8
17
9
Gas type:
Natural or Propane gas, as indicated
on data label
Gas consumption:
26 MJ/hr input
Energy output:
21.45 MJ/hr (5.96 kW)
Energy star rating:
4 stars
Heater type:
Approved to AS4553:2008
Operating pressure:
Natural gas: 0.75 kPa
(at the burner)
Propane gas: 2.65 kPa
Gas regulator:
Integral part of controller
Min. inlet pressure:
1.13 kPa (NG)
2.75 kPa (Propane)
Fan:
3 speed
Controller:
Electronic direct spark
Power requirements:
240 VAC 10 Amp
Power consumption:
90 VA maximum
Minimum cavity
Height: 605mm dimensions*
dimensions
Width: 695mm
Depth:
385mm
Power requirement:
240 VAC 10 A
Optional Accessories:
• Safety guard
• Mock fireplace installation kit*
• Spacer kit
• 3 sided surround
• 4 sides surround in black & stainless
steel
• Console kit
Overall dimensions:
Refer fig. 8
*For installation into a non-combustible fireplace, ie: masonry or brick or into a mock
fireplace, i.e. timber or plasterboard.
Note: when installing into a mock fireplace a mock kit must be used.
Heater specifications
8
Note:
The data plate is located on
the fan chamber base, rear
of the lower fascia.
Gas pressure point
24.The pressure point is closed with a captive screw. Turn screw 6 revolu-
tions anticlockwise to open the pressure point as indicated on figure
33(a) and place manometer tube over the test point as per figure 33(b).
Gas pressure adjustment
26.Switch the stop button back to “Low Flame’ position as indicated in
figure 35(a), retain spanner in position
and using a screwdriver as
per figure 35(b) adjust the central screw control to give a pressure
reading of 0.3 kPa for Natural Gas and 1.1 kPa for LPG. (Turn clock-
wise to increase pressure and anticlockwise to decrease pressure).
27.Switch burners off and remove the manometer tube. Tighten pressure
test point by turning the captive screw fully clockwise.
Replace plastic cap. Ensure the little lug is positioned towards lower
right hand side to clear the control.
28. Refit the lower front cover, making sure not to damage the power cord.
29. Follow User Instructions to turn on heater.
34 a
34 b
35 a
35 a
25.Switch the heater to Hi Flame to as indicated in figure 34(a) and using a
ring spanner, as per figure 34(b), adjust the pressure to 0.75 kPa for
Natural gas or 2.65 kPa for LPG. (Turn clock-wise to increase pressure
and anticlockwise to decrease pressure).