9
startup control is under way, the reading of
the main thermistor is less than 150 deg C
continuously for 400 msec 1.3 sec after it
has indicated 140 deg C.
E003-
0000
The fixing temperature is too low after a
standby state.
While regular temperature control is under
way, the reading of the main thermistor is
less than 140 deg C continuously for 400
msec or more.
Reset the condition in service mode:
COPIER>FUNCTION>CLEAR> ERR.
Replace the main thermistor. Replace the
DC controller PCB.
E007-
0000
The rotation of the fixing film is faulty.
While the fixing motor is rotating, the marker
signal is not detected for 6 sec with the
reading of the main thermistor indicating 100
deg C or more.
Reset the condition in service mode:
COPIER>FUNCTION>CLEAR> ERR.
Replace the main thermistor. Replace the
DC controller PCB.
E010-
0001
The rotation of the main motor is faulty.
Detection is executed every 100 msec after
the start of motor rotation; however, the drive
detection signal is absent for 2 sec.
Replace the main motor. Replace the DC
controller PCB.
E010-
0002
The rotation of the main motor is faulty.
During motor rotation, detection is executed
every 100 msec; however, the drive signal is
absent 5 times in sequence.
Replace the main motor. Replace the DC
controller PCB.
E014-
0001
The rotation of the fixing motor is faulty.
Detection is executed every 100 msec after
the start of motor rotation; however, the drive
detection signal is absent for 2 sec
Replace the fixing motor. Replace the DC
controller PCB.
E014-
0002
The rotation of the fixing motor is faulty.
During motor rotation, detection is executed
every 100 msec; however, the drive signal is
absent 5 times in sequence.
Replace the fixing motor. Replace the DC
controller PCB.
E019-
0000
The waste toner case is full, or the waste
toner case full sensor is faulty
When the waste toner case is identified as
being full for 2000 prints continuously, an
alert is issued; thereafter, the case is
identified as being full continuously for 100
prints
Replace the waste toner sensor. Replace
the DC controller PCB.
E020-
0000
The path between the sub hopper and the
developing assembly is clogged with toner.
The developing assembly toner sensor
detects the absence of toner, while the sub
hopper toner sensor detects the presence of
toner. With the developing clutch turned on,
the hopper feedscrew motor is rotated for 1
sec intermittently 194 times; still, the
Replace the developing assembly toner
sensor. Replace the sub hopper toner
sensor. Replace the DC control PCB.