5
5
5-3
5-3
5. Turn on the host machine's main power switch. Then set
(Level 2)COPIER>FUNCTION>SENS-ADJ>STCK-LMT in the host machine's service mode,
and press the OK key.
6. While referring to the indication, move the sensor closer to the paper, and fix it in place
where 'ON' is indicated.
Memo: If 'ON' is not indicated after moving the sensor closest to the paper, keep adding a
sheet of paper until 'ON' is indicated.
[1]
F-5-4
F-5-4
F-5-5
F-5-5
7. Perform step 6) for the other sensor.
8. Press the Stop key to end the adjustment.
1) When moving the sensor (front, rear), be sure to do so starting from where it is farthest
from the paper. This is important in respect of the characteristics of the sensor.
2) Be sure that the grounding terminal of the sensor (front, rear) is parallel to the sensor and,
moreover, its bend is in downward direction
Grounding wire terminal
F-5-6
F-5-6
Summary of Contents for Shift Tray-E1