CS6v-xxxp and CS6v-xxxM

Use four clamps on the long side. Mounting rails 
run perpendicularly to the long side frame. 

Use four clamps on the short side. Mounting rails 

run parallel to the long side frame

A1 range = (0 – 239) mm
Maximum Load: Uplift load ≤ 2000 Pa
                              Downforce load ≤ 2000 Pa

Use four clamps on the short side.

A2 range=(170 – 210) mm
Maximum Load: Uplift load ≤ 2400 Pa
                              Downforce load ≤ 2400 Pa

Use four clamps on the short side and two 

clamps on the long side. An additional support 

bar should be placed below the center of the 

module.

A1

A1

A1

A1

A1 range = (240 – 550) mm
Maximum Load: Uplift load ≤ 2400 Pa
                              Downforce load ≤ 2400 Pa
A1 range = (240 – 330) mm
Maximum Load: Uplift load ≤ 2400 Pa
                              Downforce load ≤ 5400 Pa

A2 range = (0 – 210) mm
Maximum Load: Uplift load ≤ 2000 Pa
                              Downforce load ≤ 2000 Pa

A2 range = (200 – 250) mm
Maximum Load: Uplift load ≤ 2400 Pa
                              Downforce load ≤ 5400 Pa

       

A2

A2

A2

A2

A2

A2

A2

A2

A2

A2

A2

A2

·  The mounting method has been qualified by 

Canadian Solar Inc. and certified by VDE and CSA.

·  Insertion methods can vary and depend on the 

mounting structures. The installer needs to follow 

the mounting guidelines recommended by the 

mounting system supplier. Each module must 

be securely maintained through all its length 

on two opposite sides. Install and tighten the 

insertion profiles to the support structure using 

the hardware and instructions provided by the 

mounting system manufacturer. System designer 

and installer are solely responsible for load 

calculations and for the proper design of support 

structure. 

·  Canadian Solar Inc. warranty may be void in cases 

where improper insertion systems or unsuitable 

installation methods are found. When installing 

insertion profiles, please take the following 

measures into account:

1.Do not bend the module frame
2.Do not touch the front glass or cast shadow onto it
3.Do not damage the surface of the frame
4.Ensure that the insertion profiles overlap the 

module frame by at least 10 mm (0.39 in).

5.Ensure that the module frame (C-shape) overlaps 

the insertion profiles by at least 15 mm (0.59 in).

6.Ensure insertion profile thickness and tolerances 

suit module thickness  of 40 mm (1.57 in)  
modules).

CS6k- xxxMS

Use four clamps on the long side. Mounting rails 
run perpendicularly to the long side frame. 

A1 range = (310 – 350) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa

A1

A1

A1

A1

MOUNTINg METhOD B: 
INSERTION SySTEMS

Use four clamps on the long side. Mounting rails 
run paralel to the long side frame. 

A1

A1

A1

A1

A1 range = (240 – 330) mm
Maximum Load: Uplift load ≤ 2400 Pa
                              Downforce load ≤ 4000 Pa

Summary of Contents for CS6P-P Series

Page 1: ...INSTALLATION MANUAL ANNEX OF STANDARD SOLAR MODULE For professional use only...

Page 2: ...0 ft lbs for M8 coarse thread bolts depending on the bolt class For the bolt grade the technical guideline from the fastener suppliers need to be followed Different recommendations from speciic clampi...

Page 3: ...50 mm Maximum Load Uplift load 2400 Pa Downforce load 5400 Pa CS6U xxxp and CS6U xxxM Use four clamps on the long side Mounting rails run perpendicularly to the long side frame A1 A1 A1 A1 Use four cl...

Page 4: ...xxxM Use four clamps on the long side Mounting rails run perpendicularly to the long side frame Use four clamps on the short side Mounting rails run parallel to the long side frame A1 range 0 239 mm M...

Page 5: ...ting system supplier Each module must be securely maintained through all its length on two opposite sides Install and tighten the insertion profiles to the support structure using the hardware and ins...

Page 6: ...be placed below the module Use two clamps on the support bar Maximum Load Uplift load 2400 Pa Downforce load 5400 Pa Use two insertion proiles running parallel to the long side frame Maximum Load Upli...

Page 7: ...Clamp installation instructions D PanelClaw Inc Standard Claw integrated grounding PanelClaw Grizzly Bear FR Gen II mounting system Grizzly Bear FR Gen II Installation Manual 9910010 Rev A E Array ech...

Page 8: ...53 15 00 Table 1 Mechanical And Electrical Ratings under STC ANNEX C MEChANICAL AND ELECTRICAL RATINgS Module Type Maximum power pmax w Operating voltage vmp v Operating current Imp A Open Circuit vol...

Page 9: ...9 8 94 39 1 9 59 15 00 CS6k 290MS 290 0 32 1 9 05 39 3 9 67 15 00 CS6k 295MS 295 0 32 3 9 14 39 5 9 75 15 00 CS6k 300MS 300 0 32 5 9 24 39 7 9 83 15 00 CS6k 305MS 305 0 32 7 9 33 39 9 9 91 15 00 This...

Page 10: ...ss surface OpERATION pREpARATION Noticeable dirt must be rubbed away by gentle cleaning implement soft cloth sponge or brush with soft bristles Ensure that brushes or agitating tools are not abrasive...

Reviews: