background image

10

1. This appliance is to be installed by a licensed service person only.
2. This appliance shall be installed in accordance with the manufacturer’s

installation instructions, local gas fitting regulations, municipal building

codes, electrical wiring regulations, and AS5601 the Australian Stand-

ard for gas installations. Refer also to AS5601 for pipe sizing tables.

THIS HEATER IS NOT INTENDED FOR FIRE PLACE INSERT.

Clearances

3. Ensure the minimum clearances to combustible construction are main-

tained during installation, including adequate space for the proper

operation and servicing of the heater.

For clearances to curtains and furnishing refer to warning 3 & 4 on

page 4.

For minimum clearances refer fig 9 and 10.

4.   Remove the carton from the heater and lift from pallet.

Check that the heater is suitable for the gas available. Refer to the data

label located on fan chamber base, rear of pedestal front.
(Please dispose of packaging appropriately, keep away from children).

5. Prepare electrical and gas connections, a 10 Amp wall socket  needs

to be located within 1.5m of the heater.
Note: if flexible cord is damaged, disconnect from supply socket. Re-

move the damaged flex and replace with spare-part assembly F2799.

6. Fit rear spacers as per figure 10.

Installation

7. Place heater in position. (Check flue and gas connection positions.

Refer to gas connection instructions on page 12 and flue installation

instructions on pages 16 & 17).

10

Installation instructions

9

15

23. Follow User Instructions to turn on heater and test for correct operation

before leaving.

24.The heater flames should be stable, not lifting from burner and the logs

should glow after approximately 15 minutes operation on HIGH set-

ting.

The heater has been designed to burn with luminous flames, which

mimic natural log combustion, and may exhibit slight carbon deposits.

If heavy carbon deposits occurs or flames impinge on the roof of the

combustion chamber, turn the appliance off and contact the service

agent in your state.

25.If after following these installation instructions and the trouble shooting

chart on page 20-21, the heater does not perform correctly contact the

service agent in your state. For details of service agents please refer

page 19.

Installation tips

Make sure that the heater is fully commissioned and be certain to con-

duct a test of the integrity of the flue operation, taking into account any

influences created by range-hoods, exhaust fans, central heating, etc.

To avoid any unnecessary delays and inconvinience to your customer,

please contact our Technical Services Department on 1300 727 421,

if the installation is unusual or you have any concerns with the installa-

tion and/or heater operation before the installation commences.

Any service request resulting from incorrect installations are not covered

by our warranty conditions and these calls will result in charges, usually

to the end user, so please be sure that the installation and commission-

ing has been satisfactorily carried out before calling for a warranty

service.

Please make sure that the end user is fully instructed on how to operate

the heater.

Summary of Contents for FITZFS-SDSEB-NG

Page 1: ...proved for use with Natural and Propane gases Please leave instructions with the owner FITZROY FREESTANDING USER INSTRUCTIONS INSTALLATION INSTRUCTIONS SERVICE INSTRUCTIONS FREESTANDING MODELS FITZFS...

Page 2: ...g installation Gas control Gas pressure point Installation tips Flue installation 16 17 Flue kit Service instructions 18 20 General To replace primary glass To replace outer glass To replace the gas c...

Page 3: ...ith manufacturer s instruc tions this warranty may be void The customer must keep their Tax Invoice as proof of purchase of this product and compliance certificate as proof of required installation Mo...

Page 4: ...ammable material on or near the heater 4 Keep curtains clothing furniture and other flammable materials at least 900mm from front rear and sides of the heater At the owner s discretion curtain clearan...

Page 5: ...Testing the effectiveness of the flue Before testing the flue confirm air vents are unobstructed If an exhaust fan or other heating appliances are present switch them on This is to test that there is...

Page 6: ...ol lay out refer to figure 2 3 To turn heater on press switch to POWER ON position There is a 5 second delay before the burner ignites At this setting the burner is on LOW and the fan speed is on LOW...

Page 7: ...switch for LOW setting Refer figure 7 On low burner setting it is more efficient to operate the fan speed on LOW 8 If the burner fails to ignite wait 20 seconds and repeat the ignition procedure See...

Page 8: ...heater fitted with the glass front All cleaning should be carried out when the heater is cold Clean the outer glass with a liquid solution such as Windex or similar Do not use harsh abrasive cleaners...

Page 9: ...essure 1 13 kPa Nat Gas 2 75 kPa Propane Fan 3 speed Controller Electronic direct spark Power requirement 240 VAC 10 Amp Power consumption 90 VA maximum Optional Accessories Silver trim Cathedral ceil...

Page 10: ...d furnishing refer to warning 3 4 on page 4 For minimum clearances refer fig 9 and 10 4 Remove the carton from the heater and lift from pallet Check that the heater is suitable for the gas available R...

Page 11: ...e either side Refer figure 12 10 Remove the heater front by pulling it towards you gently to partly disengage it from the body of the heater then gently lift it up vertically to completely disengage i...

Page 12: ...ront log No 4 Right back log Position the four individually numbered logs in the following order on the burner head as shown in figures 17 20 The male locating pins in the burner head must engage with...

Page 13: ...rope Check that the gas pressure is correctly adjusted If the heater still does not operate to specification refer to the trouble shooting chart on pages 20 21 or contact Sampford IXL in your state P...

Page 14: ...clockwise to decrease pressure 20 Switch the heat button back to Low Flame position as indicated in figure 25 a retain spanner in position and using a screwdriver as per figure 25 b adjust the central...

Page 15: ...service agents please refer page 19 Installation tips Make sure that the heater is fully commissioned and be certain to con duct a test of the integrity of the flue operation taking into account any...

Page 16: ...s have been observed For clearances refer page 10 2 The centre line of the flue is 115mm to rear of appliance including rear spacers 3 Carry out installation as per figure 26 ceiling plate installatio...

Page 17: ...17 27...

Page 18: ...tion instructions 2 The blue module ignition device needs to be removed to allow re moval of the gas control Remove LH screw from front lower section of ignition device Remove screw from front of rect...

Page 19: ...rgise dependant on room temperature The burner should now operate on high setting To replace the fan pressure switch 1 Remove the lower pedestal front by unscrewing four M3 screws Refer page 11 figure...

Page 20: ...e to this appliance For service to this appliance or spare parts contact the CANNON distributor Sampford IXL 52 70 Sparks Avenue Fairfield Vic 3078 Phone 1300 727 421 Fax 1300 727 425 email service sa...

Page 21: ...way switch connector will be energised as soon as the flame has been sensed 5 Confirm spark is produced A blue spark can be seen when the heater ignition when heater is turned on process starts Ensure...

Page 22: ...than 1 5 micro amps at all times Take precaution because the ionisation probe can have a high negative voltage and can cause shock 11 Fuse blowing If the fuse continues to blow check the solenoid coi...

Page 23: ...23...

Page 24: ...INS S F F F Part No F2904 Revision D 2009 Cannon FITZROY FREESTANDING...

Reviews: