SECTION 4. SENSOR INSTALLATION
4-3
4.5 03001 RM YOUNG WIND SENTRY
WIND SET
The 03001 can be mounted directly to the mast,
or to the 019ALU Crossarm.
4.5.1 03001 MOUNTED TO THE MAST
Mount the 03001 to the mast as shown in
Figure 4.5-1.
1. Slide the crossarm mounting bracket onto
the mast. Orient the crossarm so the vane
end points north, and tighten the band
clamp (see Section 4.19 for final
calibration).
2. Attach the cup assembly to the
anemometer shaft using the allen wrench
provided.
4.5.2 03001 MOUNTED TO 019ALU CROSSARM
Mount the 03001 to the 019ALU crossarm as
shown in Figure 4.5-2.
1. Position the top of the mounting post 5"
above the 3/4" NU-RAIL and tighten the set
screws.
2. Slide the crossarm mounting bracket onto
the mounting post. Orient the crossarm so
the vane end points north, and tighten the
band clamp (see Section 4.19 for final
calibration).
3. Attach the cup assembly to the
anemometer shaft using the allen wrench
provided.
FIGURE 4.5-1. 03001 Mounted to the Mast
FIGURE 4.5-2. 03001 Mounted to
019ALU Crossarm
4.6 03101 RM YOUNG WIND SENTRY
ANEMOMETER
Mount the 03101 to the 019ALU crossarm as
shown in Figure 4.6-1.
1. Screw the mounting post into the mounting
bracket on the sensor.
2. Position the top of the mounting post 5" above
the 3/4" NU-RAIL and tighten the set screws.
3. Attach the cup assembly to the anemometer
shaft using the allen wrench provided.
FIGURE 4.6-1. 03101 RM Young Wind
Sentry Anemometer
03001
03001
Mounting Post
03101
Mounting Post
NU-RAIL
019ALU