4-5
4
SSSW-SW03
List of Functions
Bit
Function
1
0
0
TCF criteria
Loose
Normal
1
Echo protect tone for high-speed transmission Transmitted
Not transmitted
2
not used
-
-
3
not used
-
-
4
not used
-
-
5
not used
-
-
6
not used
-
-
7
Tonal signal before CED signal transmission
Transmitted
Not transmitted
Detailed Discussions of Bit 0
Select whether to make the TCF criteria loose when the system with a V.34 modem receives
an image using the V.17 protocol.
When "Loose" is selected, fallback hardly occurs when an image is received using the V.17
protocol.
However, since the transmission speed is fast, erroneous lines can be generated after start
of image reception or the communication time can become long due to retransmission of
erroneous frames.
Detailed Discussions of Bit 1
Selects whether or not the echo protect tone is transmitted for high-speed transmission
(9600 or 7200 bps).
If errors due to line conditions occur frequently during fax transmission, select “Transmitted”.
When “Transmitted” is selected, a non-modulated carrier is transmitted as a synchronization
signal before the image transmission.
MEMO:
Codes for errors that can occur during transmission because of line conditions:
##100, ##104, ##281, ##282, ##283, ##750, ##755, ##760,##765
Detailed Discussions of Bit 7
Use it to enable/disable transmission of a 1080-Hz tonal signal before transmission of the
CED signal.
Select 'transmit' if errors occur frequently because of an echo when reception is from
overseas.
●
T-4-4
T-4-4
MEMO:
Any of the following error code may be indicated because of an echo at time of
reception
##0005, ##0101, ##0106, ##0107, ##0114, ##0200, ##0201, ##0790
SSSW-SW04
List of Functions
Bit
Function
1
0
0
not used
-
-
1
Check CI frequency
Yes
No
2
the number of final flag sequences of protocol signals
2
1
3
Reception mode after CFR signal transmission
high speed
high speed/low
speed
4
the length of the period of ignoring low speed signals
after CFR output
1500ms
700ms
5
Frequency of CI signal is checked when PBX is set.
Yes
No
6
CNG signal for manual transmission
Not transmitted Transmitted
7
CED signal for manual reception
Not transmitted Transmitted
Detailed Discussions of Bit 1
In automatic recieving, CI frequency check can be selected. If ‘Yes’ is selected, the upper and
lower limits of the CI frequency are checked, and automatic recieving can only go ahead if
both values meet German regulations.
Detailed Discussions of Bit 2
Use it to select the number of last flag sequences for a protocol signal (transmission speed at
300 bps). Select '2' if the other party fails to receive the protocol signal properly.
MEMO:
Any of the following error codes may be indicated at time of transmission
##0100, ##0280, ##0281, ##0750, ##0753, ##0754, ##0755, ##0758, ##0759, ##0760,
##0763 ##0764, ##0765, ##0768, ##0769,##0770, ##0773, ##0775, ##0778,
##0780, ##0783, ##0785, ##0788
Detailed Discussions of Bit 3
Use it to select an appropriate reception mode after transmission of the CFR signal.
If errors occur frequently at time of reception because of the condition of the line, select 'high
speed' for reception mode and, at the same time, selects 'do not receive' for 'ECM reception.'
●
T-4-5
T-4-5
Summary of Contents for IMAGERUNNER 2530
Page 9: ...1 1 Periodical Service Consumable Parts and Cleaning Parts ...
Page 13: ...1 5 1 Cleaning Parts Fixing guide Transfer guide F 1 2 F 1 2 ...
Page 14: ...2 2 Adjustment Overview Adjustment when replacing parts image position adjustment ...
Page 20: ...3 3 Error Code Overview Error Code Jam Code Alarm Code ...
Page 34: ...4 4 Service Mode Overview Details of Service Mode ...
Page 85: ...5 5 Parts Replacement and Cleaning List of Parts ...
Page 98: ...6 6 Product Overview Specifications Product lineups Basic Configuration ...
Page 106: ...7 7 Version Upgrading Upgrading Targets and Procedure ...