There are two sets of jumper in the alarm, respectively are the volume control jumper (plug in for 

big  volume)  and  tamper  jumper (plug  in  to  open  warning). Plug  in or  remove  the jumper can 

switch between different function settings (Fig. 8 & 9). 

 

Fig.8 

 

Fig.9 

Note: 

Tamper is designed to start the alarm to notify users and deter vandals when alarm is 

force  forcibly  removed.  When  the  switch  is  pressed  for  more  than 3  seconds  later,  tamper 

function will start. If you switch off again at this time (it is equal to remove it from the wall 

after installation), then an alarm is raised, and flash and the alarm will last for 3 minutes. 

Safety Notice 

 

Don't make the device directly to the window/fan/air-conditioner or sunlight. 

 

Do not install the device above or facing any source of heat directly, such as fires, radiators, 

Summary of Contents for CT-SMZW2008-ES

Page 1: ...settings Inclusion of this alarm on other manufacture s Wireless Controller menu allows remote turn on of connected modules when the detector is triggered After this product included into the network when the associated device such as sensor is triggered the alarm can send out alarm after receiving the wireless message The alarm is a combination of alarm and flash the alarm volume can reach 100 db...

Page 2: ... volume can reach 100 db and 90 db Specifications Radio protocol Z Wave Operation Frequency 868 42MHz 908 42 MHz SP814 2 921 42 MHz SP814 9 Power supply DC6V 600mA 1 5V LR14 x 4 Battery life 1 year RF range 25m in an open area of the wireless controller and the latest line of sight between Z Wave receiving module Alarm volume 100 db and 90 db Operation As shown below respectively alarm front side ...

Page 3: ...ssed 4 When prompt a message Request Access Success please go to the device list interface and refresh the device list the device will be displayed Z WAVE NETWORK EXCLUSION 1 Make sure the device is connected to the power supply 2 Remove the device on the APP then click finish 3 Pressing link key 3 times within 1 5 second The green LED lights up and sends out beep sound when link key is pressed 4 ...

Page 4: ...nds out beep sound when link key is pressed 3 Within 1 second press and hold the link key about 5 seconds until the LED light turns off A long beep is sounded for 5 seconds and the LED light turns off 4 IDs are excluded and all of preset value will be reset to factory default LED 2 second on 2 second off Beep sound every 10 seconds 0 1 seconds each ring Installation Instructions It s recommended t...

Page 5: ...th cable wire slot which can connect with the transformer connection wire If you use the transformer please insert the transformer coupling into the DC hole then connect the wire with wire slot Fig 4 5 Fig 4 Fig 5 3 Using the back cover as the example identified three screw holes on the wall Use the attached plastic gecko and screws fixed the back cover on the wall Fig 6 Fig 6 4 Put the alarm main...

Page 6: ...er is designed to start the alarm to notify users and deter vandals when alarm is force forcibly removed When the switch is pressed for more than 3 seconds later tamper function will start If you switch off again at this time it is equal to remove it from the wall after installation then an alarm is raised and flash and the alarm will last for 3 minutes Safety Notice Don t make the device directly...

Page 7: ...d by the detector is consistent with actual ambient illumination Do not locate the detector in shadowy place Where possible mount the detector so that the logical path of an intruder would cut across the fan pattern rather than directly towards the detector In order to obtain the best results please put the detector directly facing the entrance ...

Reviews: