background image

FIGURE 6-12. Tripod leg base –LM mounting brackets

FIGURE 6-13. Enclosure mount receiver

Enclosures

18

Summary of Contents for ENC 10/12

Page 1: ...Revision 02 2020 Copyright 2006 2020 Campbell Scientific Inc ...

Page 2: ...ducts to CSI CSI will return such Products by surface carrier prepaid within the continental United States of America To all other locations CSI will return such Products best way CIP port of entry per Incoterms 2010 This warranty shall not apply to any Products which have been subjected to modification misuse neglect improper service accidents of nature or shipping damage This warranty is in lieu...

Page 3: ...ping address is CAMPBELL SCIENTIFIC INC RMA _____ 815 West 1800 North Logan Utah 84321 1784 For all returns the customer must fill out a Statement of Product Cleanliness and Decontamination form and comply with the requirements specified in it The form is available from our website at www campbellsci com repair A completed form must be either emailed to repair campbellsci com or faxed to 435 227 9...

Page 4: ...g work l Wear a hardhat and eye protection and take other appropriate safety precautions while working on or around tripods and towers l Do not climb tripods or towers at any time and prohibit climbing by other persons Take reasonable precautions to secure tripod and tower sites from trespassers l Use only manufacturer recommended parts materials and tools Utility and Electrical l You can be kille...

Page 5: ...e or two 1 5 inch conduits 7 6 1 2 Enclosures with individual compression fittings 10 6 2 Attaching an enclosure to a tripod mast 12 6 3 UT6 UT10 UT20 and UT30 tower installation 15 6 4 Mounting an enclosure on a tripod leg base 17 6 5 Mounting more than one enclosure on a tripod leg 21 6 6 Pole mount 21 7 Maintenance 24 7 1 When to replace desiccant 24 7 1 1 Humidity indicator card 24 7 1 2 Optio...

Page 6: ...g kits 37 C 1 Hinged enclosure stack mounting kit overview 37 C 2 Hinged enclosure stack mounting kit installation 39 C 3 Enclosure leg stack mounting kit overview 40 C 4 Enclosure leg stack mounting kit installation 43 Appendix D Keeping insects out of the enclosure 44 Campbell Scientific regional offices 45 Table of Contents v ...

Page 7: ...a tripod or a tower Attaching an enclosure to a tripod mast p 12 The maintenance information When to replace desiccant p 24 and Resistance to weathering p 24 is also applicable to prewired enclosures Campbell Scientific also offers a variety of factory installed bulkhead antenna cables These cables provide a connector for an antenna on the outside of the enclosure used by a modem radio or a satell...

Page 8: ...nspection 3 1 Inspect packaging Upon receiving the enclosure inspect the packaging and contents for damage Claims for shipping damage must be filed with the shipping company Locate the packing slip for the order and compare the items listed on the packing slip to the items that were actually shipped Report any discrepancies to Campbell Scientific 3 2 Enclosure supply kit Each enclosure is shipped ...

Page 9: ...ks 1 6290 Phillips screwdriver 1 25745 PVC coupling FIGURE 3 1 Components of the Enclosure Supply Kit 3 3 Tools list for tripod mast enclosures and crossarms l 1 2 in and 7 16 in open end wrenches l adjustable wrench l Phillips head screw drivers medium small l Straight bit screwdrivers large medium l 30 cm 12 in torpedo level Enclosures 3 ...

Page 10: ...llows the components to be wired together in a lab environment resulting in cleaner wiring and providing easier access to wire diagrams and component documentation l Allows for the assembled system to be fully tested prior to deploying the system to the field l Shortens installation time in the field 4 2 Install the enclosure Mount the enclosure to a solid support Installation p 6 covers mounting ...

Page 11: ...5 in ENC10 12R Internal dimensions 25 4 x 30 5 x 14 cm 10 x 12 x 5 5 in Weight 4 1 kg 9 lb Entry seals option ES 1 medium 5 8 to 10 mm 0 231 to 0 394 in 2 small 3 to 7 mm 0 118 to 0 275 in ENC12 14 Internal dimensions 30 5 x 35 6 x 14 cm 12 x 14 x 5 5 in Weight 5 kg 11 2 lb Entry seals option ES 2 medium 5 8 to 10 mm 0 231 to 0 394 in 4 small 3 to 7 mm 0 118 to 0 275 in ENC14 16 Internal dimension...

