4
4-48
Frequency Test
A press on '2' on the keypad from the MODEM test menu selects the frequency test.
In this test, signals of the following frequencies from the modem are transmitted using the
telephone line terminal and the speaker. To select a different frequency,
Keypad
Frequency
1
462Hz
2
1100Hz
3
1300Hz
4
1500Hz
5
1650Hz
6
1850Hz
7
2100Hz
MEMO:
The frequency and the output level of individual frequencies are in keeping with the
output level set in service mode.
G3 Signal Transmission Test
A press on '4' on the keypad from the MODEM test menu selects the G3 signal transmission
test. In this test, the following G3 signals from the modem are transmitted using the telephone
line terminal and the speaker. To select a different transmission speed, use the keypad.
Keypad
Transmission speed
0
300bps
1
2400bps
2
4800bps
3
7200bps
4
9600bps
5
TC7200bps
6
TC9600bps
7
12000bps
8
14400bps
MEMO:
The output level of individual signals is in keeping with the setting made in service
mode.
A press on '5' on the MODEM test menu selects the DTMF signal transmission test. In the
test, the following DTMF signals from the modem are transmitted using the telephone line
terminal and the speaker. The number pressed on the keypad selects a specific DTMF signal.
T-4-61
T-4-61
T-4-62
T-4-62
MEMO:
The output level of individual signals is in keeping with the setting made in service
mode.
Tonal/DTMF Signal Reception Test
A press on '6' on the keypad from the MODEM test menu selects the tonal signal/DTMF signal
reception 0 test. In this signal, the tonal signal/DTMF signal received from the telephone line
terminal can be checked to find out if it was detected by the modem.
MODEM TEST
OFF OFF OFF
OFF OFF OFF
changes from '0' to '1' in response to detection of a signal of 462±25Hz.
changes from '0' to '1' in response to detection of a signal of 1100±30Hz.
changes from '0' to '1' in response to detection of a signal of 2100±25Hz.
Tonal signal reception test
MODEM TEST
OFF OFF OFF 5
DTMF signal reception test
The received DTMF signals are indicated starting
from the right using the 2nd character of the display.
V.34 G3 Signal Transmission Test
A press on '8' on the keypad from the MODEM test menu selectes the V.34 G3 signal
transmission test. The V.34 G3 signals below are sent from the modem using the modular
jack and the speaker by pressing the start key. The Baud rate can be changed with the
keypad, and the Speed can be changed with the left/right arrow key.
Keypad
Baud rate
0
3429baud
1
3200baud
2
3000baud
3
2800baud
4
2743baud
5
2400baud
F-4-14
F-4-14
T-4-63
T-4-63
Summary of Contents for IMAGERUNNER 2530
Page 9: ...1 1 Periodical Service Consumable Parts and Cleaning Parts ...
Page 13: ...1 5 1 Cleaning Parts Fixing guide Transfer guide F 1 2 F 1 2 ...
Page 14: ...2 2 Adjustment Overview Adjustment when replacing parts image position adjustment ...
Page 20: ...3 3 Error Code Overview Error Code Jam Code Alarm Code ...
Page 34: ...4 4 Service Mode Overview Details of Service Mode ...
Page 85: ...5 5 Parts Replacement and Cleaning List of Parts ...
Page 98: ...6 6 Product Overview Specifications Product lineups Basic Configuration ...
Page 106: ...7 7 Version Upgrading Upgrading Targets and Procedure ...