent   office   and   protected   by   Copyright   ©   and   UK   Design   Right.      Certain   parts   are   UK   Patent   Applied   For.      This   document   issued   06/01/2015.      We   are   always   striving   to   improve   these   

products   and   may   change   their   specification   without   notice.   

   

   

In   specifically   designed   suites:                                                                                                                                                                                       

   

   

With   specifically   designed   tile   sets:   

   

Key   Points   for   

this   installation:   

The   slips   must   be   

backfilled   

A   choice   of   trims,   

either   bevelled   or   

square   profiled,   

can   be   used.   

   

Key   Points   for   this   installation:   

The   wall   must   be   structurally   

sound.   

All   surrounding   plasterwork   must   

be   sound.   

It   is   recommended   that   the   wall   

above   the   stove   is   rendered   and   

plastered   using   products   with   a   

high   temperature   resistance.      

Even   if   this   precaution   is   taken   it   

should   be   noted   that   over   firing   

the   stove   can   still   result   in   

hairline   cracks   appearing   due   to   

the   excessive   temperatures   

generated.   

High   temperature   adhesive   

should   be

   

used   and   applied   to   

the   whole   tile,   ask   your   retailer   

for   a   suitable   product.   

   

Key   points   for   this   installation:   

The   wall   must   be   structurally   sound.   

All   surrounding   plasterwork   must   be   

sound.   

A   specifically   designed   bracket   is   

included   with   the   frame   and   must   be   

chased   into   the   wall   to   a   depth   of   10mm   

such   that   the   bottom   of   the   slip   is   

160mm   below   the   bottom   of   the   stove   

(excluding   the   trim).      It   is   the   

responsibility   of   the   fitter   to   ensure   that   

adequate   fixings   are   used   such   that   the   

bracket   is   securely   fixed   to   the   wall   and   

can   take   the   weight   of   the   whole   frame.   

Suitable   high   temperature   adhesive   

must   be   used   and   must   be   applied   to   the   

whole   rear   surface   of   each   slip   of   the   

frame.      

   

With   specifically   designed   frames:   

   

Summary of Contents for Tucana 600 Inset

Page 1: ...Stove Instructions Tucana 600 Inset Stove Vega 600 Inset ...

Page 2: ...th of the grate It is best to keep the fuel towards the back of the grate during these early stages Place a small kiln dried log less than 15 moisture on top of the kindling and close the door Wet wood will cause the stove window to blacken Do not cover the tertiary air holes the small holes located at the rear of the firebox above the back brick Once the log starts to burn close the primary botto...

Page 3: ... regulations and with these instructions Signed Date Flue Draught measured on commissioning Fuel used on commissioning The Clean Air Act 1993 and Smoke Control Areas Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control area It is an offence to emit smoke from a chimney of a building from a furnace or from any fixed boiler if...

Page 4: ...oss section not less than 0 018m e g 150mm dia and never more than 0 14m e g 375 x 375mm Being free from even the slightest crack or source of leakage Having no bends sharper than 45 Being entirely free of obstructions and swept by a qualified chimney sweep Being connected to only this stove Being of thick masonry or otherwise adequately insulated Conforming to local building regulations Special r...

Page 5: ...the chimney shut the top air vent and stove door evacuate the premises and call the fire brigade Maintenance Regular cleaning and maintenance will help prolong the life of many of the replaceable components in your stove Before carrying out any cleaning or maintenance tasks ensure that the stove is totally cold The stove internals should be removed in the following order Front bar Base vermiculite...

Page 6: ...e operation of the appliance with reasonable certainty The effect of ceiling fans should be checked during the tests Extra ventilation should be supplied if tests show that this is necessary Fixing Stove in Place A clearance of at least 600mm in width is required to fit the stove it is designed to fit under most lintels The flue collar is secured in place by two M6 nuts that can be accessed from t...

Page 7: ...e So fibreglass rope can be used to fill the gap between collar and flue Once the stove is in the fireplace the installer can reach up through the opening in the roof of the stove and use the hook handle to pull the collar down into posi on and bolt it in place A er securing the collar the hooks handles can be broken off from the base disc by working them le and right un l they snap off If you are...

Page 8: ...l 01462 813138 Freefax 0800 980 4847 Email sales capitalfireplaces co uk Website www capitalfireplaces co uk For North of England sales please contact Percy Doughty Co Ltd Imperial Point Express Trading Estate Stone Hill Road Farnworth BL4 9TN Tel 01204 868550 Fax 01204 868551 Email sales percydoughty com Website www percydoughty com ...