8
E805-
0000
Fan failure
The fan is faulty.
- Check the fan connector. - Replace the
fan. - Replace the DC controller PCB.
E808-
0000
Fixing drive circuit failure
- The heater does not turn on. - A fixing drive
motor failure was detected.
- Check the connector of the fixing film
unit. - Replace the fixing film unit. -
Replace the fixing drive motor. - Replace
the DC controller PCB. - Replace the
power supply PCB.
Canon iR3035 Trouble Error Codes
Code
Description
Remedy
E000-
0001
The temperature of the fixing assembly is
abnormally high.
While startup control is under way, the
reading of the main thermistor is less than
30 deg C continuously for 200 msec or more
1 sec after the start of power supply. While
startup control is under way, the reading of
the main thermistor is less than 70 deg C
continuously for 200 msec or more 2 sec
after the start of power supply. While startup
control is under way, the reading of the main
thermistor is less than 120 deg C
continuously for 200 msec 6 sec after the
start of power supply. The startup control
does not end 30 sec after the start of power
supply.
Reset the condition in service mode:
COPIER>FUNCTION>CLEAR> ERR.
Replace the main thermistor. Replace the
DC controller PCB.
E001-
0000
The temperature of the fixing assembly is
abnormally high.
The reading of the main thermistor is 250
deg C or more continuously for 200 msec.
Reset the condition in service mode:
COPIER>FUNCTION>CLEAR> ERR.
Replace the main thermistor. Replace the
DC controller PCB.
E001-
0001
The temperature of the fixing assembly is
abnormally high.
The hardware circuit detects overheating of
the main or sub thermistor for 200 msec.
Reset the condition in service mode:
COPIER>FUNCTION>CLEAR> ERR.
Replace the DC controller PCB.
E001-
0002
The temperature of the fixing assembly is
abnormally high.
The reading of the sub thermistor is 295 deg
C or more continuously for 200 msec.
Reset the condition in service mode:
COPIER>FUNCTION>CLEAR> ERR.
Replace the sub thermistor. Replace the
DC controller PCB.
E002-
0000
The rise in temperature of the fixing
assembly is faulty
While startup control is under way, the
reading of the main thermistor is less than
115 deg C continuously for 400 msec 1.3
sec after it has indicated 100 deg C. While
Reset the condition in service mode:
COPIER>FUNCTION>CLEAR> ERR.
Replace the main thermistor. Replace the
DC controller PCB.