Installing solar photovoltaic systems requires specialized skills and knowledge. The installer assumes all risk
of injury, including risk of electric shock. Module installation should be performed only by a qualified installer.
All modules come with a permanently attached junction box and 4mm²wire. Jayu Solar can provide
customers with fitted cables for ease of installation, if desired.
When disconnecting wires connected to a photovoltaic module that is exposed to sunlight, an electric arc
may occur. Arcs can cause burns, start fires or otherwise create safety problems. Exercise caution when
disconnecting wiring on modules exposed to sunlight.
Photovoltaic solar modules convert light energy to direct-current electrical energy, and are designed for
outdoor use. Proper design of support structures is the responsibility of the system designer and installer.

Do not attempt to disassemble the module, and do not remove any attached nameplate
or components. Doing so will void the warranty.
Do not use mirrors or other hardware to artificially concentrate sunlight on the module.

Safety precautions for installing a solar photovoltaic system

Solar modules produce electrical energy when light shines on the front surface. The DC voltage may exceed 30V.
If modules are connected in series, the total voltage is equal to the sum of the individual module voltages. If
modules are connected in parallel, the total current is equal to the sum of individual module current

Keep children well away from the system while transporting and installing mechanical and electrical
components.
Completely cover the module with an opaque material during installation to keep electricity from being
generated.
Abide with the safety regulations for all other components used in the system, including wiring and cables,
connectors, charging regulators, inverters, storage batteries and rechargeable batteries, etc.
Use only equipment, connectors, wiring and support frames suitable for use in a solar electric systems.
Always use the same type of module within a particular photovoltaic system.
Modules rated for use in this application class may be used in systems operating at greater than 50V DC or
240W, where general contact access is anticipated. Modules qualified for safety through this part of
IEC61730 and IEC61730-2 and within this application class are considered to meet the requirements for
safety class

. Under normal conditions, a photovoltaic module is likely to experience conditions that

produce more current and/or voltage than reported at standard test conditions. Accordingly, the value of Isc
and Voc marked on this module should be multiplied by of 1.25 when determining component voltage ratings,
conductor current ratings, fuse sizes, and size of controls connected to the PV output.
The recommend maximum series fuse is 15A(156 module).
The modules have been evaluated for a maximum positive loading of 5400pa.

Do not wear metallic rings, watchbands, ear, nose, or lip rings, or other metallic devices
while installing or troubleshooting a photovoltaic systems.
Be sure to use appropriate safety equipment (insulated tools, insulated gloves, etc) approved
for use in electrical installations.
Application class A: meet the requirements for safety class II.

1/13

Summary of Contents for JY200P6-Ad-5

Page 1: ...cted in parallel the total current is equal to the sum of individual module current Keep children well away from the system while transporting and installing mechanical and electrical components Completely cover the module with an opaque material during installation to keep electricity from being generated Abide with the safety regulations for all other components used in the system including wiri...

Page 2: ...s Modules can not be used in other excessive and harsh environments such as hail snow sand smoke air pollution soot flammable gases near open flames and highly corrosive substances salt salt spray salt water acid rain As this will affect the module s safety and performance If the installation environment is special such as the seaside farm high humidity or wind and other large environment please c...

Page 3: ...odule type Cell quantity Dimensions mm A B C D E F H I 6 12 1956 992 50 942 1676 1176 M8 35 6 12 1956 992 40 949 1676 1176 M6 28 6 10 1650 992 35 40 50 942 1370 870 M8 35 6 10 1650 992 40 949 1370 870 M6 28 6 10 1640 992 35 40 50 942 1360 860 M8 35 156 Mono Poly silicon 6 10 1640 992 40 949 1360 860 M6 28 White 6 10 1636 992 35 40 50 942 1356 856 M8 35 6 10 1636 992 40 949 1356 856 M6 28 6 9 1482 ...

Page 4: ...inless steel Caution Guard against contact between different metals Doing so will give rise to electrochemical corrosion 2 Clamp fitting Use a certain number of clamps to fix the modules on the mounting rail The module clamps should not come into contact with the front glass and must not deform the frame Be sure to avoid shadowing effects from the module clamps The module frame is not to be modifi...

Page 5: ...5 11 14 0 5 2 2 5 3 JYXXXP6 Aa 5 6 12 1956 992 50 490 11 14 0 5 2 2 5 3 JYXXXP6 Ab 5 6 10 1636 992 50 427 11 14 0 5 2 2 5 3 156 Poly silicon JYXXXP6 Ab 5 6 10 1640 992 50 428 11 14 0 5 2 2 5 3 White JYXXXP6 Ab 5 6 10 1650 992 50 430 11 14 0 5 2 2 5 3 JYXXXP6 Ac 5 6 9 1482 992 50 396 11 14 0 5 2 2 5 3 JYXXXP6 Ad 5 6 8 1325 992 50 365 11 14 0 5 2 2 5 3 Table 2 Mechanical dimensions when modules inst...

Page 6: ...les as shown in figure 2 Use an end clamp to fix the edge module as shown in figure 1 Use hexagon screwdriver to tighten the clamp on the rail securely All clamps include bolts and flange nuts are stainless steel 1 end clamp 2 mid clamp 2 Mounting Methods Ground Mount Select the height of the mounting system that prevents the lowest edge of the modules from being covered by snow for an extended pe...

Page 7: ...me cases a special support frame may be necessary Module could be used in Fire safety Class C To maintain the corresponding fire prevention level the tilt angle should be no less than 5 in ft 127 mm 305 mm when the modules are mounted on the roof When installing the module on a roof or building do so in calm winds Installing a module during strong winds may cause accidents Pole mount When installi...

Page 8: ...o 1954381 2 When using grounding clips the grounding conductor should be inserted into the aluminum frame as shown above in Figure 2 and secured using the 8 32 set screw Then use a nut included with the Tyco grounding clip to secure the entire assembly as shown Next insert the 12 10 AWG solid un insulated ground wire into the slot of the lug see the picture and screw down the slotted screw Recomme...

Page 9: ...ot use dishwasher detergent Electrical and mechanical connections should be checked periodically by qualified personnel to verify that they are clean secure and undamaged Check the electrical and mechanical connections periodically to verify that they are clean secure and undamaged Problems should only be investigated by qualified personnel Observe the maintenance instructions for all other compon...

Page 10: ...ge or expense arising out of or in any way connected with such installation operation use or maintenance No responsibility is assumed by Jayu Solar for any infringement of patents or other rights of third parties which may result from use of the PV product No license is granted by implication or otherwise under any patent or patent rights The information in this manual is based on Jayu Solar s kno...

Page 11: ... Ab 5 40 22 9 33 32 98 8 93 295 00 18 13 JY290M6 Ab 5 39 90 9 30 32 64 8 87 290 00 17 83 JY285M6 Ab 5 39 86 9 21 32 57 8 75 285 00 17 52 JY280M6 Ab 5 39 56 9 09 32 42 8 62 280 00 17 21 JY275M6 Ab 5 38 89 9 04 32 20 8 55 275 00 16 90 JY270M6 Ab 5 38 72 8 89 32 02 8 42 270 00 16 60 JY265M6 Ab 5 38 45 8 79 31 56 8 40 265 00 16 29 JY270M6 Ac 5 36 43 9 62 30 26 8 94 270 00 18 37 JY265M6 Ac 5 36 22 9 45...

Page 12: ...46 96 9 07 37 92 8 57 325 16 75 JY320P6 Aa 5 46 76 9 00 37 69 8 49 320 16 49 JY315P6 Aa 5 46 37 8 89 37 44 8 41 315 16 23 JY310P6 Aa 5 46 07 8 83 37 21 8 33 310 15 98 JY305P6 Aa 5 45 77 8 77 36 96 8 25 305 15 72 JY300P6 Aa 5 45 46 8 71 36 71 8 17 300 15 46 JY295P6 Aa 5 45 27 8 62 36 46 8 09 295 15 20 JY295P6 Ab 5 40 52 9 41 32 96 8 94 295 18 13 JY290P6 Ab 5 40 31 9 32 32 86 8 82 290 17 83 JY285P6 ...

Page 13: ...36 01 9 22 28 95 8 81 255 17 35 JY250P6 Ac 5 35 71 9 10 28 79 8 68 250 17 01 JY245P6 Ac 5 35 40 9 02 28 57 8 58 245 16 67 JY240P6 Ac 5 35 10 8 95 28 27 8 50 240 16 32 JY235P6 Ac 5 34 82 8 88 28 11 8 37 235 15 98 JY240P6 Ad 5 35 10 8 95 28 27 8 49 240 18 26 JY235P6 Ad 5 34 79 8 88 28 05 8 38 235 17 88 JY230P6 Ad 5 34 49 8 80 27 78 8 28 230 17 50 JY225P6 Ad 5 34 28 8 69 27 54 8 17 225 17 12 JY220P6 ...

Reviews: