Requirement:
Check
When / Action
Grounded Electrical Circuit
• Requires an insulated equipment grounding conduc-
tor running with the supply conductors
• Electrical connection complies to above Product Safe-
ty Data Sheet
• 2x Power cord complying to printer and local stand-
ards to be supplied by customer
For location of power, data and compressed air con-
nections at the printer please refer to figures in Oper-
ating Space requirements
.
Facility air
• Connection to facility air supply via 12mm/ 0,5” OD
tubing, or adapter
• Peak flow: 113 l/min (4 cfm) at 690 kPa (100 psi) – dry
air (provided via coalescing filter)
.
Select the correct low or high voltage vacuum pump
200-220
Vac
220-240
Vac
Proximity to Solvent Printers
• We strongly recommend that solvent -based printers
be kept in a separate room from UV ink printers.
.
Onyx RIP
• Requirement: ONYX® Thrive™ 19 or higher
• In case of use of Arizona Xpert, then a recent version
of Chrome must be installed on the RIP station
.
Web Browser(s) for the User Interface
• Internet Explorer 11 or higher
• Edge
• Firefox
• Chrome
NOTE
Always use a recent version.
.
On Remote Service
(ISO/IEC 27001 certified)
• Standard installation is ORS enabled
The communication connections used are 100% se-
cure, all communicated data being encrypted accord-
ing to the HTTPS industry standard or via a secured
and dedicated VPN tunnel – the global standard for
sensitive transactions in corporate information sys-
tems.
• For detailed information about ORS please refer to the
ORS product sheet
.
preferred hostname.
Customer Contact person
ORS connection
Customers initials
Site Preparation Pre-Installation Che Sign off
Chapter 7 - Site Preparation checklists
45
Summary of Contents for Arizona 1300
Page 1: ...Arizona 1300 Technical guide Site preparation guide 2021 Canon Production Printing...
Page 2: ...Edition 2021 06 US...
Page 4: ...Contents 4...
Page 5: ...Chapter 1 Introduction...
Page 11: ...Chapter 2 Product Description and Safety Information...
Page 16: ...UV Light Safety 16 Chapter 2 Product Description and Safety Information...
Page 17: ...Chapter 3 Shipping Handling...
Page 25: ...Chapter 4 Specifications and Requirements...
Page 38: ...Customer Network Requirements 38 Chapter 4 Specifications and Requirements...
Page 39: ...Chapter 5 Operator Training...
Page 41: ...Chapter 6 Product Safety Data Sheet...
Page 43: ...Chapter 7 Site Preparation checklists...
Page 48: ...On Remote Service Connectivity Information 48 Chapter 7 Site Preparation checklists...
Page 49: ......