Maintenance

 

 

Change Filters 

 
Your  system  contains  filters  which  must  be  replaced 
periodically  for  proper  operation.    (Please  see  Page  2  for 
general filter change schedule) 

NOTE:

   Filter cartridges may require changing more 

frequently depending on the source water conditions. 
 
In  each  filter  head  there  is  an  automatic  shut-off  device 
which  allows  the  filters  to  be  changed  without  having  to 
turn off the inlet water supply. 
 
To change filters follow the procedures in figure 5 below. 

NOTE: 

Expect  a  few  drops  of  water  when  removing  the 

filter cartridge. 
 
 
 
 
 
 
 
 
 
 
 

Change Membrane 

 

Your  system  contains  a  reverse  osmosis  membrane  which 
should  be  replaced  periodically  for  proper  operation.   
(Please see Page 2 for general filter change schedule) 

NOTE:   

RO  Membrane  may  require  changing  more 

frequently depending on the source water conditions. 
 
To change filters follow the procedures below: 
 
1.

Turn  off  water  supply  by  turning  feed  water  saddle 
valve clockwise until valve is fully closed. 

2.

Turn storage tank valve clockwise to close. 

3.

Open faucet to relieve pressure. 

4.

Remove quick connect fittings from RO Membrane. 

5.

Re-connect RO Membrane. 

6.

Turn water supply back on. 

7.

Turn storage tank valve to open position. 

8.

Empty storage tank.  Produce an additional full tank of 
water and discard it.  Normal operation can resume.

 

 
 
 

 
 

 

 
 

 

Figure 5. Filter Installation 

Figure 6. RO Membrane 

 

Water Pressure and Temperature 
 

Product  water  quality  and  production  of  RO  systems  is 
dependent  on  pressure  and  temperature.    Typically,  RO 
membranes are rated at standard conditions of 77F (25 C)  
and 60 psi (4 bar) discharging to atmosphere.  In general, 
the  higher  the  pressure  differential  and  temperature, 
increased quality and quantity of water is produced.  These 
factors should be considered when sizing RO systems for a 
particular application. 

 

Quick Connect Fittings 

 
The  475  PRO  Series  system  utilizes  quick-connect  fittings.  
Proper use of these push-in fittings is shown below.  Along 
with  these  fittings,  all  tubing  selected  must  be  of  high 
quality and must be cut with a plastic tube cutter or sharp 
razor with a clean, square cut. 
 
Should  a  leak  occur  at  a  fitting,  the  cause  is  generally 
defective  tubing.    To  fix  a  leak,  relieve  pressure,  release 
tubing,  cut  off  at  least  ¼``  from  the  end  (square  cut), 
reattach  the  tubing  and  confirm  the  connection  is  leak-
free.  Each time a new connection is made, it is advisable 
to cut of ¼`` from the end of the tubing using these fittings. 
 

Cut the tube square and remove 
burrs  and  sharp  edges.  Ensure 
that the outside diameter is free 
from  score  marks.  For  soft  or 
thin  walled  plastic  tubing  we 
recommend  the  use  of  a  tube 
insert. 

Push the tube into the fitting and 
up to the tube stop. 

Pull on the tube to check that it 
is  secure.  Test  the  system 
before use. 

To  disconnect,  ensure  that  the 
system  is    depressurized,  push 
the  collet  square  against  the 
fitting. With the collet held in this 
position  the  tube  can  be 
removed. 