CamVac GV336 Operating Instructions Manual Download Page 10

Tel: 01246 571 020  Fax: 01246 571 030

Email: [email protected]

1. Safe Operation
•   Floor standing dust extractors should be positioned on a level floor. Ensure that there is 

no debris between the base of the extractor and the floor.

•   Wall mounted dust extractors, or those used with an optional wall mounting bracket, 

should be fixed to a solid block or brick wall using suitable fixings that will withstand 
the weight of the machine. If fixing to a studded wall, care should be taken to locate the 
fixings in to the studding of the wall. Plasterboard alone is not strong enough to withstand 
the weight of the machine. 

•   When wall mounting the dust extractor always consider it’s gross weight when full of 

waste in order to select the correct type of fixings.

•  Never place the dust extractor on a raised surface or workbench.
•   In all cases, position the dust extractor as close as possible to the application it is to be 

used for. 

•   It may be necessary to increase the length or reduce the diameter of the extraction hose 

to suit the application. Never over stretch the hose to make it reach. 

•   The strength of suction alone may cause the dust extractor to be pulled in the direction 

of the hose, particularly if the hose has been over stretched or if an optional wheel 
kit is fitted. Never stand directly between the dust extractor and the machine that it is 
connected to.

2. Familiarise yourself with the machine
•   If you are not thoroughly familiar with dust extractors, be aware of the inherent risks due 

to the way in which these machines work. There are moving parts inside the machine 
that can cause serious injury. Always strictly follow any safety instructions detailed in the 
manual when using, emptying or servicing the machine. 

3. Before switching the machine ‘ON’:
•   Remove the transit strap, which is used to secure the lid assembly to the drum body, 

before use. Never use the machine with this strap fitted as it is designed purely to protect 
the machine during transit.

•   Ensure that the switch of the machine is in the ‘OFF’ position before connecting or 

disconnecting the power supply.

•   Ensure that the extraction hose is securely fitted to the outlet of the dust extractor.
•   Always ensure that the cartridge and paper filter are securely and correctly positioned 

before using the dust extractor. Failure to do so will result in dust being sucked into the 
motor. Always ensure a good seal between the filter and motor enclosure.

•   Check that the drum filter is in place (certain models only) before replacing the lid of the 

machine.

•   Check that the dust collection bag (certain models only) is secure and not damaged.
If damaged, replace the collection bag before starting the machine.

Additional Health & Safety for High 
Filtration Dust Extractors

10

Summary of Contents for GV336

Page 1: ...Operating instructions GV336 2 5 4 Inlet www Version 3 0 October 2014 co uk CamVac Industrial Vacuum Cleaners Dus V Cam a Industrial Vacuum Cleaners Dus V Cam a...

Page 2: ...ee 13 14 2 5 Inlet Unpacking 15 Setting up Your Vacuum 15 Motor 15 Important Filtration 16 Parts Accessories 17 Hose Length and Accessories 17 Important 17 4 Inlet Unpacking 18 Setting up Your Vacuum...

Page 3: ...l before attempting to use the machine i Indicates an instruction that requires particular attention i Wear protective eyewear i Use respiratory protective equipment i Use suitable protective footwear...

Page 4: ...highly irritating dust which can cause a burning sensation The use of respiratory protective equipment should not be seen as an alternative to controlling the risk of exposure at source by using adeq...

Page 5: ...hat the workbench is well constructed and capable of withstanding the weight of the machine The machine should always be securely fastened to the workbench with appropriate fixings Where possible floo...

Page 6: ...e in explosive environments eg in the presence of flammable liquids gases or dust The presence of high levels of dust created by machining wood can present a risk of fire or explosion Always use dust...

Page 7: ...witch 17 Outdoor use Your machine should not be used outdoors 18 Extension cables Whenever possible the use of extension cables is not recommended If the use of an extension cable is unavoidable then...

Page 8: ...25 Connect dust extraction equipment Always use dust extraction equipment The dust extractor should be of suitable size and capacity for the machine that it is connected to and have a filtration leve...

Page 9: ...arts binding of moving parts breakage of parts and any other conditions that may affect the operation of the machine A guard or other part that is damaged should be properly repaired or replaced by a...

Page 10: ...s fitted Never stand directly between the dust extractor and the machine that it is connected to 2 Familiarise yourself with the machine If you are not thoroughly familiar with dust extractors be awar...

Page 11: ...whilst it is running Do not pick up liquids and scrap metal such as nails and filings or any combustible substance Ensure that the machine is used in a well ventilated area 5 Avoiding fires Wood dust...

Page 12: ...becomes hot during use this means the filters are blocked and need to be cleaned Any damage to the machine caused by blocked filters will not be covered under warranty 7 The elimination or control of...

Page 13: ...otice of the claim to examine the Product 1 2 3 if asked to do so by Record Power its Authorised Distributor or Authorised Dealer you return the Product at your own cost to Record Power s premises or...

Page 14: ...which has led to the claim This letter should then be sent with proof of the purchase date preferably a receipt to Record Power or its Authorised Distributor If you include a phone number or email ad...

Page 15: ...e the unit comes completely assembled it is very simple to put into operation The following steps should be taken after unpacking 1 Ensure that the elasticised drum filter is in place around the top l...

Page 16: ...The two cloth filters which are washable cold water wash should be shaken out at regular intervals The paper bag must be changed regularly to avoid clogging and consequent overheating and damage to t...

Page 17: ...are used in a wide variety of applications and guidance cannot be given which covers every eventuality If you find that you have a particular application and require either a reducer adaptor or extra...

Page 18: ...mpletely assembled it is very simple to put into operation The following steps should be taken after unpacking 1 Ensure that the elasticised drum filter is in place around the top lip of the drum 2 Re...

Page 19: ...washable cold water wash should be shaken out at regular intervals The paper bag must be changed regularly to avoid clogging and consequent overheating and damage to the motor the replacement of thes...

Page 20: ...a wide variety of applications and guidance cannot be given which covers every eventuality If you find that you have a particular application and require either a reducer adaptor or extra length hose...

Page 21: ...amVac Model To keep your Camvac working as good as new for years to come Please ensure paper filter bags are replaced after up to 20 hours of machine and the cloth filter bags are washed and dried at...

Page 22: ...ed L or coloured red The wire coloured blue must always be connected to the terminal marked N or coloured black The wire coloured green and yellow must always be connected to the terminal marked E or...

Page 23: ...L1 Black Live L2 Grey Live L 3 Blue Neutral N Green and Yellow Earth E The wire coloured brown must always be connected to the terminal marked L1 The wire coloured black must always be fitted to the...

Page 24: ...Tel 01246 571 020 Fax 01246 571 030 Email sales recordpower co uk Electrical Connection Wiring Diagrams 24 All Single Motor Machines Double Pole Twin Motor Machines PE L N M M M PE L N M M PE L N...

Page 25: ...cribed 1 Type High Filtration Dust Extractor 2 Model No GV336 2 5 4 Inlet 3 Serial No Conforms with the following directives Machinery Directive 2006 42 EC Low Voltage Directive 2004 108 EC Electro Ma...

Page 26: ......

Page 27: ......

Page 28: ...Tel 01246 571 020 Fax 01246 571 030 Email sales recordpower co uk Industrial Vacuum Cleaners Dust Extractors V Cam ac Industrial Vacuum Cleaners Dust Extractors V Cam ac...

Reviews: