Cannon CANTERBUR User Instructions Download Page 6

6

Operating instructions

1. Plug the power cord into the wall socket and turn on the power to the

heater, see figure 1. Refrain from using an extension cord.

User instructions

1

19

2. For control lay-out refer to figure 2

2

ON/OFF   button
When there is power to the heater but it is on 
standby mode a red LED will blink 
intermittently behind this button. 
 
To turn heater on press the ON/ OFF  button.
 
There will be a 5 second delay before the 
burner ignites. At this setting the burner is on 
low flame / low fan for 3 minutes. During the 
ignition process the red LED will glow.

The red LED  will fade out after 30 seconds 
when the ignition process is complete.

Pressing the heat setting buttons will set the 
heater to HIGH , MEDIUM  or LOW heat.

 The fan is set to a corresponding speed  for 
each setting.

To turn the heater off press the ON OFF 
button.

If the burner fails to ignite, wait 20 seconds 
and then press the ON OFF button.

In case of power failure, when the power 
returns, wait 20 seconds for any unburnt gas 
to vent and start reignition by pressing the ON 
OFF button.

ON / OFF

LOW

MEDIUM

HIGH

    

Service instructions 

(Do not modify this appliance)

General

1. Service work to be carried out by an authorised service person only.
2. Unplug from wall socket or turn off power at main switchboard if heater

is hard wired.

3. Always shut off the gas supply and ensure that the heater is cool before

commencing any service operations.

4. Always check for gas soundness after servicing.

To replace the primary glass

1. Refer pages 13 and 14, steps 7 to 11, of the installation instructions.

Refit glass and replace in reverse order ensure the inside surface of the
glass is clean and free from finger marks.

To replace the outer glass

1. Remove the outer glass, refer page 13, fig 15.
2. Loosen bottom glass frame and remove top glass frame.
3. Replace glass and refit in reverse order.
Note: ensure the inside surface of the glass is clean and free from finger
marks.

To replace the gas control

1. Remove the lower front cover by unscrewing two M5 screws through

the air intake slot. Refer page 13, figure 16, of the installation instructions.

2.  Unplug  the cables from the gas control and disconnect the earth connection.
3.  Disconnect the gas inlet (1/2” compression nut) connection at entry
     gas control and the 16mm nut at the outlet of the gas control.
4.  Remove the three M3 screws from the cradle retaining the gas control.
5.  Remove gas control.
6.  Replace gas control  in reverse order and check for gas tightness

Note: check the gas pressure on high and low burner settings. Refer ‘gas control’, 
pages 13 and 14

To replace the ignition (module) device

1. Unplug wire connectors from ignition module.
2.   Remove module mounting bracket by removing  
mounting screw.
3. Using pliers bend tabs so that module can come 
away from the mounting bracket.

4. Replace ignition device in reverse order.

Ignition module

Mounting bracket

Summary of Contents for CANTERBUR

Page 1: ...service sampfordixl com au Date installed Compliance Certificate No Cannon This heater is approved for use with Please leave instructions with the owner 24 Sampford IXL spare parts 52 70 Sparks Avenu...

Page 2: ...er sparks If there is no gas to the burner when this occurs check the solenoid coils for continuity Check that the gas pressure is present at the test point when the spark is being generated Check tha...

Page 3: ...w the heater to function Check operation of fan pressure switch If room circulation fan is operating the pressure switch should energise and allow ignition sequence 2 Power present but appliance If th...

Page 4: ...ning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance 6 Never attempt to burn paper or any other material...

Page 5: ...ed to this appliance to reduce the risk of fire or injury from burns and no part of it should be permanently re moved For protection of young children or the infirm a secondary guard is required Stand...

Page 6: ...and ensure that the heater is cool before commencing any service operations 4 Always check for gas soundness after servicing To replace the primary glass 1 Refer pages 13 and 14 steps 7 to 11 of the i...

Page 7: ...aling rope Check that the gas pressure is correctly adjusted If the heater still does not operate to specification refer to the trouble shoot ing chart on pages 22 and 23 or contact Samford IXL in you...

Page 8: ...r of the lower fascia Gas pressure point 24 The pressure point is closed with a captive screw Turn screw 6 revolu tions anticlockwise to open the pressure point as indicated on figure 33 a and place m...

Page 9: ...ane the gas pressure must be set at 2 65 kPa with burner operating on maximum setting On Natural Gas the gas pressure must be set at 0 75 kPa Plastic Cap Pressure adjustment Burner Full on Burner adju...

Page 10: ...a Place log No 1 onto the 2 front left pins on the burner head ensuring that the charring faces the front Refer figure 26 b Place log No 2 onto the 2 left back pins Refer figure 27 c Place log No 3 o...

Page 11: ...nection figure 24 14 With heater in position flanges should be hard against masonry Se cure case flanges to masonry Refer figure 23 15 Connect incoming gas supply pipe to regulator For inlet position...

Page 12: ...rd ensure that the cord cannot be trapped when the heater is installed 9 To remove the front heater surround undo two s t screws one either side from the bottom flange of the front panel as indicated...

Reviews: