![Canon iX7000 Series Service Manual Download Page 48](http://html.mh-extra.com/html/canon/ix7000-series/ix7000-series_service-manual_2553136048.webp)
(4) Ink absorber counter setting
Set the ink absorber counter value to a new EEPROM after the logic board is replaced in servicing.
1) Before replacement of the logic board, check the ink absorber counter value in EEPROM information
print.
2) After replacement of the logic board, the ink absorber counter value should be set in the service mode
using the Service Tool.
In the
Ink Absorber Counter
section of the Service Tool, select
Main
from the
Absorber
pull-down
menu.
From the
Counter Value(%)
pull-down menu, select the value (in 10% increments) which is the closest
to the actual counter value confirmed before replacement of the logic board, and click
Set
.
3) Print EEPROM information to confirm that the value is properly set to the EEPROM.
(5) Wetting liquid counter setting
Set the wetting liquid counter value to a new EEPROM after the blade cleaner unit or logic board is replaced
in servicing.
<When the blade cleaner unit is replaced>
1) After replacement of the blade cleaner unit, the wetting liquid counter value should be reset in the service
mode using the Service Tool.
In the
Wetting Liquid Counter
section of the Service Tool, select
0
(zero) from the
Counter Value(%)
pull-down menu, and click
Set
.
2) Print EEPROM information to confirm that the value is set to "0.00" (W = 0.00).
<When the logic board is replaced>
1) Before replacement of the logic board, check the wetting liquid counter value (W = ###) in EEPROM
information print.
2) After replacement of the logic board, the wetting liquid counter value should be set in the service mode
using the Service Tool.
In the
Wetting Liquid Counter
section of the Service Tool, from the
Counter Value(%)
pull-down
menu, select the value (in 10% increments) which is the closest to the actual counter value confirmed
before replacement of the logic board, and click
Set
.
3) Print EEPROM information to confirm that the value (W = ###) is properly set to the EEPROM.
<4-1. User Mode & 4-2. Service Mode>
45 / 53
Summary of Contents for iX7000 Series
Page 9: ...Click on the image to enlarge it 6 53 ...
Page 10: ...7 53 ...
Page 37: ...8 Remove the ASF unit 5 screws 34 53 ...
Page 50: ...47 53 ...
Page 54: ... 2 Service test print Service test print sample Print on A3 or LDR sized paper 51 53 ...
Page 55: ... 3 Ink absorber counter value print Print sample 4 5 Verification Items 52 53 ...