Chapter 5
5-3
5.4 Controlling the Laser Scanner Motor
5.4.1 Overview
0014-4989
i-SENSYS MF4150 / i-SENSYS MF4140 / i-SENSYS MF4120 /
This is the control to rotate the scanner motor at constant speed.
The scanner motor is the 3-phase DC brush-less motor with hall element included, and is combined with the drive circuit.
The following chart shows the control circuit for the scanner motor.
F-5-3
5.4.2 Scanner Motor Speed Control
0014-4990
i-SENSYS MF4150 / i-SENSYS MF4140 / i-SENSYS MF4120 /
This is the control to rotate the scanner motor at constant speed.
The following is the procedure of this control.
1) At activating the scanner motor, CPU outputs /ACC signal to the scanner driver IC to accelerate the scanner motor forcedly. The scanner motor will start rotating.
2) CPU periodically turns on the laser, and compares /BDI signal and the cycle of the reference clock to detect the rotation of the scanner motor.
3) When the rotation of the scanner motor exceeds the specified value, CPU outputs /DEC signal to decelerate the scanner motor. CPU controls /ACC or /DEC
signal to control the rotation of the scanner motor until it becomes its specified value.
5.4.3 Detection of Fault of the Scanner Motor
0014-4991
i-SENSYS MF4150 / i-SENSYS MF4140 / i-SENSYS MF4120 /
CPU of the DCNT board monitors the frequency comparator to judge if the scanner motor rotates at the specified rotation frequency.
When the following statuses occur, CPU judges that there is a fault or error and stops the engine. At the same time, it notices the details of the error to the SCNT
board.
1) Scanner fault
If /BDI signal cannot be detected 1.5 sec after completing forced acceleration of the scanner motor, extend the detection time by 120sec. If the specified cycle of /
BDI signal cannot be detected, it should be judged as scanner fault.
2) BD fault
If /BDI signal cannot be detected in 100msec after forced acceleration of the scanner motor or the specified cycle of /BDI signal cannot be detected for 2 sec or
more after the scanner motor reached its specified rotation, it should be judged as BD fault.
3) BD error
If /BDI signal cannot be detected at the specified cycle while CPU outputs /BD signal to the SCNT board, it should be judged as BD error.
If door open is detected in 200msec after BD error was detected, CPU does not transmit BD error to the SCNT board.
DCNT board
M
J931-9
X902
IC902
CPU
J932-4
J932-3
J932-2
J932-1
J902-1
J904-1
J904-2
J904-3
J904-4
/ACC
/DEC
/BDI
BD sensor
Divider
Reference
clock
Frequency
comparator
Laser / scanner block
Integration
circuit
Scanner driver IC
Scanner motor
Drive
circuit
+24V
+24V
Summary of Contents for imageCLASS MF4100 Series
Page 1: ...Aug 21 2006 Service Manual MF4100 Series...
Page 2: ......
Page 6: ......
Page 12: ...Contents...
Page 13: ...Chapter 1 Introduction...
Page 14: ......
Page 16: ......
Page 29: ...Chapter 2 Basic Operation...
Page 30: ......
Page 32: ......
Page 34: ......
Page 35: ...Chapter 3 Original Exposure System...
Page 36: ......
Page 38: ......
Page 42: ...Chapter 3 3 4 F 3 15...
Page 43: ...Chapter 4 Original Feeding System...
Page 44: ......
Page 46: ......
Page 51: ...Chapter 4 4 5 F 4 18...
Page 52: ......
Page 53: ...Chapter 5 Laser Exposure...
Page 54: ......
Page 56: ......
Page 61: ...Chapter 6 Image Formation...
Page 62: ......
Page 64: ......
Page 68: ......
Page 69: ...Chapter 7 Pickup and Feed System...
Page 70: ......
Page 72: ......
Page 79: ...Chapter 8 Fixing System...
Page 80: ......
Page 82: ......
Page 89: ...Chapter 9 External and Controls...
Page 90: ......
Page 92: ......
Page 99: ...Chapter 10 Maintenance and Inspection...
Page 100: ......
Page 102: ......
Page 105: ...Chapter 11 Measurement and Adjustments...
Page 106: ......
Page 108: ......
Page 111: ...Chapter 12 Error Code...
Page 112: ......
Page 113: ...Contents Contents 12 1 Error Code 12 1 12 1 1 Error Code Outline 12 1 12 1 2 Error Code 12 1...
Page 114: ......
Page 118: ......
Page 119: ...Chapter 13 Service Mode...
Page 120: ......
Page 122: ......
Page 133: ...Chapter 14 Service Tools...
Page 134: ......
Page 135: ...Contents Contents 14 1 Service Tools 14 1 14 1 1 Solvents Lubricants Table 14 1...
Page 136: ......
Page 138: ......
Page 139: ...Aug 21 2006...
Page 140: ......