![background image](http://html1.mh-extra.com/html/candk-systems/system-238/system-238_installation-manual_3074139009.webp)
SYSTEM 238 Installation Manual
9
Command Locations 09 and 0A
Command Location 09: Arming/Combination Options
(1)
(2)
(3)
(4)
0
0
1
1
Default Values
0
9
Digit Position (2): Combination Command
0 = No
1 = Yes; requires combination for Bypass, Group Bypass, Instant Arm, keypad
activated RPS, and Test (central station and bell)
Digit Position (3): Default Installer Combination
0 = No; this enables the Pirate-Guard
TM
feature for added security
1 = Yes; combination changes back to factory value on power loss
Digit Position (4): Faulted Arming Type
1 = Goof-Proof: zones must be normal or shunted to arm
2 = Force Arm: faulted zones will be shunted at end of Exit Delay
3 = Chirp Alert: faulted delay zones will chirp bell during Exit Delay
Command Location 0A: Communications Formats
(1)
(2)
(3)
(4)
1
2
1
2
Default Values
0
A
Digit Position (1): Receiver #1 Receiver Format
Digit Position (2): Receiver #1 Message Format
1 = 3/1 single
2 = 3/1 extended
3 = 4/2 (2-digit reporting code)
4 = 4/1
5 = CFSK III
6 = 4/9 Ademco DTMF
7 = 4+2 SumCheck
5 = CFSK III
6 = DTMF, 1400 Hz
3 = SumCheck, 1400 Hz
4 = SumCheck, 2300 Hz
1 = Fast "A", 2300 Hz
2 = Slow "B", 1400 Hz
Digit Position (3): Receiver #2 Receiver Format
1 = Fast "A", 2300 Hz
2 = Slow "B", 1400 Hz
3 = SumCheck, 1400 Hz
4 = SumCheck, 2300 Hz
5 = CFSK III
6 = DTMF, 1400 Hz
Digit Position (4): Receiver #2 Message Format
3 = 4/2 (2-digit reporting code)
4 = 4/1
1 = 3/1 single
2 = 3/1 extended
5 = CFSK III
6 = 4/9 Ademco DTMF
7 = 4+2 SumCheck
(DTMF)
(DTMF)
0 = Guest Time Disabled
1 = 1 day
2 = 2 days
3 = 3 days
4 = 4 days
5 = 5 days
6 = 6 days
7 = 7 days
8 = 8 days
9 = 9 days
Digit Position (1): Guest Combination Time
0 = 10 days
1 = 11 days
2 = 12 days
3 = 13 days
4 = 14 days
5 = 15 days
#
#
Message Format
Receiver Format(s)
SumCheck (DTMF)
DTMF, 1400 Hz only
CFSK III
CFSK III only
Valid combinations of Receiver Format and Message Format are listed below.
3/1 Single or 3/1 Extended
All formats, except CFSK III and DTMF, 1400 Hz
4/1 or 4/2 (2-digit reporting)
Fast "A", 2300 Hz and Slow "B", 1400 Hz only