Chapter 12
12-2
0041
Can't receive carrier within 6 sec. after sending PPR.
0042
Can't receive correct signal after sending RNR signal
0043
Receive incorrect signal at phase D in ECM mode.
0044
Can't receive carrier/FSK signal within 6 sec. After sending MCF. ln ECM mode.
0047
Can't receive correct signal or DCN received after sending ERR signal.
0048
Can't receive correct signal after receive PPS_PRI_Q
004B
Can't detect correct FSK signal even through detected FSK tone within 6 sec.
004C
Handshake fail during re-train or between page in V34 Rx.
004E
Receive DCN signal after sending DIS in V.34.
004F
Remote side disconnected after sending ANSam in V.8 phase.
0050
Can't receive any correct signal after detected CJ signal in V.8 phase.
0051
Can't receive phase 3 signal after phase 2 within 20 seconds in V.34.
0053
Modem disconnect after phase 4 in V.34.
0054
Remote side disconnect after phase 4 in V.8
0055
Receive incorrect signal after sending DIS signal in V.34
0056
Modem disconnect after sending CFR in V.34
0058
Can't detect image signal within 6 sec after modem enter to primary phase in V.34
005A
Modem cannot detect any correct ECM frame with 3 minutes in phase C.
005B
Modem can't detect control channel with 12 sec in phase C
005C
Detect busy tone within control channel after phase C.
005D
Modem can't detect any correct ECM frame with 12 sec in phase C.
005E
Can't detect control channel signal after received RCP frame within 6 sec
005F
Can't detect silence after sending JM signal for polling TX function.
0060
There are no any bullietin files to be polled in V.34.
0061
Machine cannot detect V.21 or V.8 signal with 35 sec.
0062
Modem disconnect in phase D after our side sending out flags sequence in control channel.
0063
Can't receive any flag sequence in control channel within 25 sec in phase D.
0064
Can't detect any control channel signal in phase D within 60 sec even through energy still on the line.
0065
Can't detect any control channel signal within 60 sec after detect sillence in phase D.
0066
Can't receive T.30 signal or carrier after sending CFR in V.34.
0069
Capability no match paper size after received is DCS signal.
0070
User press stop key within receiving.
0071
Memory full within receiving.
0080
Can't detect any G3 signal within 35 sec. specified by ITU-T in phase B.
0081
Received DTC signal in transmission phase.
0082
Transmitting unit receives a signal other than DIS or DTC. And DCN in phase B.
0083
Detected FSK signal, but Can't receive any signal within 35 sec.
0084
Detect DCN signal in phase B.
0085
Transmitting unit sending DCS 3 times consecutively, but each time responds with DIS/DTC
0086
Detected responds signal other than DTC,DIS,FTT,DCN or CFR after sending DCS.
0087
Training attempt has failed because speed unit can't adjust to low lower speed.
0088
Received DCN signal after sending out DCS signal
008B
Receivers protcol of DIS is received, but it is not compatible with our machine.
008C
Remote side or our side not support capability.
008D
Receivers protocol of DIS is received, but remote side can't receive document temporary, may because by run out of paper or other reason.
008F
Modem not ready to received V.34 data within 6 sec after received CFR signal.
0090
Called side document not ready for our polling.
0091
Can't receive any commabd after send DCN signal 3 times consecutively
0093
Received DCN signal after sending out DCN signal
0094
Time out during transmit ECM frame or RCP command.
0095
Wrong ID number
0096
SUBADDRESS/PASSWORD capability not match in polling Rx mode.
009A
Can't detect any signal after sending CI signal.
009D
Remote side hang up before V.34 modem enter phase 2 state in V.34 polling Rx.
009E
Manual Tx over 15 minutes whin in phase C by non-ECM mode.
00A0
User stop or cancel transmission job.
00A1
Document JAM within transmission
00AE
Can't finished V.8 procedure or detect V.21 signal after CM signal
00AF
Modem can't enter into control channel after TX side sending out RCP signal
for V34
00B1
Can't finish V.8 procedure or detect V.21 signal after ANSam signal within 35 sec.
00B2
Can't detect phase 2 signal after our side sending CJ signal within 30 sec
00B3
Can't detect correct V.21 or JM signal after sending CM or CJ signal.
00B4
Can't detect correct phase 2 signal within 25 second after CM/JM signal exchange.
00B5
Can't detect phase 3 signal after Phase 2
00B6
Can't detect phase 4 signal within 25 sec after CM/JM exchange.
Error Code
Description
Summary of Contents for imageCLASS MF4100 Series
Page 1: ...Aug 21 2006 Service Manual MF4100 Series...
Page 2: ......
Page 6: ......
Page 12: ...Contents...
Page 13: ...Chapter 1 Introduction...
Page 14: ......
Page 16: ......
Page 29: ...Chapter 2 Basic Operation...
Page 30: ......
Page 32: ......
Page 34: ......
Page 35: ...Chapter 3 Original Exposure System...
Page 36: ......
Page 38: ......
Page 42: ...Chapter 3 3 4 F 3 15...
Page 43: ...Chapter 4 Original Feeding System...
Page 44: ......
Page 46: ......
Page 51: ...Chapter 4 4 5 F 4 18...
Page 52: ......
Page 53: ...Chapter 5 Laser Exposure...
Page 54: ......
Page 56: ......
Page 61: ...Chapter 6 Image Formation...
Page 62: ......
Page 64: ......
Page 68: ......
Page 69: ...Chapter 7 Pickup and Feed System...
Page 70: ......
Page 72: ......
Page 79: ...Chapter 8 Fixing System...
Page 80: ......
Page 82: ......
Page 89: ...Chapter 9 External and Controls...
Page 90: ......
Page 92: ......
Page 99: ...Chapter 10 Maintenance and Inspection...
Page 100: ......
Page 102: ......
Page 105: ...Chapter 11 Measurement and Adjustments...
Page 106: ......
Page 108: ......
Page 111: ...Chapter 12 Error Code...
Page 112: ......
Page 113: ...Contents Contents 12 1 Error Code 12 1 12 1 1 Error Code Outline 12 1 12 1 2 Error Code 12 1...
Page 114: ......
Page 118: ......
Page 119: ...Chapter 13 Service Mode...
Page 120: ......
Page 122: ......
Page 133: ...Chapter 14 Service Tools...
Page 134: ......
Page 135: ...Contents Contents 14 1 Service Tools 14 1 14 1 1 Solvents Lubricants Table 14 1...
Page 136: ......
Page 138: ......
Page 139: ...Aug 21 2006...
Page 140: ......