18
GB
Burner won’t light
Burner “pops” or blows
itself out
Excessive flare-up
Burner lights with a match,
but not with the “PIEZO”
igniter
Probable causes /
remedies
Probable causes /
remedies
Problems
Problems
- Lack of gas supply
- Regulator does not work
- Hose, valve, jet, venturi
tube or burner openings are
blocked.
- venturi tube not seated over jet
- Check gas supply
- Check hose connections
- Contact the After Sales
Service
- Grill temperature too high:
lower flame
-
If your grease pan or
cooking grates / hot plates
are greasy, clean them.
-
Faulty igniter, wire or
electrode
-
Check igniter cable
connections
- Check condition of electrode
and connection wire
- Contact the After Sales
Service
Fire at any connection
Incomplete flame around
burner
Lack of Heat
Fire behind control knob
Fire under control panel
- Leaking connection
- Turn off gas supply at
cylinder immediately
- Tighten connections and
check for leaks
- Contact After Sales Service
-
Defective or clogged
burner: relocate the venturi.
- Clogged jets: clean the
venturi
- Contact After Sales Service
- Clogged jet or venturi tube
- Contact After Sales Service
- Defective tap unit
- Turn off gas supply at
cylinder immediately
- Contact After Sales Service
- Turn off gas supply at
cylinder immediately
- Contact After Sales Service
Summary of Contents for ATTITUDE 2100 EX
Page 4: ...3 Fig 2A Fig 2B Fig 2C Fig 1 Fig 3A B C A L 30 cm H D...
Page 5: ...4 A B Fig 4A Fig 4B Fig 3B Fig 4C Fig 4D...
Page 6: ...5 A B C Fig 4E Fig 4G Fig 4F Fig 4H Fig 5 B A Fig 6 B A Fig 7...
Page 7: ...6 Fig 8 Attitude 2100 LX Attitude 2100 EX A B C...
Page 121: ...120 BG PIEZO...
Page 133: ...132 GR CY venturi venturi venturi venturi venturi venturi venturi PIEZO...