background image

INSTALLATION

MANUAL OF 

DYMOND MODULE 

For professional use only

Summary of Contents for Dymond CS6K-245P-FG

Page 1: ...INSTALLATION MANUAL OF DYMOND MODULE For professional use only...

Page 2: ...EN Rev IM FDM EN 1 6 Copyright March 2017 Canadian Solar Inc...

Page 3: ...3 0 MECHANICAL ELECTRICAL SPECIFICATIONS 4 0 UNPACKING AND STORAGE 5 0 MODULE INSTALLATION 5 1 MODULE WIRING 5 2 MODULE GROUNDING 6 0 MOUNTING INSTRUCTIONS 7 0 MAINTENANCE AMENDED EDITIONS AND DATES...

Page 4: ...cluding without limitation bodily harm injury or damage to property in connection with handling PV modules system installation or compliance or non compliance with the instructions set forth in this m...

Page 5: ...rical Ratings Main electrical charac teristics under STC are also stated on each module label The maximum system voltage for double glass module type is 1000V UL and 1500V IEC Under certain conditions...

Page 6: ...heavy loads may cause severe micro cracks at cell level which in turn may compromise module reliability Failure to comply with the above caution will void Canadian Solar Inc s warranty SYSTEM FIRE RA...

Page 7: ...ing Only modules with similar electrical outputs should be connected in the same series to avoid or minimize mismatch effects in arrays To minimize risk in the event of an indirect light ning strike a...

Page 8: ...ting system using UV resistant cable ties Protect exposed cables from damage by taking appropriate precautions e g placing them inside a plastic conduit Avoid exposure to direct sunlight A minimum ben...

Page 9: ...overlap the module by 13 mm to 15 mm 5 To ensure the thickness of the clamps is at least 3 mm Clamp positions are of crucial importance for the reliability of the installation the clamp centerline mu...

Page 10: ...8 8 9 92 CS6K 245M FG 245 30 3 8 09 37 4 8 61 15 1658 992 5 8 65 3 39 1 0 23 in without junction box and corner protector 23 CS6K 250M FG 250 30 4 8 22 37 5 8 74 CS6K 255M FG 255 30 5 8 35 37 7 8 87 C...

Page 11: ...305 32 7 9 33 39 9 9 91 CS6K 310MS FG 310 32 9 9 43 40 1 9 99 CS6X 290P FG 290 35 9 8 08 44 4 8 64 15 1968 992 5 8mm 77 5 39 1 0 23 in without junction box and corner protector 27 5 CS6X 295P FG 295 3...

Page 12: ...A Clamping on module long side four clamp points Mounting rails must run perpendicularly to the module long side Clamping Location Illustration Illustration A Clamping on module long side six clamp p...

Page 13: ...mp length 100 mm four clamps A 380 20 mm see illustration A Downforce load 2400 Pa Uplift load 2400 Pa VDE CSA 2 C 2 Profi clamp wide 3 8 mm clamp length 200 mm four clamps A 380 20 mm see illustratio...

Page 14: ...ngth 100 mm six clamps A 250 20 mm B 579 20 smm see illustration B Downforce load 5400 Pa Uplift load 2400 Pa VDE CSA 2 F 1 Akcome Metals Technology Suzhou Co Ltd AK EC DG End clamp AK MC DG Middle cl...

Page 15: ...i clamp wide 3 8 mm clamp length 130 mm four clamps A 440 20 mm see illustration A Downforce load 2400 Pa Uplift load 2400 Pa VDE CSA 3 C 2 Profi clamp wide 3 8 mm clamp length 250 mm four clamps A 44...

Page 16: ...1 End clamp PW CS 02 Middle clamp clamp length 100 mm six clamps A 300 20 mm B 684 20 mm see illustration B Downforce load 2400 Pa Uplift load 2400 Pa VDE CSA 3 E 4 PW CS 01 End clamp PW CS 02 Middle...

Reviews: