| 21
EN-Rev IM/GN-BM-EU/1.93 Copyright © August, 2021. CSI Solar Co., Ltd.
www.csisolar.com
Tracker 1P Clamping method
Overlap width between clamp and
frame:
Frame top side ≥ 10mm
Frame bottom side ≥ 15mm
Module type
B Value (mm)
Clamp length C
(mm)
Test load
(Pa)
CS3W-PB-AG
CS3W-MB-AG
≥400
≥40
+2400/-1800
≥80
+2400/-2400
CS3Y-MB-AG
CS3Y-PB-AG
CS6W-MB-AG
≥400
≥40
+1800/-1800
CS7L-MB-AG
≥400
≥40
+1600/-1600
CS7N-MB-AG
≥400
≥40
+1500/-1500
Tracker 2P Bolting method
Module type
Mounting
hole space
(mm)
Mounting
hole location
Plain washer
outer
diameter
(mm)
Test load
(Pa)
CS3W-PB-AG
CS3W-MB-AG
A1-A3: 400
B1-B3: 1155
B1, B2, A3, A4
16
+1800/-1600
B1, B2, B3, B4
16
+2200/-2000
CS3Y-MB-AG
CS3Y-PB-AG
CS6W-MB-AG
CS7L-MB-AG
CS7N-MB-AG
A1-A3: 400
B1-B3: 790
B1, B2, A3, A4
16
+1800/-1600
B1, B2, B3, B4
16
+2200/-2000
The allowable maximum twist angle of the module is
0.5 degree.
Please contact the tracker manufacturer and Canadian
Solar’s technical support department for details in
regard to specific projects.