SYSTEM 238 Installation Manual
15
Command Location 27: Soft Zone A (EMERGENCY)
Digit Positions (1) and (2): Emergency Zone Code Report
(1)
(2)
(3)
(4)
0
0
1
3
Default Values
2
7
#
Only Position (1) is sent for 3/1 and 4/1 formats.
Positions (1) and (2) are sent for 3/1 Extended, 4/2, and CFSK formats.
Program 00 to disable alarm reporting for Emergency zone.
Digit Position (3): Emergency Zone Receiver Select
Digit Position (4): Emergency Zone Loop Bell Type
1 = Pulsing
2 = Steady
3 = Chirp
4 = Silent
Command Location 28: Soft Zone B (Fire)
(1)
(2)
(3)
(4)
0
0
1
1
Default Values
2
8
#
Digit Position (4): Fire Zone Loop Bell Type
Digit Position (3): Fire Zone Receiver Select
Digit Positions (1) and (2): Fire Zone Report Code
Command Location 29: Soft Zone C (Police)
Digit Positions (1) and (2): Police Report Code
(1)
(2)
(3)
(4)
0
0
1
2
Default Values
2
9
#
Digit Position (3): Police Zone Receiver Select
Digit Position (4): Police Loop Bell Type
PROGRAMMING CONVERSIONS
Hexadecimal Value
Key Strokes
A
B
C
D
E
F
0
1
2
3
4
5
0 = Receiver 1 with Receiver 2 as back-up
1 = Receiver 1 only
2 = Receiver 2 only
3 = Receiver 1 and Receiver 2 (Dual Reporting)
NOTE: Command Location 2F Digit Position (4)
must be programmed to YES to enable
Soft Zones.
Refer to CL 27 for information about
programming this zone.
Refer to CL 27 for information about
programming this zone.
This Zone is identified by the "E" key
on the Alpha II and LED keypads.
This Zone is identified by the "F" key
on the Alpha II and LED keypads.
This Zone is identified by the "P" key
on the Alpha II and LED keypads.
Command Locations 27 - 29