background image

4

Please read this manual before installing and using the heater.

What to do if you smell gas

1.  Turn OFF the main gas supply.

2.  Extinguish any open flame.

3. Open windows.

4. Do not touch electrical switches.

5. Do not use your telephone.

6. Call your gas supplier immediately from a neighbour’s phone.

Warnings

1. Improper installation, adjustment, alteration, service or maintenance

can cause injury or property damage.  Refer to other sections of this

manual for correct procedures, or consult with place of purchase, a

licensed plumber, a gas supplier or the CANNON distributor listed in

this manual.

2. Do not build the heater into bookcases or walls. Install only as referred

to in these installation instructions.

3. Due to high temperatures the room heater should be located out of

traffic and away from:

Furniture and draperies,

Combustible materials,

Gasoline and other flammable liquids,

Do not place clothing or other flammable material on or near the heater.

4. Keep curtains*, clothing, furniture and other flammable materials at

least 900mm from front, rear and sides of the heater.

* At the owner’s discretion curtain clearance can be less than 900mm

as long as they are restrained from the front, top and sides of the heater.

The manufacturer takes no responsibility if  curtain clearance is less than

900mm and not restrained.

5. Children and adults should be alerted to the hazard of high surface

temperature and should take care to avoid burns or clothing ignition.

This appliance is not intended for use by persons (including chil-

dren) with reduced physical, sensory or mental capabilities, or lack

of experience and knowledge, unless they have been given super-

vision or instruction concerning use of the appliance by a person

responsible for their safety.
Children should be supervised to ensure that they do not play with

the appliance.

6. Never attempt to burn paper or any other material in the heater.

7.   Do not place articles on or against this appliance.

Do not use or store flammable materials near this appliance.

Safety warnings

21

To check the operation of the electronic (module) controller (Type 537 ABC) you will require a digital

multimeter with the functions to measure AC/DC voltage, continuity, resistance and micro-amps.

It is critical that the appliance is earthed and that the active and neutrals are not reversed.

Item No

Check

Action

1.

No ignition when appliance

• Check 240 volts power to heater in incoming plug

is turned on.

connector.

2.

Power present but appliance

• If there is power to the brown wire in the 8 way

not operating.

switch connector the module may be in lockout

mode. To reset the module turn off the power supply

for 10 seconds and then turn the power on again.

3.

After resetting the module

• Check the internal 2-A fuse in the loom.

and appliance is still not

operating.

4.

If the fuse is O.K. and still

• Check other connections are in place.

appliance not operating

• If the last checks are correct the ignition electrode

should spark at the same time as the gas control

solenoid valves open. At this point the spark

electrode will activate for up to 10 seconds maxi

mum until the flame has been established. Terminal

14 (white wire into the 8 way switch connector)

will be energised as soon as the flame has been

sensed.

5.

Confirm spark is produced

• A blue spark can be seen when the heater ignition

when heater is turned on.

process starts. Ensure spark is present between

electrode and burner.

6.

If no spark being produced

• 

 

Check that spark lead is connected into module.

• 

 

Check the continuity of the HT cable.

• 

 

Check that there is no short circuit to earth and

spark gap is correct. (Refer figure 28). A positive

check is to use a jumper wire and connect one end

of the earth and hold the other end with insulated

pliers 4mm from the spark generator on the module.

If there is no spark to earth then change the module.

7.

Spark is being produced

• Listen for cracking sound. The spark is misdirected.

but not at burner.

Check the spark ceramic insulator for signs of

cracks.

8.

Sparks, ignites on low flame

• Check that the wall socket to the appliance has

then extinguishes after 10

correct polarity. Do not use an extension cord. Check

seconds. Continues to spark

polarity in the electrical supply lead to appliance.

during flame presence.

• Check that the sense electrode is in the flame.

• Check that appliance is earthed correctly. A check

between the earth pin on the plug and an unpainted

part of the appliance should see a resistance of

0.1 ohms.

Trouble-shooting. (Do not modify this appliance).

Summary of Contents for FITZFS-SDSEB-NG

Page 1: ...proved for use with Natural and Propane gases Please leave instructions with the owner FITZROY FREESTANDING USER INSTRUCTIONS INSTALLATION INSTRUCTIONS SERVICE INSTRUCTIONS FREESTANDING MODELS FITZFS...

