Cannon CANTERBUR User Instructions Download Page 1

CANTERBURY

INBUILT MODELS

USER INSTRUCTIONS

INSTALLATION INSTRUCTIONS

SERVICE INSTRUCTIONS

Part  No:  F2901
RevisionG- 2010

Cannon

For service to this appliance  or spare
parts contact the CANNON distributor:

email: service@sampfordixl.com.au

Date installed: ........................................

Compliance Certificate No .........................

Cannon

This heater is approved for use with 

Please leave instructions with the owner

24

Sampford IXL (spare parts)

52 - 70 Sparks Avenue
Fairfield, Vic, 3078
Phone: 1300 727 421
Fax:

1300 727 425

Data label

Gmk10025

AS4553:2008

Natural and Propane gases.

Stick copy of data label here!

PLEASE READ THIS MANUAL 

BEFORE INSTALLING AND

USING THIS HEATER.

Summary of Contents for CANTERBUR

Page 1: ...service sampfordixl com au Date installed Compliance Certificate No Cannon This heater is approved for use with Please leave instructions with the owner 24 Sampford IXL spare parts 52 70 Sparks Avenu...

Page 2: ...er sparks If there is no gas to the burner when this occurs check the solenoid coils for continuity Check that the gas pressure is present at the test point when the spark is being generated Check tha...

Page 3: ...w the heater to function Check operation of fan pressure switch If room circulation fan is operating the pressure switch should energise and allow ignition sequence 2 Power present but appliance If th...

Page 4: ...ning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance 6 Never attempt to burn paper or any other material...

Page 5: ...ed to this appliance to reduce the risk of fire or injury from burns and no part of it should be permanently re moved For protection of young children or the infirm a secondary guard is required Stand...

Page 6: ...and ensure that the heater is cool before commencing any service operations 4 Always check for gas soundness after servicing To replace the primary glass 1 Refer pages 13 and 14 steps 7 to 11 of the i...

Page 7: ...aling rope Check that the gas pressure is correctly adjusted If the heater still does not operate to specification refer to the trouble shoot ing chart on pages 22 and 23 or contact Samford IXL in you...

Page 8: ...r of the lower fascia Gas pressure point 24 The pressure point is closed with a captive screw Turn screw 6 revolu tions anticlockwise to open the pressure point as indicated on figure 33 a and place m...

Page 9: ...ane the gas pressure must be set at 2 65 kPa with burner operating on maximum setting On Natural Gas the gas pressure must be set at 0 75 kPa Plastic Cap Pressure adjustment Burner Full on Burner adju...

Page 10: ...a Place log No 1 onto the 2 front left pins on the burner head ensuring that the charring faces the front Refer figure 26 b Place log No 2 onto the 2 left back pins Refer figure 27 c Place log No 3 o...

Page 11: ...nection figure 24 14 With heater in position flanges should be hard against masonry Se cure case flanges to masonry Refer figure 23 15 Connect incoming gas supply pipe to regulator For inlet position...

Page 12: ...rd ensure that the cord cannot be trapped when the heater is installed 9 To remove the front heater surround undo two s t screws one either side from the bottom flange of the front panel as indicated...

Reviews: