User Manual of HD-TVI Speed Dome
12
Fan Parameter Configuration
You can set the
FAN CONTROL
as
TEMP
(controlled by the temperature),
ON
or
OFF
.
EIS (Electronic Image Stabilization) Configuration
You can set the
EIS FUNCTION
as
ON
or
OFF
; and set the
EIS LEVEL
as 0-3.
The selectable EIS level varies according to the different camera models.
Preset Direct Focus
You can set the preset direct focus function
ON/OF
on
PRESET DFOCUS
submenu.
Protocol and RS-485 settings
Select the protocol.
Choose the protocol on
PROTOCAL
submenu. You can configure it as
AUTO MATCH, PELCO-P,
or
PELCO-D
. When you choose
AUTO MATCH
, it is protocol self-adaptive.
Set the protocol status.
Set the
PROTOCOL STATUS
as
ON
to enable the user-defined protocol.
Enable the RS-485 configuration diagnosis.
You can set
485 CHECK
as
ON
or
AUTO
for automatic RS-485 configuration diagnosis. If the
configuration is incorrect, an alert will be received; if you set the value as
AUTO
, it will
automatically stop the diagnosis when no errors exist.
Power Memory Settings
The dome can resume its previous PTZ status after it restarted from a power-off when it stops at a
position longer than the predefined time. You can set the memory time to 10S, 30S, 60S, 180S, and
300S.
Coaxial Control
The Coaxial transmission function can be enabled to transmit the RS485 signal along with the video
signal via the BNC cable. If the connected encoding device supports the Coaxial transmission as well,
the RS485 cable will not be necessary.
Steps:
1)
Enable the Coaxial control function by setting the option of
COAXIAL CONTROL
to
ON
.
2)
Select the Coaxial control protocol, there are
HIK-C
,
PELCO-C
and
AUTO
selectable.
The transmission protocol of the connected encoding device should be set the same as the
speed dome to support the coaxial transmission.