CHAPTER 10 TROUBLESHOOTING
COPYRIGHT © 1999 CANON INC. CANON NP6317 REV.0 APR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
10-19
3.
Lamp Brightness Adjustment (50%, 200%)
Before adjusting the lamp brightness (50%, 200%), adjust the optimum exposure in the direct
reproduction ratio (F5, w/o AE, copy density knob is centered, using the NA3 chart). Then, per-
form the adjustment below.
a.
Adjusting the Lamp Brightness (50%)
1) Make a 50% copy.
2) Check the exposure; if it is not satisfactory, perform the following:
3) Enter service mode C24.
4) Modify the value using the +/- keys (increasing the value makes the copy density lighter;
standard value is 110 to 120, variation of ten steps is equivalent to approximately one step of F
of the exposure lever on the control panel).
5) Make a 50% copy; if the copy density is not yet satisfactory, repeat steps 3) to 4).
b.
Adjusting the Lamp Brightness (200%)
1) Make a 200% copy.
2) Check the exposure; if the density is not satisfactory, perform the following:
3) Enter service mode C25.
4) Modify the value by +/- keys (increasing the value makes the copy density lighter, standard
value is 140 to 170, variation of ten steps is equivalent to approximately one step of F of the
exposure lever on the control panel).
5) Make a 200% copy; if the copy density is not yet satisfactory, repeat steps 3) to 4).
Summary of Contents for NP6317
Page 4: ......
Page 10: ......
Page 22: ......
Page 24: ......
Page 36: ......
Page 58: ......
Page 90: ......
Page 112: ......
Page 128: ......
Page 130: ......
Page 142: ......
Page 144: ......
Page 158: ......
Page 187: ......
Page 236: ......
Page 238: ......
Page 242: ......
Page 244: ......
Page 246: ......