background image

            

www.cap-homey.com 

                            User Manual

 

CAP-TECH INTERNATIONAL CO.,LTD. 

If the device is online, directly perform steps 1-5, if the device is offline, need interruption of the 

device power supply first, and then perform step 1-5. 

DEVICE RESET 

Reset procedure clears the modules’ EPROM memory, including all information about the Z-Wave 

network controller, calibration and power consumption data. 

1)

 

Make sure the device is connected to the power supply. 

2)

 

Pressing link key 3 times within 1.5 second (The orange LED lights up and sends out "beep" 

sound when link key is pressed.). 

3)

 

Within 1 second, press and hold the link key about 5 seconds until the LED light turns off (A 

long beep is sounded for 5 seconds and the LED light turns off). 

4)

 

IDs are excluded and all of preset value will be reset to factory default  (LED:  2-second  on, 

2-second off ; Beep sound: every 10 seconds, 0.1 seconds each ring).   

 

Installation Instructions 

It’s recommended to install the ALARM in dry indoor place. 

DEVICE INSTALLATION 

1)

 

Loosen and remove the screw at the bottom of the alarm, then  slip he alarm back cover, the 

back cover can be removed;(Fig. 1 & 2) 

2)

 

Insert 4 LR14/1.5 V alkaline batteries to the battery compartment, ensuring correct polarity is 

put (Fig.3). 

 

Fig.1                    Fig.2                        Fig.3 

Summary of Contents for CT-SMZW2008-ES

Page 1: ...settings Inclusion of this alarm on other manufacture s Wireless Controller menu allows remote turn on of connected modules when the detector is triggered After this product included into the network when the associated device such as sensor is triggered the alarm can send out alarm after receiving the wireless message The alarm is a combination of alarm and flash the alarm volume can reach 100 db...

Page 2: ... volume can reach 100 db and 90 db Specifications Radio protocol Z Wave Operation Frequency 868 42MHz 908 42 MHz SP814 2 921 42 MHz SP814 9 Power supply DC6V 600mA 1 5V LR14 x 4 Battery life 1 year RF range 25m in an open area of the wireless controller and the latest line of sight between Z Wave receiving module Alarm volume 100 db and 90 db Operation As shown below respectively alarm front side ...

Page 3: ...ssed 4 When prompt a message Request Access Success please go to the device list interface and refresh the device list the device will be displayed Z WAVE NETWORK EXCLUSION 1 Make sure the device is connected to the power supply 2 Remove the device on the APP then click finish 3 Pressing link key 3 times within 1 5 second The green LED lights up and sends out beep sound when link key is pressed 4 ...

Page 4: ...nds out beep sound when link key is pressed 3 Within 1 second press and hold the link key about 5 seconds until the LED light turns off A long beep is sounded for 5 seconds and the LED light turns off 4 IDs are excluded and all of preset value will be reset to factory default LED 2 second on 2 second off Beep sound every 10 seconds 0 1 seconds each ring Installation Instructions It s recommended t...

Page 5: ...th cable wire slot which can connect with the transformer connection wire If you use the transformer please insert the transformer coupling into the DC hole then connect the wire with wire slot Fig 4 5 Fig 4 Fig 5 3 Using the back cover as the example identified three screw holes on the wall Use the attached plastic gecko and screws fixed the back cover on the wall Fig 6 Fig 6 4 Put the alarm main...

Page 6: ...er is designed to start the alarm to notify users and deter vandals when alarm is force forcibly removed When the switch is pressed for more than 3 seconds later tamper function will start If you switch off again at this time it is equal to remove it from the wall after installation then an alarm is raised and flash and the alarm will last for 3 minutes Safety Notice Don t make the device directly...

Page 7: ...d by the detector is consistent with actual ambient illumination Do not locate the detector in shadowy place Where possible mount the detector so that the logical path of an intruder would cut across the fan pattern rather than directly towards the detector In order to obtain the best results please put the detector directly facing the entrance ...

Reviews: