Quick   Start   Guide   

To   get   the   most   out   of   your   stove   you   should   take   the   time   to   read   the   instructions   provided.   If   for   

any   reason   you   don’t   have   these   instructions   contact   your   retailer   and   request   a   copy.   

   

This    guide    is    intended    to    help    you    get    the    best    possible    fire    started.        Even    if    you    have    previous   

experience   with   stoves,   all   makes   and   models   vary   and   the   information   below   will   help   you   gain   the   

optimum   performance   from   your   new   stove.   

   

   

Make   sure   both   the   primary   (bottom)   and   secondary   
(top)   valves   are   open.      The   open   position   is   with   both   
controls   fully   to   the   left   on   the   glass   fronted   and   the   
top   valve   to   the   right   and   the   bottom   turned   
anticlockwise   on   the   Traditional.   

To   start   a   fire,   create   a   small   ‘wigwam’   of   kindling   
towards   the   back   of   the   grate   and   light   it   using   a   
single   firelighter.   

Close   the   door   and   wait   until   the   firelighter   burns   
away   and   the   kindling   is   fully   ignited.   

   

Open   the   door   and   use   a   poker   to   lay   the   kindling   
across   the   width   of   the   grate.      

It   is   best   to   keep   the   fuel   towards   the   back   of   the   
grate   during   these   early   stages.   

Place   a   small   kiln   dried   log   (less   than   15%   moisture)   
on   top   of   the   kindling   and   close   the   door.   

Wet   wood   will   cause   the   stove   window   to   blacken.   

Do   not   cover   the   tertiary   air   holes   (the   small   holes   
located   at   the   rear   of   the   firebox   above   the   back   
brick).   

   

Once   the   log   starts   to   burn   close   the   primary   
(bottom)   valve   by   sliding   it   to   the   right   on   the   glass   
fronted   and   turning   clockwise   on   the   traditional.   

If   you’re   continuing   to   burn   wood   use   the   secondary   
(top)   valve   to   control   the   fire,   we   usually   recommend   
half   closing   it   but   every   installation   will   vary   so   try   
different   settings   until   you   find   one   you’re   happy   
with.      If   you’re   burning   solid   fuel,   such   as   anthracite,   
wait   until   you   have   a   bed   of   hot   ash   and   then   add   
your   fuel.         

The   settings   for   solid   fuel   are   the   opposite   to   wood,   
fully   close   the   secondary   (top)   valve   and   control   the   
rate   of   burn   using   the   primary   (bottom)   valve.   

Don’t   over   fill   the   firebox,   this   is   a   very   efficient   
stove   and   will   generate   plenty   of   heat   with   a   small   
amount   of   fuel.   

   

Primary   Valve   

Secondary   Valve   

Secondary   Valve   

Primary   Valve   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

   

This   document   is   to   be   left   with   the   householder   after   installation.   

All   our   stoves   exceed   the   safety   and   performance   requirements   of   European   Standards.   

Independently   tested   by   SGS   (Notified   Laboratory   No:   0608)   in   2012.   

Intermittent   wood   burning   roomheater   for   installation   with   a   single   dedicated   chimney.                                                                                                                                                

   

   

   

Fuel   

Wood   (Beech)   

Test   Standard   

NEN   EN   13229:2001   &   NEN   EN   13229-­‐A2:2004   

Test   Cycle   

1.20kg   over   0.80hrs   

Settings   

Air   Slide   at   50%   

Flue   Draught   Pa   

12.2   

Efficiency   %   

76.30%   

Recommended   Rating   kW   

4.9   

Mean   Flue   Gas   Temp   Rise   °K   

276   

Minimum   air   entry   requirement   

2500mm²   

Minimum   Clearance   to   combustibles   

See   table   below   

Weight   

60kg   

Flue   outlet   size   

125mm   

Emissions   as   if   O2   =   13%   

   

NOx   mg/mᶟ   

91   

CO   %   

0.19   

CxHy   mg/mᶟ   

148   

Gas   flow   g/sec   

5.1   

Smoke   Emission   g/hr   

0.7   

   

Calculated   required   minimum   insulation   for   T   <   65°C   above   ambient   temperature   (Silcal   1000)   

   

Back   wall   

116mm   

Side   wall   

112mm   

Floor   

44mm   

Ceiling   

nc   

nc:   non   combustible   only   (ceiling   of   chamber).   Appliance   must   be   750mm   below   ceiling   of   room   

   

Note:      Between   appliance   and   insulation   a   gap   of   1   cm   was   present.   

   

   

This   stove   must   be   installed   and   commissioned   by   a   fully   qualified   registered   engineer,   or   the   building   inspector   must   be   informed.      For   more   details   contact   your   local   

authority.   

   

This   document,   when   completed   by   the   installer,   constitutes   part   of   a   ‘Hearth   Notice’   for   purposes   of   Building   Law.      It   must   be   left   with   the   householder   and   placed   

where   it   can   easily   be   found.   

   

Installed   at   Location:   ....................................................................................................               By:........................................................................................................................   

   

I   definitively   assert   that   this   installation   is   safe,   has   been   lit   and   demonstrated   to   the   householder,   conforms   with   current   building   regulations   and   with   these   

instructions.   

   

Signed:.............................................................................................................................   Date:.......................................................................................................................   

   

Flue   Draught   measured   on   commissioning:   .....................................................................   

   

Fuel   used   on   commissioning:.............................................................................................   

   

   

   

   

   

   

   

   

   

   

   

The   Clean   Air   Act   1993   and   Smoke   Control   Areas   

   

Under   the   Clean   Air   Act   local   authorities   may   declare   the   whole   or   part   of   the   district   of   the   authority   to   be   a   smoke   control   area.   It   is   an   offence   to   emit   smoke   from   a   chimney   of   a   building,   from   a   furnace   or   from   any   

fixed   boiler   if   located   in   a   designated   smoke   control   area.   It   is   also   an   offence   to   acquire   an   "unauthorised   fuel"   for   use   within   a   smoke   control   area   unless   it   is   used   in   an   "exempt"   appliance   ("exempted"   from   the   

controls   which   generally   apply   in   the   smoke   control   area).      

The   Secretary   of   State   for   Environment,   Food   and   Rural   Affairs   has   powers   under   the   Act   to   authorise   smokeless   fuels   or   exempt   appliances   for   use   in   smoke   control   areas   in   England.   In   Scotland   and   Wales   this   power   

rests   with   Ministers   in   the   devolved   administrations   for   those   countries.   Separate   legislation,   the   Clean   Air   (Northern   Ireland)   Order   1981,   applies   in   Northern   Ireland.   Therefore   it   is   a   requirement   that   fuels   burnt   or   

obtained   for   use   in   smoke   control   areas   have   been   "authorised"   in   Regulations   and   that   appliances   used   to   burn   solid   fuel   in   those   areas   (other   than   "authorised"   fuels)   have   been   exempted   by   an   Order   made   and   

signed   by   the   Secretary   of   State   or   Minister   in   the   devolved   administrations.   

Further   information   on   the   requirements   of   the   Clean   Air   Act   can   be   found   here:   http://smokecontrol.defra.gov.uk/      

Your   local   authority   is   responsible   for   implementing   the   Clean   Air   Act   1993   including   designation   and   supervision   of   smoke   control   areas   and   you   can   contact   them   for   details   of   Clean   Air   Act   requirements                                                                        
This   stove   has   been   recommended   as   suitable   for   use   in   smoke   control   areas   when   burning   wood.   

   

Summary of Contents for Tucana 600 Inset

Page 1: ...Stove Instructions Tucana 600 Inset Stove Vega 600 Inset ...

Page 2: ...th of the grate It is best to keep the fuel towards the back of the grate during these early stages Place a small kiln dried log less than 15 moisture on top of the kindling and close the door Wet wood will cause the stove window to blacken Do not cover the tertiary air holes the small holes located at the rear of the firebox above the back brick Once the log starts to burn close the primary botto...

Page 3: ... regulations and with these instructions Signed Date Flue Draught measured on commissioning Fuel used on commissioning The Clean Air Act 1993 and Smoke Control Areas Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control area It is an offence to emit smoke from a chimney of a building from a furnace or from any fixed boiler if...

Page 4: ...oss section not less than 0 018m e g 150mm dia and never more than 0 14m e g 375 x 375mm Being free from even the slightest crack or source of leakage Having no bends sharper than 45 Being entirely free of obstructions and swept by a qualified chimney sweep Being connected to only this stove Being of thick masonry or otherwise adequately insulated Conforming to local building regulations Special r...

Page 5: ...the chimney shut the top air vent and stove door evacuate the premises and call the fire brigade Maintenance Regular cleaning and maintenance will help prolong the life of many of the replaceable components in your stove Before carrying out any cleaning or maintenance tasks ensure that the stove is totally cold The stove internals should be removed in the following order Front bar Base vermiculite...

Page 6: ...e operation of the appliance with reasonable certainty The effect of ceiling fans should be checked during the tests Extra ventilation should be supplied if tests show that this is necessary Fixing Stove in Place A clearance of at least 600mm in width is required to fit the stove it is designed to fit under most lintels The flue collar is secured in place by two M6 nuts that can be accessed from t...

Page 7: ...e So fibreglass rope can be used to fill the gap between collar and flue Once the stove is in the fireplace the installer can reach up through the opening in the roof of the stove and use the hook handle to pull the collar down into posi on and bolt it in place A er securing the collar the hooks handles can be broken off from the base disc by working them le and right un l they snap off If you are...

Page 8: ...l 01462 813138 Freefax 0800 980 4847 Email sales capitalfireplaces co uk Website www capitalfireplaces co uk For North of England sales please contact Percy Doughty Co Ltd Imperial Point Express Trading Estate Stone Hill Road Farnworth BL4 9TN Tel 01204 868550 Fax 01204 868551 Email sales percydoughty com Website www percydoughty com ...

Reviews: