Features

 

 

Idling behavior

 

The CPS-EP Series is permanently open-circuit proof. When an output 
voltage is preset it comes stable. If a load is switched suddenly, the unit 
stabilized within <1ms. An overshoot of the output voltage is irrelevant. 
 

Start behavior

 

The power supply has a start delay of 1s to stabilize all measuring circuits 
for the interface messages accurately. The power supply starts with a 
ramp (soft start) of 100ms. The output voltage does not overshoot - 
regardless of whether a load is connected or not. 
 

Galvanic isolation and insulation

 

The switching power supply is galvanically isolated between the input and 
the output. All major digital inputs and outputs of the interface are 
electrically isolated. 
 

Voltage set (Uadj) 

The output voltage of the CPS-EP power supply can be adjusted by a 
potentiometer located at the rear of the unit. The current limit is fix. The 
power supply operates data stable even at all output voltages. 

 

C Monitor (Imon) 

The power supply provides real-time monitoring of the output current. It is 
the exact and real value at the output terminals. The latency signal preset 
to the measured value is negligible since the control circuit is constructed 
completely analogously. 
 

Potentiometer Internal Control (Uadj)

 

The power supply will be set with an internal potentiometer. It is located at 
the rear of the unit. 
 

Sense Mode 

The power supply has a sense mode to compensate for voltage drops of 
2V per load line. 
 

Continuous Mode

 

The unit operates in continuous mode. In the continuous mode, the power 
supply provides constant current mode in a continuous flow and no ticker-
operation. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Current Share Bus (CS)

 

In parallel operation, the involved network components communicate with each 
other and share the total power evenly to each other. 
 

Remote Shutdown (SD) 

All CPS-EP devices have a remote shutdown (open collector or switching 
contacts). 
 

Inhibit Mode (Interlock) 

The inhibit circuit reliably prevents unintentional starting of the power supply. The 
control loop is internally locked. Since this blocking is done progressively it is 
active even when the control signal, is missing due to a cable break or temporarily 
suspend. A premature restart of the power supply is prevented. 
The inhibit input can be connected to a relay or switch. If the contact is interrupted, 
the power supply is switched off. If the contact is closed again, the power supply 
restarts.

 

 

DC and AC Fail 

By DC-fail the power supply reports that the power output is disabled. 
By AC-fail the power supply reports an AC undervoltage. Both signals have 
separate outputs. Each of them can be selected between NO and NC.

 

 

Over Voltage Protection (OVP) 

Until the abolition of the fault the device switches off. 
 

Over Current Protection (OCP)

 

The power supply provides continous current when it is overloaded. The voltage 
goes down to zero voltage.

 

 

Temperature Thermal Shutdown (OT)

 

The device has a thermal monitoring. When the temperature of the power supply 
is higher than the over temperature protection threshold, the unit shuts down and 
automatically restarts. An alarm signal is applied to the interface. 

 

Fan Failure Monitoring (FF)

 

If it comes to a fan failure or blocking, a signal is applied to the interface. The 
speed signal of the fan is monitored. Thus, even a creeping fault is detected at an 
early stage and there is a warning long sold separately in front of a fan failure. 
 

3D-HD (3D Heat Dissipation)

 

Our aligned and controlled heat dissipation design opens possibilities that are 
formerly being reserved to custom design power supplies: Steplessly hard mount 
of the CPS-EP2000/3000 power supply modules in a 3D-room. 
In practice that means that one can mount the modules into every angle 
imaginable. Our 3D heat dissipation (3D-HD) ensures optimal cooling in each 
mounting position you may consider. 
 

Design-to-Service:

 

Most recorded failures in the field concern the signal interface of a power supply. 
Camtec offers new concept of design-to-service that allows the customer easily to 
exchange the interface himself in the field. The analogue and digital interfaces 
apply plug & play self calibrating and can be used independent from the model 
CPS-i/EX/EP 2000 & 3000 Thus, system down cost is being reduced and only a 
small amount of spare parts need to be stocked by the customer. 

Summary of Contents for CPS-EP2000

Page 1: ...positions PFC 0 99 Features 3D Heat Dissipation CSB Current Share Bus Inhibit for safe interlocking Remote Shutdown Sense mode Current Monitoring 0 5V Power Good Relay DC ok Precise dynamics on load...

Page 2: ...ns call for the highest standards of safety and interference suppression The device was developed in accordance with the requirements of EN61010 1 EN61010 2 201 EN62368 1 and the EMC standards EN55032...

Page 3: ...witching contacts Inhibit Mode Interlock The inhibit circuit reliably prevents unintentional starting of the power supply The control loop is internally locked Since this blocking is done progressivel...

Page 4: ...l shutdown autorecovery 70 C outside measuring point distance 10mm Hold Up Time 30ms 230Vac mains buffering at full load Inrush Current 14 6Aeff 20 7Apeak 230Vac active electronic inrush protection no...

Page 5: ...nnected No Function 3 DGND Digital Ground 4 NC NC Not Connected No Function 5 NC NC Not Connected No Function 6 NC NC Not Connected No Function 7 FF Output Signal Fan Failure Open Collector 8 NC NC No...

Page 6: ...01 1 Tel 49 721 46596 0 Fax 49 721 46596 77 www camtec gmbh com info camtec gmbh com Subject to alterations This product is not designed to be used in applications such as life support systems wherei...

Page 7: ...ercon powercon 20 a nac3fca CON1 Push In 0 14 1 5mm AWG26 16 CON2 CON3 CON4 DC M8 200A 60 C 250Vac 20A Neutrik PowerCon 3x2 5 mm Neutrik NAC3FCA Interface pluggable Push Pull Connectors from Weidmuell...

Page 8: ...rop over long load lines The compensation amounts to a maximum of 2V per load line Under certain circumstances it can be expected to apply more complicated external interference suppression If sense i...

Page 9: ...the participating power supplies is important To prevent one of the power supplies going early into the current limitation and display error message An uneven load and thus premature aging of the part...

Page 10: ...orced Isolation of max 400Vdc and a basic isolation of max 600Vdc working voltage DC OK Relay DC Power Good The signal DC OK has potential free relay contacts changeover The contacts of CON1 Pin2 and...

Page 11: ...ues to protect the unit from operating under overload conditions also see OT thermal SD Model Value UA1 V Value IA1 A Value UA2 V Value IA2 A Pmax IA1 IA2 CPS EP2000 024 30Vdc 66 7A 24Vdc 84A 2001 201...

Page 12: ...licable to EN62368 1 Due to the dielectric strength of the internal components used only the models with an output voltage of 48Vdc and later are approved for series operation Other power supplies are...

Page 13: ...Germany P 13 19 01 2018 01 1 Tel 49 721 46596 0 Fax 49 721 46596 77 www camtec gmbh com info camtec gmbh com Subject to alterations This product is not designed to be used in applications such as lif...

Page 14: ...al Safety Factory Test Field Test Owner 48Vdc 2800Vdc Type and factory test are the manufacturer While repating damage can happen to the power supply unit For the field test owner follow the below ins...

Page 15: ...esult in injury or death Mechanics Aluminium housing IP20 Cooling is achieved via front to rear fans To ensure adequate heat dissipation 50mm to the front and 150mm blockade free distance from the dev...

Page 16: ...w camtec gmbh com info camtec gmbh com Subject to alterations This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in inju...