CHAPTER 5 PICK-UP/FEEDING SYSTEM
COPYRIGHT © 1997 CANON INC. CANON NP6330 REV.0 MAY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
5-47
2. Removing the Pick-Up Assembly
1) Remove the cassette from the copier.
2) Remove the multifeeder inside cover and the right cover.
3) Remove the front right cover.
4) Disconnect the two connectors
q
of the lifter motor.
5) Remove the four screws
w
, and remove the cassette lifter motor assembly
e
.
Figure 5-703
6) If a pedestal is used, open the pedestal right door, remove the screw
r
and the leaf
spring
t
, and shift the registration guide
y
to the outside.
Figure 5-704
w
e
q
w
e
q
t
r
y