Page 12: ...5 6 x 40 6 x 14 cm 14 x 16 x 5 5 in Weight 6 2 kg 13 6 lb PWENC16 18 Internal dimensions 40 6 x 45 7 x 22 9 cm 16 x 18 x 9 in Weight 7 7 kg 17 lb EU conformity link https s campbellsci com documents us compliance eudoc_ weather resistant enclosures pdf 6 Installation 6 1 Mounting equipment inside the enclosure 7 6 2 Attaching an enclosure to a tripod mast 12 6 3 UT6 UT10 UT20 and UT30 tower instal...

Page 13: ...cator Kit follow the procedure described in Door switch p 26 2 If installing the 5 inch or 9 inch DIN Rail Mounting Kit follow the procedure described in DIN rail mounting kits p 31 These kits facilitate wiring when many wires need to be connected to one terminal 3 If installing an enclosure stack mounting kit follow the procedure described in Mounting kits p 37 A stack mounting kit allows compone...

Page 14: ...ckplate and use pliers to pinch the grommet flanges together NOTE Remember to allow space for cables and cable connectors 5 If desired use the PVC coupling included with the enclosure supply kit to reduce the 1 5 inch conduit opening to 0 5 inches Route the sensor cables through the enclosure conduit to the data logger and peripheral terminal strips 6 Connect sensors and peripherals to the data lo...

Page 15: ...may not stick during extremely cold temperatures or extremely high humidity In these situations fasten the cable tie tab to the backplate using a 6 screw and grommet or run the cable tie through two of the enclosure backplate holes NOTE Refer to FIGURE 6 3 p 10 for steps 9 12 Enclosures 9 ...

Page 16: ...ight side of the enclosure 11 Place a roll of putty around the sensor cables where they enter the enclosure 12 Press the putty around the cables and into the conduit to form a tight seal FIGURE 6 3 An ENC12 14 with one 1 5 inch conduit houses a data logger and BP24 power supply Door not shown 6 1 2 Enclosures with individual compression fittings 1 If installing the optional Door Open Indicator Kit...

Page 17: ... connectors 3 Route each sensor and peripheral cable through a unique compression fitting FIGURE 6 4 p 11 FIGURE 6 4 Cable inserted into compression fitting 4 Connect sensors and peripherals to the data logger as described in the sensor and peripheral manuals 5 Strain relief the sensor wires to the data logger strain relief flanges with the 4 inch cable ties 6 Secure sensor and peripheral cables t...

Page 18: ... of the enclosure 9 Rotate each compression fitting so that the fitting clamps tightly against the sensor cable to provide a water tight seal see FIGURE 6 4 p 11 FIGURE 6 5 This ENC16 18 enclosure with the ES option houses the equipment commonly used in a GOES satellite system 6 2 Attaching an enclosure to a tripod mast The MM mount option is intended for mounting an enclosure to the mast of a tri...

Page 19: ... 2 Place the enclosure at the desired height typically 1 m 3 ft from the ground 3 Use the furnished 2 inch U bolts to secure the enclosure to the tripod mast 4 Route the 14 AWG wire from the brass tripod ground clamp to the enclosure ground lug Strip 2 5 cm 1 in of insulation from each end of the wire and insert the end of the wire into the ground lugs and tighten FIGURE 6 6 An enclosure with the ...

Page 20: ...FIGURE 6 7 This exploded view shows the components of a MM bracket FIGURE 6 8 An enclosure attached to a tripod mast Enclosures 14 ...

Page 21: ...th the TM option are shipped configured for the UT6 and UT10 towers Steps 1 through 3 of the following procedure are for configuring the bracket for attachment to a UT20 or UT30 tower When mounting to a UT6 or UT10 begin on step 4 1 Remove the bolts and nuts connecting the bracket to the enclosure 2 Slide out the flange sections so that the distance between the centers of each flange is 43 cm 17 i...

Page 22: ... 26 cm 10 25 in UT10 26 cm 10 25 in UT20 43 cm 17 in UT30 43 cm 17 in FIGURE 6 9 Enclosure brackets configured for a tower mount FIGURE 6 10 This exploded view shows the components of a TM bracket option Enclosures 16 ...

Page 23: ...enclosure to the leg base of a CM106B CM106BK CM110 CM115 CM120 CM106 or CM106K tripod An enclosure ordered with this option will be shipped with a LM mounting bracket attached to each side of the enclosure see FIGURE 6 12 p 18 and a U bolt bracket An enclosure mount receiver must also be attached to some tripods see FIGURE 6 13 p 18 Enclosures 17 ...

Page 24: ...FIGURE 6 12 Tripod leg base LM mounting brackets FIGURE 6 13 Enclosure mount receiver Enclosures 18 ...

