Clean UV LED Unit Quartz Window
Introduction
Dust and other debris as well as ink mist can accumulate on the UV LED unit windows. There is a
quartz window below each of the two sets of UV LED units.
When to do
Inspect and clean the UV LED unit windows once a month.
Equipment
• Gloves (for example: Ansell Microflex 93-260)
• Cloth-Poly Wipe 10cm x 10cm (lint-free)
• Isopropyl alcohol - IPA (>= 98%)
• Scraper or razor blade
Procedure
1.
Wipe the bottom of the quartz window with a lint-free cloth soaked in isopropyl alcohol.
2.
If you see any cured ink, it can be removed by scraping with a razor blade or similar tool held at a
45-degree angle, afterwards wipe with a lint-free cloth soaked in isopropyl alcohol.
Clean UV LED Unit Quartz Window
200
Chapter 9 - Printer Maintenance
Summary of Contents for Arizona 2300 Series
Page 1: ...Arizona 2300 series Operation guide 2020 2022 Canon Production Printing ...
Page 8: ...Contents 8 ...
Page 9: ...Chapter 1 Introduction ...
Page 15: ...Chapter 2 Safety Information ...
Page 38: ...Roll Media Safety Awareness 38 Chapter 2 Safety Information ...
Page 39: ...Chapter 3 Navigate the User Interface ...
Page 63: ...Chapter 4 Operate the Printer ...
Page 91: ...Chapter 5 Roll Media Option ...
Page 119: ...Chapter 6 Static Suppression Option ...
Page 123: ...Chapter 7 Manage a White Ink Workflow ...
Page 167: ...Chapter 8 Ink System Management ...
Page 172: ...Change Ink Bags 172 Chapter 8 Ink System Management ...
Page 173: ...Chapter 9 Printer Maintenance ...
Page 217: ...Chapter 10 Troubleshooting ...
Page 228: ...Install software updates without Remote Service 228 Chapter 10 Troubleshooting ...
Page 229: ...Chapter 11 Regulation Notices ...
Page 236: ...CE Declaration of Conformity EEA including Switzerland 236 Chapter 11 Regulation Notices ...
Page 238: ...238 Chapter 11 Regulation Notices ...
Page 239: ...Appendix A Application Information ...
Page 243: ......