Page 2: ...g installation Gas control Gas pressure point Installation tips Flue installation 16 17 Flue kit Service instructions 18 20 General To replace primary glass To replace outer glass To replace the gas c...

Page 3: ...ith manufacturer s instruc tions this warranty may be void The customer must keep their Tax Invoice as proof of purchase of this product and compliance certificate as proof of required installation Mo...

Page 4: ...ammable material on or near the heater 4 Keep curtains clothing furniture and other flammable materials at least 900mm from front rear and sides of the heater At the owner s discretion curtain clearan...

Page 5: ...Testing the effectiveness of the flue Before testing the flue confirm air vents are unobstructed If an exhaust fan or other heating appliances are present switch them on This is to test that there is...

Page 6: ...ol lay out refer to figure 2 3 To turn heater on press switch to POWER ON position There is a 5 second delay before the burner ignites At this setting the burner is on LOW and the fan speed is on LOW...

Page 7: ...switch for LOW setting Refer figure 7 On low burner setting it is more efficient to operate the fan speed on LOW 8 If the burner fails to ignite wait 20 seconds and repeat the ignition procedure See...

Page 8: ...heater fitted with the glass front All cleaning should be carried out when the heater is cold Clean the outer glass with a liquid solution such as Windex or similar Do not use harsh abrasive cleaners...

Page 9: ...essure 1 13 kPa Nat Gas 2 75 kPa Propane Fan 3 speed Controller Electronic direct spark Power requirement 240 VAC 10 Amp Power consumption 90 VA maximum Optional Accessories Silver trim Cathedral ceil...

Page 10: ...d furnishing refer to warning 3 4 on page 4 For minimum clearances refer fig 9 and 10 4 Remove the carton from the heater and lift from pallet Check that the heater is suitable for the gas available R...

Page 11: ...e either side Refer figure 12 10 Remove the heater front by pulling it towards you gently to partly disengage it from the body of the heater then gently lift it up vertically to completely disengage i...

Page 12: ...ront log No 4 Right back log Position the four individually numbered logs in the following order on the burner head as shown in figures 17 20 The male locating pins in the burner head must engage with...

Page 13: ...rope Check that the gas pressure is correctly adjusted If the heater still does not operate to specification refer to the trouble shooting chart on pages 20 21 or contact Sampford IXL in your state P...

Page 14: ...clockwise to decrease pressure 20 Switch the heat button back to Low Flame position as indicated in figure 25 a retain spanner in position and using a screwdriver as per figure 25 b adjust the central...

Page 15: ...service agents please refer page 19 Installation tips Make sure that the heater is fully commissioned and be certain to con duct a test of the integrity of the flue operation taking into account any...

Page 16: ...s have been observed For clearances refer page 10 2 The centre line of the flue is 115mm to rear of appliance including rear spacers 3 Carry out installation as per figure 26 ceiling plate installatio...

Page 17: ...17 27...

Page 18: ...tion instructions 2 The blue module ignition device needs to be removed to allow re moval of the gas control Remove LH screw from front lower section of ignition device Remove screw from front of rect...

Page 19: ...rgise dependant on room temperature The burner should now operate on high setting To replace the fan pressure switch 1 Remove the lower pedestal front by unscrewing four M3 screws Refer page 11 figure...

Page 20: ...e to this appliance For service to this appliance or spare parts contact the CANNON distributor Sampford IXL 52 70 Sparks Avenue Fairfield Vic 3078 Phone 1300 727 421 Fax 1300 727 425 email service sa...

Page 21: ...way switch connector will be energised as soon as the flame has been sensed 5 Confirm spark is produced A blue spark can be seen when the heater ignition when heater is turned on process starts Ensure...

Page 22: ...than 1 5 micro amps at all times Take precaution because the ionisation probe can have a high negative voltage and can cause shock 11 Fuse blowing If the fuse continues to blow check the solenoid coi...

Page 23: ...23...

Page 24: ...INS S F F F Part No F2904 Revision D 2009 Cannon FITZROY FREESTANDING...