4
Please read this manual before installing and using the heater.
What to do if you smell gas
1. Turn OFF the main gas supply.
2. Extinguish any open flame.
3. Open windows.
4. Do not touch electrical switches.
5. Do not use your telephone.
6. Call your gas supplier immediately from a neighbour’s phone.
Warnings
1. Improper installation, adjustment, alteration, service or maintenance
can cause injury or property damage. Refer to other sections of this
manual for correct procedures, or consult with place of purchase, a
licensed plumber, a gas supplier or the CANNON distributor listed in
this manual.
2. Do not build the heater into bookcases or walls. Install only as referred
to in these installation instructions.
3. Due to high temperatures the room heater should be located out of
traffic and away from:
•
Furniture and draperies,
•
Combustible materials,
•
Gasoline and other flammable liquids,
Do not place clothing or other flammable material on or near the heater.
4. Keep curtains*, clothing, furniture and other flammable materials at
least 900mm from front, rear and sides of the heater.
* At the owner’s discretion curtain clearance can be less than 900mm
as long as they are restrained from the front, top and sides of the heater.
The manufacturer takes no responsibility if curtain clearance is less than
900mm and not restrained.
5. Children and adults should be alerted to the hazard of high surface
temperature and should take care to avoid burns or clothing ignition.
This appliance is not intended for use by persons (including chil-
dren) with reduced physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have been given super-
vision or instruction concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that they do not play with
the appliance.
6. Never attempt to burn paper or any other material in the heater.
7. Do not place articles on or against this appliance.
Do not use or store flammable materials near this appliance.
Safety warnings
21
To check the operation of the electronic (module) controller (Type 537 ABC) you will require a digital
multimeter with the functions to measure AC/DC voltage, continuity, resistance and micro-amps.
It is critical that the appliance is earthed and that the active and neutrals are not reversed.
Item No
Check
Action
1.
No ignition when appliance
• Check 240 volts power to heater in incoming plug
is turned on.
connector.
2.
Power present but appliance
• If there is power to the brown wire in the 8 way
not operating.
switch connector the module may be in lockout
mode. To reset the module turn off the power supply
for 10 seconds and then turn the power on again.
3.
After resetting the module
• Check the internal 2-A fuse in the loom.
and appliance is still not
operating.
4.
If the fuse is O.K. and still
• Check other connections are in place.
appliance not operating
• If the last checks are correct the ignition electrode
should spark at the same time as the gas control
solenoid valves open. At this point the spark
electrode will activate for up to 10 seconds maxi
mum until the flame has been established. Terminal
14 (white wire into the 8 way switch connector)
will be energised as soon as the flame has been
sensed.
5.
Confirm spark is produced
• A blue spark can be seen when the heater ignition
when heater is turned on.
process starts. Ensure spark is present between
electrode and burner.
6.
If no spark being produced
•
Check that spark lead is connected into module.
•
Check the continuity of the HT cable.
•
Check that there is no short circuit to earth and
spark gap is correct. (Refer figure 28). A positive
check is to use a jumper wire and connect one end
of the earth and hold the other end with insulated
pliers 4mm from the spark generator on the module.
If there is no spark to earth then change the module.
7.
Spark is being produced
• Listen for cracking sound. The spark is misdirected.
but not at burner.
Check the spark ceramic insulator for signs of
cracks.
8.
Sparks, ignites on low flame
• Check that the wall socket to the appliance has
then extinguishes after 10
correct polarity. Do not use an extension cord. Check
seconds. Continues to spark
polarity in the electrical supply lead to appliance.
during flame presence.
• Check that the sense electrode is in the flame.
• Check that appliance is earthed correctly. A check
between the earth pin on the plug and an unpainted
part of the appliance should see a resistance of
0.1 ohms.