3. The following message is displayed when backup is completed successfully.
195$0H[SRUWFRPSOHWH
4. Turn OFF the power, and remove the faulty Main Controller PCB and the Sublog Board to which data was exported.
CAUTION:
Since data cannot be migrated to a Main Controller PCB that has been used before, connect an unused Main Controller
PCB to the Sublog Board and Expansion ROM PCB where the data has been backed up (exported to) before installing it
to the machine.
A Main Controller PCB that has been connected to a machine and powered ON even once becomes a used PCB.
Restoration Procedure (Import)
1. Connect the Sublog Board with the Expansion ROM for servicing which has data exported, to an unused Main
Controller PCB.
2. Install the unused Main Controller PCB to the machine, and turn ON the power.
3. Perform the following operation to write the information saved in the Sublog Board back to the machine.
195$0LPSRUW㻈㻉
1. Press the right arrow key on the Control Panel.
2. Select [NVRAM import].
3. Press the down arrow key.
4. If the import processing completes without a problem, the data saved on the Sublog Board is deleted and the
following message is displayed.
3. Technical Explanation (System)
85
Summary of Contents for LBP351 Series
Page 1: ...Revision 4 0 LBP351 352 Series Service Manual ...
Page 12: ...Product Overview 1 Product Lineups 6 Specification 7 List of Parts 11 ...
Page 140: ...3 Remove the Main Drive Unit 1 4 Screws 2 1 2 2 2 2 4x 5 Parts Replacement and Cleaning 133 ...
Page 147: ...Adjustment 6 Actions after Replacement 141 ...
Page 149: ...Troubleshooting 7 Test Print 143 Troubleshooting 147 Obtaining Debug Log 149 ...
Page 160: ...Error Jam Alarm 8 Overview 154 Error Code Details 155 Jam Code 160 Alarm Code 163 ...
Page 171: ...Service Mode 9 Overview 165 Service Mode 169 ...