SYSTEM 238 Installation Manual
19
Command Locations 30 - 37: Loop Switches
30 = Loop 1
31 = Loop 2
32 = Loop 3
33 = Loop 4
Digit Position (1): Enable Door Chime
(1)
(2)
(3)
(4)
0
0
0
0
3
0
34 = Loop 5
35 = Loop 6
36 = Loop 7
37 = Loop 8
**Default Values are different for each loop.
Refer to the SYSTEM 238 Programming
Worksheet at the end of this manual for
other default values.
**Default Values
#
0 = No
1 = Yes: keypads beep 2 seconds when faulted (disarmed condition)
Digit Position (2): Allow Shunting of This Loop
0 = No: makes it a priority zone (not shuntable)
1 = Yes: authorized users can bypass or force arm
Digit Position (3): Allow Group Shunting for This Loop
0 = No
1 = Yes: include as part of group when performing Home Arming or Instant/Home Arming feature (See also pages 21 & 25)
Digit Position (4): Delay Before Dial
0 = No
1 = Yes: this loop will delay dialing on alarm for time programmed in 0B (1)
Command Location A0: Set Test Report Countdown Timer
Digit Position (1): Set Countdown Timer
A
0
(1)
#
0 = 1/4 hour
1 = 1/2 hour
2 = 1 hour
3 = 2 hours
4 = 3 hours
5 = 4 hours
6 = 6 hours
7 = 8 hours
8 = 10 hours
9 = 12 hours
0 = 14 hours
1 = 16 hours
2 = 18 hours
3 = 20 hours
4 = 22 hours
5 = 24 hours
NOTE: Refer to CL 2B (4) for setting the
time interval between Reports.
Example:
The time is 1500 hours (3:00 pm). You want the first Test Report to
transmit at 0100 hours (1:00 am). 3:00 pm + 10 hours = 1:00 am.
Program the value "8" in Memory Location A0.
PROGRAMMING CONVERSIONS
Hexadecimal Value
Key Strokes
A
B
C
D
E
F
0
1
2
3
4
5
Refer to CL 01 - 08 Digit Position (1) for
Arming Types (Authorization Levels).
Previously stored data is not displayed during programming.
This command will set the time when the first Test Report is transmitted to the central station.
The panel will use this transmission time each time it's powered up or the CPU is reset (unless
Command Location A0 is reprogrammed).
Command Locations 30 - 37 & A0