3. Drain Saddle Valve Installation 

 

Prior to proceeding it  is important to inspect the condition 
of drain pipes to make sure they are not thin and frail.  
Drain saddle valves are designed to be installed on 
standard 1-1/2`` OD drain pipe.   
 
Install drain saddle valve above (and before) the trap 
and on the vertical or horizontal tailpiece. Never install a 
drain saddle valve close to the outlet of a garbage disposal 
or plugging of the RO drain line may result .  Refer to 
Figure 1. 
 
1.

Position half of drain saddle valve with quick connect 
fitting at selected location and mark for the opening. 

2.

Drill ¼`` hole at mark through one side of pipe.  
Position both halves of drain saddle on drain pipe so 
quick connect opening lines with hole. 

3.

Secure drain saddle clamp on valve with bolts and nuts 
provided.  (Do not over tighten and make sure there is 
equal space between saddle halves on each side). 
 
 
 
 
 
 
 
 
 
 
 
 

4. Filter Cartridge Installation 

 

Install cartridge filters into RO unit.  (Also refer to figure 1.) 
 
 
 
 
 
 
 
 
 
 
 

 
5. RO Unit Installation 

 

The  unit  is  normally  mounted  to  the  right  or  left  sink 
cabinet sidewall.  To mount the unit, elevate it at least 3`` 
off  the  floor,  level  it  and  mark  the  location  of  mounting 
holes needed.

 

Figure 3. Drain Saddle Valve 

 

Drill holes for mounting screws and install screws, allowing 
the mounting bracket  slots to slip over them.   
 
NOTE: If the cabinet sidewalls are not solid, unit may sit on 
the  floor  with  screws  to  keep  it  against  the  cabinet  in  a 
vertical position. 

 
6.  Tubing Connections 

 

 With  all  components  in  place,  complete  final  tubing 
connections using these guidelines: 
 

  Tubing should follow contour of the cabinets 

  Cut  tubing  to  desired  length  using  square  cuts  and 

proper cutting device 

  Make no sharp bends 

  Keep  tubing  from  the  unit  to  the  faucet  as  short  as 

practical for good flow 

 

Procedure 

 

1.

Connect 3/8” tubing from faucet to RO unit. 

2.

Connect 3/8” tubing from tank to RO unit. 

3.

Connect ¼” tubing from supply valve to RO unit. 

4.

Connect ¼” tubing from drain valve to RO unit. 

 

7. System Start-Up 

 

1.

Check all connections to be sure they are secure. 

2.

Turn on feed water  valve and check  for leaks.  (Turn 
off and correct leaks if leaks occur). 

3.

Close faucet and wait a reasonable amount of time to 
see if leaks result. 
 

8. Flush System and Check Operation 

 

1.

Open  faucet  handle  and  allow  tank  to  completely 
drain  of  sanitizing  solution.    Do  not  use  this  water.   

NOTE:

    When  tank  is  empty,  faucet  will  steadily  drip.  

This is the rate the RO system processes water. 

2.

Close faucet and re-inspect system for leaks. 

3.

Allow system to process water for approximately four 
hours, at which point tank will be practically full. 

4.

Open  faucet  again  and  allow  tank  to  empty  for  a 
second time.  Do not use this water. 

5.

Wait  another  four  hours  to  allow  tank  to  re-fill.    

NOTE:

    If  no  objectionable  tastes  are  noticed  after 

second tank draining, RO processed water is ready for 
use.  Otherwise, drain tank and re-fill for a third time. 

 