CHAPTER 10 TROUBLESHOOTING
COPYRIGHT © 1999 CANON INC. CANON NP6317 REV.0 APR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
10-40
9.
"E400" indication
Action
End. (Check the wiring
between the DC control-
ler and the ADF control-
ler.)
End. (Be sure to deter-
mine why CB2 went
OFF.)
Check from step 6.
Check the continuity
through the circuit bea-
ker (CB2). If it is nor-
mal, replace the 3-termi-
nal (5V) power supply.
Replace the ADF power
supply PCB.
Check the wiring from
the ADF power supply to
the ADF controller.
End.
Replace the cable be-
tween the DC controller
PCB and the ADF con-
troller PCB.
Result
Yes
Yes
Yes
Yes
No
Yes
Yes
No
Check
Does the problem disappear when the
power is switched OFF and then ON
again?
Does the problem disappear when circuit
beaker CB2 on the ADF controller PCB is
pressed?
Set the meter to the 12VDC range; then,
connect the (+) lead to J10-3 and the (-)
lead to J10-2 of the ADF controller PCB.
Is the voltage approx. 5V?
Set the meter to the 30VDC range; then,
connect the (+) lead to J9-1 and the (-)
lead to J9-2 of the ADF controller PCB. Is
the voltage approx. 24V?
Set the meter to the 30VDC range; then,
connect the (+) lead to J70-2 and the (-)
lead to J70-4. Is the voltage approx. 24V?
Does the problem disappear when the DC
controller PCB or ADF controller PCB is
replaced?
Procedure
1
2
3
4
5
6
Cause/Problem
area
Circuit
breaker (CB2)
3-terminal
(5V)
power supply
ADF
power supply
Wiring
DC controller
PCB
ADF
controller
PCB
Summary of Contents for NP6317
Page 4: ......
Page 10: ......
Page 22: ......
Page 24: ......
Page 36: ......
Page 58: ......
Page 90: ......
Page 112: ......
Page 128: ......
Page 130: ......
Page 142: ......
Page 144: ......
Page 158: ......
Page 187: ......
Page 236: ......
Page 238: ......
Page 242: ......
Page 244: ......
Page 246: ......