Page 25: ...or the CM110 slide the keyhole notch in one of the upper corners of the LM mounting bracket over the extended Phillips head screw located on the tripod see A in FIGURE 6 14 p 19 The CM106B CM106BK CM106 and CM106K have mounting hooks extending from the tripod body in place of the Phillips screws see B in FIGURE 6 14 p 19 FIGURE 6 14 Upper mount location on CM110 A and CM106B B 2 One of the notches...

Page 26: ...nting bracket to a tripod The CM106K requires a user supplied 5 16 18 x 1 5 inch U bolt due to the smaller tripod leg size FIGURE 6 16 U bolt connection 4 Route the 14 AWG wire from the brass tripod ground clamp to the enclosure ground lug Strip 2 5 cm 1 in of insulation from each end of the wire and insert the end of the wire into the ground lugs and tighten Enclosures 20 ...

Page 27: ...6 Pole mount The PM mount option is intended for mounting an enclosure to a vertical pole An enclosure ordered with this option will be shipped with brackets metal bands and mounting hardware needed to secure the enclosure The metal bands are routed through the brackets and then around a vertical pole They are anchored in place using screw clamps Attach the enclosure to a vertical tube as follows ...

Page 28: ... openings in each bracket as shown in FIGURE 6 19 p 22 Use the closest set of holes for smaller poles and the farthest set of holes for larger poles FIGURE 6 19 Inserting the metal band 3 Position the enclosure on the side of the pole facing away from the equator Enclosures 22 ...

Page 29: ...the enclosure to a pole 6 Pull the strap tight around the pole to determine which hole to insert the screw clamp at the other end of the strap Insert the clamp into this hole 7 Use metal shears to remove any excess strap leaving a small amount for adjustments 8 Insert the screw threads into the screw clamp and tighten using a flathead screwdriver or nut driver 9 Repeat steps 5 8 for the lower stra...

Page 30: ...asure relative humidity inside an enclosure When the measurements exceed 35 relative humidity replace the desiccant packets Refer to the CS210 manual for sensor specifications installation procedures and programming information 7 2 Resistance to weathering Enclosures are coated to protect them from UV rays and other weathering However the outer surface of enclosures exposed to extreme weather rain...

Page 31: ...mer and white paint 1 Use a rag and possibly a solvent to clean the outside of the enclosure Solvents that can be used include rubbing alcohol a water solution of alkaline or caustic salts household cleaning products aromatic hydrocarbon solvents benzene xylene butyl acetate and glycol acetate 2 If a solvent was used carefully rinse and dry enclosure 3 Use a fine grain sandpaper to gently sand the...

Page 32: ...ts are used depends on the style of enclosure Use the following guide to determine the proper brackets a The door open indicator is mounted at the upper right corner of the enclosure If there is an offset near the edge of the enclosure door the sensor will be mounted with the brackets shown b If there is no offset near the edge of the enclosure door use the bracket shown Enclosures 26 ...

Page 33: ...corner of the enclosure Align the top of the sensor with the inside edge of enclosure as shown Do not allow the sensor to extend beyond the edge of the enclosure Using a marker mark the locations for two mounting holes to secure the sensor bracket 3 Assemble the sensor magnet with the bracket determined in step 1 Place the bracket in position so the edge of the sensor magnet does not extend beyond...

Page 34: ...al holes for the brackets from the outside of the enclosure using a 22 0 157 inch drill bit NOTE Drilling the holes in this manner will prevent the enclosure finish from cracking 6 From the outside of the enclosure insert two screws through the newly drilled holes 7 Place the assembled sensor bracket over the two screws making sure the sensor is aligned with the inside edge of the enclosure Secure...

Page 35: ...5V terminal and a Control terminal In this example for the CR1000X terminal C1 is used The example program demonstrates two methods to record data The first method maintains a schedule recording the door status at regular intervals The second method adds a record to the table only when the door is opened or closed The program also includes the option to turn on a Wi Fi connection if the CR1000X is...

Page 36: ...e DoorEvent Door_Open LastDoorState 100 Sample 1 Door_Open Boolean EndTable DataTable DoorStatus true 1 DataInterval 0 5 Min 10 Sample 1 Door_Open Boolean EndTable PROGRAM BeginProg Powers on NL241 attached to CS I O for 5 minutes on powerup IPNetPower 3 1 300 Scan 1 Sec 3 0 Measure Door switch PortGet Door_Open C1 Powers on NL241 attached to CS I O for 5 minutes if door open This section not requ...

Page 37: ...s of three spring loaded guillotine terminals that provide connection points for individual wires Up to 20 of these terminal strips may be fastened to the 5 in DIN rail mounting kit The 9 inch DIN rail bracket holds up to 36 The end plates separate the terminal strips Jumpers are used to electrically connect the terminals A cap needs to be on each end of the terminal strip assembly B 2 Installatio...

