CHAPTER 11 TROUBLESHOOTING
COPYRIGHT © 1997 CANON INC. CANON NP6330 REV.0 MAY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
11-25
3
Adjusting the Tension of the Scanner Cable
Loosen the binding screw, and align the tensioner plate to the line marked with a
scribe in advance.
Or, tighten the binding screw so that the wire spring and the hole in the side plate
shown in Figure 11-219 is 0 to 3 mm when viewed from the front.
Figure 11-219
Line drawn with a scribe
Binding screw
r
=0 – 3mm
Wire spring
Tensioner plate