EN-Rev IM/GN-AM-EN/A5 Copyright © June 2016. Canadian Solar Inc.
www.canadiansolar.com
|
9
8
|
CS6v-xxxp and CS6v-xxxM
Use four clamps on the long side. Mounting rails
run perpendicularly to the long side frame.
Use four clamps on the short side. Mounting rails
run parallel to the long side frame
A1 range = (0 – 239) mm
Maximum Load: Uplift load ≤ 2000 Pa
Downforce load ≤ 2000 Pa
Use four clamps on the short side.
A2 range=(170 – 210) mm
Maximum Load: Uplift load ≤ 2400 Pa
Downforce load ≤ 2400 Pa
Use four clamps on the short side and two
clamps on the long side. An additional support
bar should be placed below the center of the
module.
A1
A1
A1
A1
A1 range = (240 – 550) mm
Maximum Load: Uplift load ≤ 2400 Pa
Downforce load ≤ 2400 Pa
A1 range = (240 – 330) mm
Maximum Load: Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa
A2 range = (0 – 210) mm
Maximum Load: Uplift load ≤ 2000 Pa
Downforce load ≤ 2000 Pa
A2 range = (200 – 250) mm
Maximum Load: Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
· The mounting method has been qualified by
Canadian Solar Inc. and certified by VDE and CSA.
· Insertion methods can vary and depend on the
mounting structures. The installer needs to follow
the mounting guidelines recommended by the
mounting system supplier. Each module must
be securely maintained through all its length
on two opposite sides. Install and tighten the
insertion profiles to the support structure using
the hardware and instructions provided by the
mounting system manufacturer. System designer
and installer are solely responsible for load
calculations and for the proper design of support
structure.
· Canadian Solar Inc. warranty may be void in cases
where improper insertion systems or unsuitable
installation methods are found. When installing
insertion profiles, please take the following
measures into account:
1.Do not bend the module frame
2.Do not touch the front glass or cast shadow onto it
3.Do not damage the surface of the frame
4.Ensure that the insertion profiles overlap the
module frame by at least 10 mm (0.39 in).
5.Ensure that the module frame (C-shape) overlaps
the insertion profiles by at least 15 mm (0.59 in).
6.Ensure insertion profile thickness and tolerances
suit module thickness of 40 mm (1.57 in)
modules).
CS6k- xxxMS
Use four clamps on the long side. Mounting rails
run perpendicularly to the long side frame.
A1 range = (310 – 350) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa
A1
A1
A1
A1
MOUNTINg METhOD B:
INSERTION SySTEMS
Use four clamps on the long side. Mounting rails
run paralel to the long side frame.
A1
A1
A1
A1
A1 range = (240 – 330) mm
Maximum Load: Uplift load ≤ 2400 Pa
Downforce load ≤ 4000 Pa