Page 38: ...rews prior to securing the DIN rail The other end of the ground wire is secured to the enclosure ground terminal FIGURE B 3 Mounting the DIN rail and ground wire 4 Determine the mounting order for the DIN rail components The order of components should provide for the simplest wiring later Avoid positioning components so wires must pass back and forth over other components It is also beneficial to ...

Page 39: ...nent then snaps into place when the component is pressed against the rail FIGURE B 4 p 33 Place end caps and separators next to components when the profiles of two adjacent components differ when a gap between two components is desired or when the last component is mounted to the DIN rail FIGURE B 5 p 34 FIGURE B 4 Mounting a DIN rail component Enclosures 33 ...

Page 40: ...c connections FIGURE B 6 p 34 FIGURE B 6 Applying labels 7 Attach wire jumpers between the DIN rail components and other equipment inside the enclosure To keep the enclosure organized wiring ducts are available to keep the loose wires gathered together FIGURE B 7 p 35 Enclosures 34 ...

Page 41: ...als on DIN rail components may be secured by screws or spring clamps To open the spring clamp insert a small flathead screwdriver as shown in FIGURE B 8 p 36 to open the terminal The wire end is inserted into the spring and then the screwdriver is removed to close the terminal Enclosures 35 ...

Page 42: ...res coming from outside the enclosure to the DIN rail components FIGURE B 9 p 36 Do not attach any voltage sources such as AC power or a solar panel until all other terminal connections have been made and verified FIGURE B 9 Attaching external wiring Enclosures 36 ...

Page 43: ...econd component to be mounted under the first This is beneficial when an enclosure nears its holding capacity of components The stack mounting kit is hinged allowing easy access to the lower component during wiring or during maintenance For example FIGURE C 1 p 37 and FIGURE C 2 p 38 show two typical uses of the stack mounting kit FIGURE C 1 Mounting a CR1000X above an AM16 32B hinge open Enclosur...

Page 44: ...ur screws FIGURE C 3 p 39 The component to be raised is mounted directly to the hinge plate using the grommets and screws The plate has the same half inch diamond grid pattern for the grommets found in Campbell Scientific enclosures This allows the raised area to be tailored to the component size FIGURE C 4 p 39 shows a fully assembled stack mounting kit without any components Enclosures 38 ...

Page 45: ... so the hinge is positioned on the left or top if mounting the kit vertically If a component is to be mounted under another and shares the same mounting holes as the leg mount the pieces in the following order backplate grommet leg component screw 3 Install the lower component onto the backplate using screws and grommets Connect any required wiring 4 Insert grommets into the hinge plate where requ...

Page 46: ...Stack Mounting Kit is used to raise a component 2 76 cm 3 in above the surface of the backplate This is beneficial when an enclosure nears its holding capacity of components Using the stack mounting kit allows one component to be stacked above another saving space in the enclosure For example FIGURE C 5 p 41 and FIGURE C 6 p 42 show a CR1000X mounted above an AM16 32B Any component mounted below a...

Page 47: ...FIGURE C 5 Exploded view of a CR1000X and AM16 32B mounted on a Stack Mounting Kit Enclosures 41 ...

Page 48: ...o legs eight grommets and eight screws FIGURE C 7 p 42 The component to be raised is mounted directly to the two legs using the grommets and screws This allows the raised area to be tailored to the component size FIGURE C 8 p 43 shows a CR1000X mounted to the legs FIGURE C 7 Contents of Enclosure Leg Stack Mounting Kit Enclosures 42 ...

Page 49: ...nd grommets If a component is to be mounted under another and shares the same mounting holes as the leg mount the pieces in the following order backplate grommet leg component screw 3 Fully wire the bottom component before proceeding 4 Insert grommets into the two legs where required for the component to be mounted on the legs 5 Place the top component in position and secure it with screws Enclosu...

Page 50: ...revent fire ants wasps spiders and other insects from nesting CAUTION The fumes of moth balls or crystals could be hazardous Therefore enclosures that contain moth balls or crystals should be opened in a well ventilated area 2 Put animal ear tags in the enclosure Apparently some ear tags are treated with an insecticide Talk with personnel in an agricultural store to determine the best ear tag for ...

Page 51: ...ncennes France Phone 0033 0 1 56 45 15 20 Email info campbellsci fr Website www campbellsci fr Germany Location Bremen Germany Phone 49 0 421 460974 0 Email info campbellsci de Website www campbellsci de India Location New Delhi DL India Phone 91 11 46500481 482 Email info campbellsci in Website www campbellsci in South Africa Location Stellenbosch South Africa Phone 27 21 8809960 Email sales camp...

Reviews: